Free shipping on all orders | +86 158 8020 0923 | [email protected]

Bently Nevada 200350 vs 200355 Accelerometers: Ordering and Cable Guide

The Bently Nevada 200350 and 200355 are two 100 mV/g case-mounted piezoelectric accelerometers that share one datasheet, 164804, but not one approval list. The 200350 carries CSA, ATEX and IECEx hazardous-area certification; the 200355 is ordered with no approvals at all. Both are documented for the Trendmaster Pro Constant Current Direct Input Card 149811-02 and the Seismic Direct Input Card 164746-01, and both use a 22 AWG two-conductor twisted shielded pair with a moisture-resistant two-socket connector. Only the 200350 appears on the 1900/65A supported-transducer list, and the datasheet explicitly says the splash-proof cable is not recommended for the 200350.

That combination decides most real orders. A buyer who treats the two models as interchangeable will eventually put an uncertified 200355 into a classified area, or order a splash-proof cable for a 200350 because the connector looks like an upgrade. This guide separates what datasheet 164804 actually says from what reseller listings imply, and it keeps the Trendmaster Pro, DSM and 1900 families in their own columns instead of blending them.

What are the Bently Nevada 200350 and 200355?

Both are general-purpose, case-mounted seismic accelerometers with a 100 mV/g nominal sensitivity, a ±50 g measurement range, a hermetically welded stainless steel case and a top-mounted two-pin MIL-C-5015 connector. The 200350 is the smaller 18 mm hex body with ±20% tolerance and hazardous-area approvals; the 200355 is the 22 mm hex body with ±5% tolerance, lower noise and no approvals.

Both contain a piezoelectric sensing element in a shear geometry and convert the charge to a differential voltage proportional to acceleration along the sensitive axis. The case is ceramic-shear, stainless steel, welded hermetic, rated IP68 and specified for 100% relative humidity, condensing, non-submerged. The mounting interface is a ¼-28 female thread on the bottom, torque 2 to 5 ft-lb (2.7 to 6.8 N-m), and the connector is on top.

  • Operating temperature: -54 °C to +121 °C (-65 °F to +250 °F) for both models.
  • Shock survivability: 5,000 g peak for both models.
  • Excitation: 18 to 28 VDC, constant current 2 to 20 mA, output bias 8 to 12 VDC.
  • Electrical isolation to case: greater than 108 ohms.
  • Source: Baker Hughes, 200350 and 200355 Accelerometers Datasheet 164804 Rev. T.

Is 164804 a part number or a datasheet?

164804 is the datasheet number for the 200350 and 200355 Accelerometers, not an orderable sensor. Baker Hughes lists it as “200350 and 200355 Accelerometers Datasheet – 164804,” and older revisions carry it as document part number 164804-01. The accelerometers themselves are ordered as 200350-AA-BB-CC or 200355-AA-BB-CC, where AA is the mounting stud, BB the sensitivity tolerance and CC the approval.

A listing that offers to sell you a “164804 accelerometer” is miscoded. The number identifies a 14-page document, currently Rev. T, that covers both sensor models plus their mounting studs, adhesive kits, magnetic base and cable options. The distinction matters at quote time: the datasheet number tells you which document the seller is reading, while the order code tells you which physical part ships.

The document also names the supporting literature: 168303 for the accelerometer user guide, 162411 for the Trendmaster Pro System User Guide, 149831 for the Trendmaster DSM datasheet and 149823 for the Trendmaster DSM User Guide.

200350 vs 200355: what actually changes?

The electrical interface is the same: 100 mV/g, ±50 g, 18 to 28 VDC excitation, 2 to 20 mA constant current and a differential output. The 200355 buys ±5% sensitivity tolerance, a 0.2 Hz low-frequency limit, 50 µg noise and ≤5% transverse sensitivity; the 200350 keeps ±20%, 0.5 Hz and 350 µg but adds CSA, ATEX and IECEx approvals.

