The Bently Nevada 330190-075-00-00 is a Cable DC Resistance for industrial control and automation applications.
Bently Nevada 330190-075-00-00 is a 3300 XL Extended Temperature Range (ETR) extension cable with a 7.5 meters (24.6 feet) length option and standard cable construction. Its nominal core-to-core DC resistance is 1.65 ± 0.25 Ω, a verified value that maintenance engineers can use to confirm cable integrity during routine checks.
How Does this unit Support Reliable Signal Transmission?
Signal fidelity in a 3300 XL measurement chain depends on stable cable impedance. This unit uses a 75 Ω triaxial, perfluoroalkoxy (PFA) insulated cable. Capacitance is 69.9 pF/m (21.3 pF/ft) typical, so the extension length remains predictable for high-frequency response. Jacket-to-jacket resistance is 0.49 ± 0.10 Ω, giving a second measurable parameter for field verification.
Because the cable is rated for -52°C to +260°C (-62°F to +500°F), it suits hot-process areas where standard cable would degrade. The minimum bend radius is 25.4 mm (1.0 in), which guides routing in tight machinery housings. Connectors use gold-plated brass or gold-plated beryllium copper, and maximum connector torque is 0.565 N•m (5 in•lbf) for repeatable assembly.

What Maintenance Checks Confirm Cable Health?
Periodic DC resistance measurement is the most direct indicator of conductor or connector degradation. Compare measured RCORE against the 1.65 ± 0.25 Ω nominal and RJACKET against 0.49 ± 0.10 Ω. In addition, inspect the PFA insulation for abrasion at bend points and verify connector torque has not drifted. Since the cable weighs 34 g/m (0.4 oz/ft), support long runs to avoid strain at terminations.

How Is the Extension Cable Installed in a 3300 XL Loop?
Route the cable between the 3300 XL Proximitor Sensor and the monitor, observing the 25.4 mm (1.0 in) minimum bend radius. Field wiring accepts 0.2 to 1.5 mm2 (16 to 24 AWG), and a 3 conductor shielded triad cable with tinned field wiring is recommended. Maximum field wiring length between sensor and monitor is 305 meters (1,000 feet). For radial vibration, the recommended gap setting is -9 Vdc, approximately 1.27 mm (50 mils).
Which Approvals and Safety Ratings Apply?
this unit carries agency approval option 00, meaning approval is not required for this configuration. It complies with FCC Part 15 rules and the EMC Directive 2014/30/EU, meeting EN 61000-6-2 and EN 61000-6-4 for industrial environments. RoHS Directive 2011/65/EU applies. Functional safety ratings are SIL 2 with HFT = 0 and SIL 3 with HFT = 1. Maritime classification rules from 2019 are also referenced.
For precise matching to your 3300 XL system, contact AutoDCSTech with your exact requirements.
Availability & Condition at AutoDCSTech
| Part Number | 330190-075-00-00 |
|---|