Technical Specifications Breakdown
Key parameters for the 330103-00-08-10-02-05 are listed below for quick reference:
| Feature | Specification |
|---|---|
| Product Type | 3300 XL 8 mm Proximity Probe |
| Part Number | 330103-00-08-10-02-05 |
| Unthreaded Length Option | 0 mm |
| Overall Case Length Option | 80 mm |
| Total Length Option | 1.0 meter (3.3 feet) |
| Connector Type | Miniature coaxial ClickLoc connector, standard cable |
| Agency Approvals | CSA, ATEX, IECEx |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 stainless steel (SST) |
| Probe Case Thread | M10 x 1, max thread engagement 15 mm |
| Nominal Probe DC Resistance (1.0 m) | 7.59 ± 0.50 Ω |
| Linear Range | 2 mm (80 mils), from 0.25 to 2.3 mm (10 to 90 mils) |
| Recommended Gap Setting (Radial Vibration) | -9 Vdc [approx. 1.27 mm (50 mils)] |
| Operating Temperature (Standard Probe) | -52°C to +177°C (-62°F to +350°F) |
| Extended Temperature Range (Probe Tip) | -52°C to +218°C (-62°F to +425°F) |
| Extended Temperature Range (Cable/Connector) | -51°C to +260°C (-60°F to +500°F) |
| Probe Weight | 323 g/m (11.4 oz) |
| Maximum Probe Case Torque (Standard forward mounted) | 33.9 N•m (300 in•lbf) |
| Recommended Probe Case Torque (Standard forward mounted) | 11.2 N•m (100 in•lbf) |
| Maximum Probe Case Torque (First three threads) | 22.6 N•m (200 in•lbf) |
| Recommended Probe Case Torque (First three threads) | 7.5 N•m (66 in•lbf) |
Industrial Applications for Reliable Machinery Protection
The 2 mm linear range and -9 Vdc gap setting ensure accurate readings for early fault detection. With CSA, ATEX, and IECEx approvals, the 330103-00-08-10-02-05 is suitable for hazardous area installations (Class I, Zone 0 and Zone 2 environments). The PPS tip and stainless steel case provide durability in high-temperature and corrosive conditions.

Installation and Setup Guidance
Proper installation is essential for accurate measurements. Use field wiring of 0.2 to 1.5 mm² (16 to 24 AWG) with a 3-conductor shielded triad cable. Maximum field wiring length between the Proximitor Sensor and monitor is 305 meters (1,000 feet). For standard forward mounting, apply a recommended torque of 11.2 N•m (100 in•lbf) to the probe case, and 7.5 N•m (66 in•lbf) for the first three threads. Ensure the M10 x 1 thread engagement does not exceed 15 mm.
Maintenance and Reliability
Periodically inspect the probe and cable for physical damage or contamination. Avoid exposing the probe to temperatures below -34°C (-30°F) to prevent premature failure of the pressure seal. The probe is designed to seal differential pressure between the tip and case using a Viton O-ring; it is not pressure tested before shipment. For applications requiring pressure seal verification, contact the custom design department.
Precision Vibration Monitoring with the 3300 XL 8 mm Proximity Probe
For rotating machinery protection, accurate vibration measurement is critical. The Bently Nevada 330103-00-08-10-02-05 3300 XL 8 mm Proximity Probe delivers reliable data for predictive maintenance and machine health monitoring. Designed for harsh industrial environments, this probe offers a linear range of 2 mm (80 mils), starting at approximately 0.25 mm (10 mils) from the target. The recommended gap setting for radial vibration is -9 Vdc, corresponding to about 1.27 mm (50 mils).

Compatibility and Integration
The 330103-00-08-10-02-05 integrates with Bently Nevada 3300 XL Proximitor Sensors and monitoring systems. It supports both intrinsically safe (with zener barriers per drawing 141092 or galvanic isolators) and non-incendive field wiring configurations (per drawing 140979). The miniature coaxial ClickLoc connector simplifies field installation.
Selection Guide and Purchasing Advice
When selecting a proximity probe, consider cable length, thread type, and agency approvals. The 330103-00-08-10-02-05 offers a 1.0 meter cable, M10 x 1 thread, and CSA/ATEX/IECEx certifications. For pricing and availability, contact AutoDCSTech. Please verify current lifecycle status and availability with AutoDCSTech before ordering.
Troubleshooting and Common Issues
If readings are erratic, check the probe resistance (should be 7.59 ± 0.50 Ω for 1.0 m length). Verify field wiring connections and ensure the gap is set to approximately -9 Vdc. Inspect the target surface for damage or debris. For high-frequency signal rolloff, refer to frequency response graphs in the manual when using longer field wiring.
Availability & Condition at AutoDCSTech
| Part Number | 330103-00-08-10-02-05 |
|---|---|
| Availability | In Stock |
| Condition | New |
| Warranty | One Year |
| Origin | US |