Parameter 200350 200355
Sensitivity 100 mV/g ±20% (10.2 mV/m/s² ±20%) 100 mV/g ±5% (10.2 mV/m/s² ±5%)
Frequency range, ±3 dB 30–600,000 cpm (0.5–10,000 Hz) 12–600,000 cpm (0.2–10,000 Hz)
Measurement range ±50 g ±50 g
Transverse sensitivity ≤7% ≤5%
Mounted resonant frequency 1,500 kcpm (25 kHz) 1,250 kcpm (20.8 kHz)
Broadband electrical noise, 1–10 kHz 350 µg (3,434 µm/s²) 50 µg (491 µm/s²)
Output bias voltage 8 to 12 VDC 8 to 12 VDC
Excitation 18 to 28 VDC, 2 to 20 mA 18 to 28 VDC, 2 to 20 mA
Settling time, within 1% of bias ≤2.0 s ≤5.0 s
Output impedance <150 ohms <100 ohms
Discharge time constant ≥0.3 s ≥0.8 s
Hex size / height / weight 18 mm (11/16 in) / 42.4 mm / 51 g 22 mm (7/8 in) / 52.3 mm / 94 g
Housing and sensing Stainless steel, welded hermetic, ceramic shear Stainless steel, welded hermetic, ceramic shear
Enclosure rating IP68 IP68
Operating temperature -54 °C to +121 °C -54 °C to +121 °C
Humidity 100% relative, condensing, non-submerged 100% relative, condensing, non-submerged
Mounting ¼-28 female, 2 to 5 ft-lb ¼-28 female, 2 to 5 ft-lb
Connector 2-pin MIL-C-5015, top 2-pin MIL-C-5015, top
Hazardous-area approvals CSA, ATEX, IECEx with option 01 None; option 00 only
Recommended cable length 104 ft (31 m) at 50 g, 10 kHz, 200 pF/m 104 ft (31 m) at 50 g, 10 kHz, 200 pF/m

The practical read: the 200355 is the quieter, wider-band, tighter-tolerance unit, and the 200350 is the certified unit. If the machine runs slowly and you need the 0.2 Hz floor or the 50 µg noise floor, the 200355 is the model the datasheet supports. If the installation is in a classified area, the 200355 order code has no approval block to select, so the 200350 with suffix 01 is the only one of the pair that carries the certification.

Which systems accept the 200350 and 200355?

Both models are documented for the Trendmaster Pro Constant Current Direct Input Card 149811-02 and Seismic Direct Input Card 164746-01. The Trendmaster DSM compatibility table lists the 200350 as a two-wire current-mode sensor with a 305 m cable limit; the 1900/65A lists the 200350 under acceleration, while the 1900/27 lists neither model, only the 200150 and 190520.

System or input card 200350 200355 Documented basis
Trendmaster Pro Constant Current Direct Input Card 149811-02 Yes Yes Datasheet 164804 Rev. T, description
Seismic Direct Input Card 164746-01 Yes Yes Datasheet 164804 Rev. T, description
Trendmaster DSM, Constant Current Direct Input Card 149811-02 Yes Not listed DSM datasheet 149831-01 Rev. U
1900/65A general purpose equipment monitor Yes Not listed 1900/65A supported transducers
1900/27 vibration monitor No No 1900/27 accepts 200150 and 190520

The DSM table is the place where buyers get caught. It lists the 200350 by name alongside the 330500, 330525 and 190501, specifies a 2-wire current-mode sensor and a 305 m (1,000 ft) maximum transducer cable length, and supplies -24 VDC at a 3.3 mA bias current. The 200355 is not in that table. It shares the same 100 mV/g two-wire interface and is named for the same Trendmaster Pro direct-input cards, but “same interface” is not the same as “listed for this DSM.” Treat the 200355 on a DSM as an application question for Bently support, not as a published compatibility.

The 1900 family splits the same way. The 1900/65A lists the 200350 under both Acceleration and Reciprocating Acceleration. The 1900/27 is a single-channel monitor that accepts the 200150 and 190520 accelerometers, so neither the 200350 nor the 200355 belongs on it.

What cable does Bently Nevada specify?

Bently’s standard cable is a 22 AWG two-conductor twisted shielded pair with a two-socket moisture-resistant female connector at one end and terminal lugs at the other. The unarmored 9571 is ordered from 2 to 99 ft, the armored 84661 from 3 to 99 ft, and the splash-proof CB2W100 from 15 to 250 ft.

Read the moisture wording carefully. The datasheet calls the connector moisture-resistant; it does not describe the jacket or the cable assembly with that term. If a washdown or high-humidity point needs more than the standard connector and lugs, the document points to the splash-proof cable family — except on the 200350, where it explicitly does not.

