Why Choose the Bently Nevada 190501-04-00-CN Velomitor CT Velocity Transducer?
When unexpected machinery vibrations threaten uptime and safety, the Bently Nevada 190501-04-00-CN Velomitor CT Velocity Transducer delivers precise, reliable measurements. This rugged sensor is engineered for continuous vibration monitoring in demanding industrial environments, helping you detect faults early and avoid costly downtime.
Product Overview
The Bently Nevada 190501-04-00-CN is a Velomitor CT Velocity Transducer designed for accurate velocity measurements. It features a sensitivity of 3.94 mV/mm/s (100 mV/in/s) ±5% and a frequency response from 3.0 Hz to 900 Hz (180 to 54,000 cpm) ±1.0 dB. Built with a 316L stainless steel case and a MIL-C-5015 connection interface, this transducer withstands harsh conditions. It includes a stud M6x1 with 3/8-in 24 adapter mounting hardware option and is made in the U.S.A.
Technical Specifications Breakdown
- Sensitivity: 3.94 mV/mm/s (100 mV/in/s) ±5% ensures consistent output for accurate vibration analysis.
- Frequency Response: 3.0 Hz to 900 Hz (180 to 54,000 cpm) ±1.0 dB covers a wide range of rotating machinery speeds.
- Operating Temperature: -40°C to +85°C (-40°F to +185°F) allows reliable performance in extreme environments.
- Case Material: 316L stainless steel provides excellent corrosion resistance.
- Intrinsic Safety Approvals: Ex ia IIC T4 and Ex nL IIC T4 for hazardous area installations per drawing 167536.
Industry Applications
This transducer excels in monitoring critical rotating equipment such as turbines, compressors, and pumps. In a petrochemical plant, its high sensitivity and wide frequency range detect early bearing wear and imbalance. The 190501-04-00-CN's rugged construction and intrinsic safety ratings make it ideal for hazardous locations, reducing the risk of catastrophic failures.
Installation & Setup Guidance
Mount the transducer using the provided stud M6x1 with 3/8-in 24 adapter. Apply a mounting torque of 4.5 N-m ± 0.6 N-m (40 in–lbf ± 5 in-lbf). The sensor can be mounted at any angle. Connect via the 2-pin 316L stainless steel MIL-C-5015 connector. Ensure cable length does not exceed 305 metres (1,000 ft.) of part number 02173006 cable to maintain signal integrity. For hazardous area installations, follow drawing 167536.
Maintenance & Reliability
Periodically inspect the transducer and cable for physical damage. Verify output bias voltage (10.1 Vdc ± 1.0 Vdc) during routine checks. The internal electronics are isolated from the case, reducing ground loop issues. With a shock limit of 5000 g pk and 100% condensing humidity tolerance, this sensor delivers long-term reliability in tough conditions.
Compatibility & Integration
The 190501-04-00-CN integrates seamlessly with Bently Nevada monitoring systems. Its dynamic output impedance (<400 Ω typical) and broadband noise floor (0.229 mm/s pk) ensure clean signals for data acquisition. The MIL-C-5015 interface simplifies connection to compatible cabling and junction boxes.
Selection Guide & Purchasing Advice
Before ordering, verify that the 190501-04-00-CN meets your application's sensitivity and frequency requirements. Confirm intrinsic safety approvals match your area classification. SpareTechPLC stocks this transducer and can assist with availability and replacement options. Contact us to confirm lifecycle status and ensure compatibility with your existing system.
Frequently Asked Questions
What is the sensitivity of the 190501-04-00-CN?
The sensitivity is 3.94 mV/mm/s (100 mV/in/s) ±5%.
What is the operating temperature range?
It operates from -40°C to +85°C (-40°F to +185°F).
Is this transducer intrinsically safe?
Yes, it has Ex ia IIC T4 and Ex nL IIC T4 approvals per drawing 167536.
What is the maximum cable length?
Up to 305 metres (1,000 ft.) of part number 02173006 cable without signal degradation.
What mounting hardware is included?
It includes a stud M6x1 with 3/8-in 24 adapter.