Product Description

Technical Specifications Breakdown

Key parameters for the 1756-IM16I are listed below for quick reference:

Feature Specification
Module Type Isolated Digital Input Module
Inputs 16 Individually Isolated Inputs
Input Voltage 240 Volts AC
Operating Voltage Range 159-265 Volts AC
Input Delay Time Programmable 9 or 18 milliseconds
Minimum Operating Current 5 milliamperes at 159 Volts AC, 60 Hertz
Maximum Operating Current 13 milliamperes at 265 Volts AC, 60 Hertz
Maximum Input Current, Off-State 2.5 milliamperes
Power Dissipation (Max) 5.8 Watts at 60 degrees Celsius
Removable Terminal Block(s) 1756-TBCH, 1756-TBS6H

Industry Applications

High-Voltage Motor Control Centers – The 1756-IM16I directly interfaces with 240V AC control signals from motor starters, eliminating step-down transformers and saving panel space. Each isolated channel protects the backplane from voltage transients, reducing downtime.

Packaging Lines with Multiple Voltage Zones – In facilities where 159-265V AC sensors and pushbuttons coexist, this module provides a single-point solution. The programmable delay (9 or 18 ms) allows engineers to debounce noisy signals without external timers, lowering programming effort.

Water/Wastewater Treatment Plants – Remote pump stations often use AC pilot devices. The wide operating voltage range accommodates voltage drops over long cable runs, ensuring reliable state detection and avoiding false alarms.

Figure 2: Technical layout and connection details for the Allen-Bradley 1756-IM16I industrial automation component.

Installation & Setup Guidance

Mount the 1756-IM16I into any 1756 ControlLogix chassis slot. Use either the 1756-TBCH or 1756-TBS6H 36-pin removable terminal block housing for field wiring. Ensure wiring complies with local codes for 240V AC circuits. Configure input filter times via the ControlLogix programming software to match your application's noise environment. The module supports change-of-state detection, which can reduce backplane traffic and improve scan cycle efficiency.

Maintenance & Reliability

Periodically inspect terminal block connections for tightness, as vibration can loosen screws over time. Keep the module's ambient temperature below 60 degrees Celsius to maintain the 5.8W power dissipation rating. Clean the module with a dry cloth; avoid solvents that may damage the housing. No internal calibration is required.

Cost-Effective Isolation for High-Voltage AC Inputs

Industrial automation often requires reliable signal acquisition from high-voltage AC sources, where ground loops and noise can compromise system integrity. The Allen-Bradley 1756-IM16I ControlLogix isolated input module addresses these challenges with 16 individually isolated inputs, each capable of handling 240 Volts AC nominal with an operating range of 159-265 Volts AC. This per-point isolation eliminates common-mode voltage issues, reducing the need for external signal conditioners and lowering total installed cost.

Figure 1: Front view of the Allen-Bradley 1756-IM16I industrial automation component showing its physical design and enclosure.

Compatibility & Integration

The 1756-IM16I is compatible with all 1756 ControlLogix chassis and controllers. It communicates over the ControlLogix backplane, drawing 100 milliamps at 5 Volts and 3 milliamps at 24 Volts. The module works with standard 1756 I/O configuration tools and supports user-defined input filter times for both on-to-off and off-to-on transitions.

Selection Guide & Purchasing Advice

When selecting an AC input module for your ControlLogix system, consider the isolation requirements and voltage range. AutoDCSTech stocks this module and can advise on compatible terminal blocks (1756-TBCH or 1756-TBS6H). Please verify current lifecycle status and availability with AutoDCSTech before ordering.

Troubleshooting & Common Issues

If an input does not change state, check the field wiring voltage at the terminal block. Ensure the voltage is within the 159-265V AC range and that the input delay time is set appropriately for your signal frequency (47-63 Hz). If multiple channels fail, inspect the backplane connection and power supply. For off-state leakage current up to 2.5 mA, verify that the load impedance is high enough to avoid false on-states.

· Last updated:

Availability & Condition at AutoDCSTech

Part Number1756-IM16I
AvailabilityIn Stock
ConditionNew
WarrantyOne Year
OriginUS

Frequently Asked Questions

Technical Specifications

Product Type I/O Modules
SKU / Part Number 1756-IM16I
Model 1756-IM16I
Country of Origin US
Condition New
Warranty One Year
Stock Status On Request
Instruction Manual 1783997426-Allen-Bradley_1756-IM16I_Manual

Latest News

View All →