Cable option Order code Length range Notes from datasheet 164804 Rev. T
Standard, no armor 9571-AA 2 ft minimum to 99 ft maximum, 1 ft increments 22 AWG 2-conductor twisted shielded pair; 2-socket moisture-resistant female connector; terminal lugs. Standard lengths include 6, 8, 10, 12, 15, 17, 20, 25, 30, 33, 50 and 99 ft.
Standard, armored 84661-AA 3 ft minimum to 99 ft maximum, 1 ft increments Same cable construction in an armored version; same standard length list.
Splash-proof CB2W100-AAA 15, 32, 64, 112, 125, 150, 200 or 250 ft Not recommended for the 200350 accelerometer.

Non-standard and custom lengths can be ordered at additional cost. Above the standard range, the sensor datasheet gives one recommended limit: 104 ft (31 m) assuming 50 g maximum vibration, 10 kHz and 200 pF/m cable capacitance, with a direction to contact Bently Nevada Technical Support for longer runs. That is a sensor-level recommendation. The DSM card separately publishes a 305 m (1,000 ft) maximum for compatible transducers. Do not read the card limit as permission to run a 200350 at 1,000 ft without checking capacitance; the two numbers answer different questions.

Why is splash-proof cable not recommended for the 200350?

Datasheet 164804 Rev. T states plainly: “The Splash proof cable is not recommended for the model 200350 accelerometer.” It gives no reason. The note sits in the Cables section and names the 200350 only; the 200355 is not covered by it. For a washdown point on a 200350, specify 9571 or 84661 and confirm the sealing approach with Bently support.

Two boundaries keep that sentence from being over-read. First, it is a recommendation against, not a prohibition, and the document does not explain whether the issue is connector geometry, sealing, capacitance or something else. Second, it is model-specific: the same Cables section offers the CB2W100 splash-proof family without attaching the restriction to the 200355.

What a buyer should do with it is simpler than the ambiguity suggests. If the order is for a 200350, do not add CB2W100 to the bill of materials on the assumption that more sealing is better. Order the standard 9571 or the armored 84661, protect the connector at the installation level, and put the washdown question to Bently Technical Support in writing before the cable is cut to length.

How do the ordering codes work?

Both models use a three-block suffix: 200350-AA-BB-CC or 200355-AA-BB-CC. AA selects the mounting stud or base, from a ¼-28 stainless stud through M6 and M8 adapters to adhesive studs and a magnetic base kit; BB is tolerance and CC is approval. The 200350 offers approval 01 for CSA, ATEX and IECEx; the 200355 offers only 00, no approvals.

Code block 200350 option 200355 option
AA 00 ¼-28 stainless steel stud with brass tip, 0.5 in ¼-28 stainless steel stud with brass tip, 0.5 in
AA 01 ¼-28 to M6 x 1.00, stainless steel ¼-28 to M6 x 1.00, BeCu
AA 02 ¼-28 to M8 x 1.25, stainless steel ¼-28 to M8 x 1.25, BeCu
AA 09 No mounting stud No mounting stud
AA 10 ¼-28 adhesive stud mount ¼-28 adhesive stud mount
AA 11 M6 x 1 adhesive stud mount M6 x 1 adhesive stud mount
AA 12 M8 x 1.25 adhesive stud mount M8 x 1.25 adhesive stud mount
AA 13 Magnetic base kit Magnetic base kit
BB 00 100 mV/g ±20% 100 mV/g ±5%
CC 00 No approvals No approvals
CC 01 CSA, ATEX, IECEx Not offered

Note the material difference inside the same code. AA 01 and AA 02 are stainless steel on the 200350 and beryllium copper on the 200355. That is not a cosmetic substitution; order the stud by the code that matches the sensor you are buying.

Mounting accessories are shared across the pair: 164373 for the ¼-28 stud, 164372 for M6 x 1, 167559 for M8 x 1.25, and 286244 for the magnetic base with mounting stud. The adhesive kits ship with two threaded studs, two mounting pads, two-part acrylic adhesive, a scouring pad and an alcohol wipe, with a 24-hour cure and a -55 °C to +121 °C range. The magnetic base has a 35 lbf pull and is intended for flat or curved surfaces.

What are the installation and environmental limits?

Both sensors are IP68, welded-hermetic stainless steel with a ceramic shear element, rated for 100% condensing humidity without submersion, -54 to +121 °C and 5,000 g shock. Mount them on a ¼-28 female thread at 2 to 5 ft-lb on the bearing housing or casing, and never apply negative excitation voltage to a 200350.

