Technical Specifications Breakdown
Key parameters for the 31000-16-10-00-162-00-02 are listed below for quick reference:
| Feature | Specification |
|---|---|
| Probe Option | 16 = 3300 XL 8 mm probe |
| Probe Cable Length | 10 = 1.0 in |
| Standoff Adapter | 00 = No standoff adapter |
| Probe Penetration | 162 = 16.2 in |
| Fittings Option | 00 = Without fittings |
| Mounting Thread | 02 = 3/4-14 NPT |
| Protection Ratings | Type 4X (CSA), IP66, CENELEC EN50014 |
| Housing Material | Glass-reinforced PPS thermoplastic with conductive fibers |
| Sleeve Material | AISI 304 stainless steel |
| Outer Sleeve & Exterior Screws | AISI 303 stainless steel |
| O-Ring Material | Neoprene |
| Temperature Rating | -51°C to +105°C (-60°F to +221°F) |
| Weight | 1.2 kg (2.6 lb) typical |
Application Versatility in Rotating Machinery
This housing is designed for use with 3300 XL 8 mm probes in applications such as:
- Steam and gas turbines: Reliable shaft vibration monitoring in high-temperature zones up to 105°C.
- Compressors and pumps: Sealed construction prevents ingress of hose-directed water (IP66, NEMA 4X), ensuring uptime in washdown areas.
- Motors and generators: The 16.2-inch probe penetration allows deep insertion into bearing housings for accurate radial vibration measurement.
Installation and Setup Guidance
When installing the 31000-16-10-00-162-00-02, follow these engineering best practices:
- Mounting: Use the 3/4-14 NPT mounting thread option. If a standoff adapter is required, this thread is mandatory.
- Torque: Apply 29.4 N·m (260 in·lb) to the retaining nut for proper sealing.
- Sealing: The housing seals against hose-directed water but is not designed for internal or external pressure. Probes are not pressure tested before shipment. Contact the custom design department if pressure seal testing is needed.
- Cable routing: Ensure the 1.0-inch probe cable is properly secured to avoid strain on the connector.
Maintenance and Reliability
Regular inspection of the O-ring and sealing surfaces is recommended to maintain the IP66 and Type 4X integrity. The Neoprene O-ring should be checked for cracks or compression set during scheduled outages. The stainless steel components require minimal maintenance but should be cleaned if exposed to aggressive chemicals. The housing impact strength ensures long-term durability in high-vibration environments.
Robust Protection for Critical Vibration Monitoring
Industrial rotating machinery demands reliable vibration monitoring to prevent catastrophic failures. The Bently Nevada 31000-16-10-00-162-00-02 proximity probe housing assembly provides a sealed environment for 3300 XL 8 mm probes, ensuring accurate data transmission even in the harshest conditions. This component is engineered to seal differential pressure between the probe tip and the housing main body, maintaining measurement integrity.

Engineered for Extreme Environments
This housing is built to withstand the toughest conditions. The glass-reinforced PPS thermoplastic with conductive fibers provides electrostatic dissipation for hazardous areas, meeting CENELEC EN50014 standards. The stainless steel sleeve and retaining chain (AISI 304) and outer sleeve/screws (AISI 303) resist corrosion and mechanical wear.

Compatibility and Integration
This housing is specifically designed for the 3300 XL 8 mm probe series. The Viton O-ring internal to the probe case and the Neoprene O-ring between sleeve and housing provide a dual-seal system for reliable operation.
Selection Guide and Purchasing Advice
When selecting a replacement or new housing, verify the probe option, cable length, and penetration depth match your application. The 31000-16-10-00-162-00-02 is a standard configuration with no standoff adapter and no fittings. For customized options, contact AutoDCSTech. Please verify current lifecycle status and availability with AutoDCSTech before ordering.
Troubleshooting and Common Issues
- Water ingress: If the housing fails IP66 testing, inspect the O-rings and retaining nut torque. Replace damaged O-rings.
- Signal degradation: Check the probe connector and cable for damage. Ensure the 1.0-inch cable is not pinched.
- Mounting thread damage: Use anti-seize compound on the 3/4-14 NPT threads to prevent galling in stainless steel.
Availability & Condition at AutoDCSTech
| Part Number | 31000-16-10-00-162-00-02 |
|---|---|
| Availability | In Stock |
| Condition | New |
| Warranty | One Year |
| Origin | US |