The negative-excitation caution is a separate safety note in the 164804 text: “Do not use sensor part number 200350 for negative excitation voltage (-Vex).” It sits next to the general warning that operation outside the specified limits produces false readings or loss of machine monitoring. If your input card can be configured for negative excitation, verify the configuration before the sensor is connected.

Mounting location matters as much as the sensor. The datasheet notes that a casing measurement only works when the machine actually transmits rotor vibration to the bearing housing or casing, and that improper installation can reduce amplitude and frequency response or generate false signals. Both models use the same ¼-28 female thread and torque window, so the mounting decision is about location and surface preparation, not about which of the two sensors you picked.

What should a buyer verify before ordering?

Verify four fields, in this order: the full order code including the mounting suffix, the approval block, the system input card, and the cable length with its connector. A 200355-xx-00-00 has no hazardous-area certification, so it cannot substitute for a 200350-xx-00-01 in a classified area; Bently’s datasheet also does not recommend splash-proof cable on a 200350.

Start with the asset record, not the catalog. The existing sensor’s full suffix tells you the stud, the tolerance and whether the site relied on an approval. Then check the input card: a Trendmaster Pro or DSM constant-current card expects a two-wire current-mode sensor, while the 1900/27 expects a different accelerometer family altogether. Finally, measure the actual cable run and compare it with the 104 ft recommendation and the capacitance assumption behind it.

For current listings, see the Bently Nevada 200350 accelerometer product listing, the 200355-01-00-00 accelerometer listing, and the wider sensors and instrumentation catalog. Related Trendmaster hardware is listed under the Trendmaster Pro enveloping accelerometer and the low-frequency Trendmaster Pro accelerometer. For the broader line, use the Bently Nevada parts catalog and the Bently Nevada parts and modules guide; pricing and lead time come from the quote request page.

Frequently asked questions

Can I use a 200355 on a Trendmaster DSM card that lists the 200350?

Not on the strength of the published table. The Trendmaster DSM datasheet 149831-01 Rev. U names the 200350 as a compatible two-wire current-mode sensor, and the 200355 does not appear in that list. The 200355 has the same 100 mV/g nominal sensitivity, the same 18 to 28 VDC excitation and the same 2 to 20 mA current loop, but shared electrical interface is not a documented compatibility. Ask Bently support to confirm the pairing in writing before you substitute.

Will a 200350 work on a 1900/27 vibration monitor?

No. The 1900/27 accepts the Bently Nevada 200150 and 190520 accelerometers, at 100 mV/g with a 20 g peak maximum acceleration. The 200350 is listed for the four-channel 1900/65A under Acceleration and Reciprocating Acceleration, which is a different monitor. If the installed monitor is a 1900/27, match the 200150 or 190520 family rather than forcing a 200350 onto the input.

Why does Bently say not to use splash-proof cable with the 200350?

Datasheet 164804 Rev. T says only that the splash-proof cable is not recommended for the 200350; it does not give a technical reason. The note is in the Cables section and is not repeated for the 200355. For a 200350 in a wet location, order the standard 9571 moisture-resistant-connector cable or the armored 84661, and confirm any additional sealing measure with Bently Technical Support before installation.

Sources

This article is based on the following Baker Hughes and Bently Nevada documents, reviewed on 19 November 2026. Specifications are quoted from the current datasheet revision; the 200350 and 200355 are existing products, not new releases.

  • Baker Hughes, Bently Nevada, “200350 and 200355 Accelerometers Datasheet,” 164804 Rev. T, 2025.
  • Baker Hughes, Bently Nevada, “Trendmaster Dynamic Scanning Module,” datasheet 149831-01 Rev. U, May 2014.
  • Baker Hughes, Bently Nevada, “1900/65A General Purpose Equipment Monitor,” datasheet.
  • Baker Hughes, Bently Nevada, “1900/27 Vibration Monitor,” specifications and ordering information 141486-01 Rev. D, April 2007.
  • Baker Hughes, Bently Nevada, AM Series Accelerometers product page, product resources listing for datasheet 164804.

Manufacturer reference: For official specifications, datasheets and lifecycle information, visit the Bently Nevada AM Series accelerometers resource page.

Related components

Browse by brand: Bently Nevada

More in Product Intelligence

Looking for 200350?

Browse genuine 200350 units, specifications, and pricing — or request a quote from our automation specialists.

View 200350 Products & Get a Quote →

Leave a Reply

Your email address will not be published. Required fields are marked *

Recent Products

Recent News