Honeywell 51202329-402 is a gray Series C I/O Link cable assembly with three drops on 12-inch pitch, supporting 750 KBaud redundant C300 IOTA cabling.

Contact Us
Fast Worldwide Shipping
100% Genuine Products
Warranty Included

Product Description

The Honeywell 51202329-402 is a Cable assembly for industrial control and automation applications.

What is the Honeywell 51202329-402 I/O Link Cable Assembly?

The Honeywell 51202329-402 is a passive, pre-terminated I/O Link cable assembly for Experion PKS Series C C300 Controller IOTA connections. It carries three drops on a 12-inch (305 mm) pitch and operates at 750 KBaud, providing a verified physical layer for redundant I/O Link segments.

Engineered for exact-fit installation, this gray-jacketed assembly ships as a cable pair: one Cable A with yellow label and one Cable B with green label. Both cables are required as a pair for redundant IOTAs, yet each can be ordered individually or as a set.

Figure 1: Front view of the Honeywell 51202329-402 Cable assembly showing its physical design and enclosure.

Key Specifications and Redundancy Architecture

The table below summarizes the engineering-grade parameters that define this cable assembly’s role in a Series C cabinet. Every value is extracted directly from Honeywell documentation.

  • Brand: Honeywell
  • Model: unit
  • Cable family: Series C I/O Link (IOL1), 750 KBaud
  • Jacket color: Gray
  • Number of drops/taps: 3
  • Drop pitch: 12-inch (305 mm)
  • Redundancy variant: Cable pair (one Cable A yellow + one Cable B green)
  • Built-in ports: None (passive pre-terminated cable; plugs into IOTA and IOTA drop connectors)
  • I/O Links per C300 Controller: 2 (IOL1 + IOL2), per EP03-300-511 Section 2.3.1
  • IOTA connector text symbol: IOL1A/IOL1B (IOL1, gray) or IOL2A/IOL2B (IOL2, violet), per R301.1 cable color coding table

Redundancy is not optional in Series C I/O Link architecture: Cable A and Cable B must always be installed as a pair. The yellow and green labels provide immediate visual verification during cabinet assembly and maintenance. Because the assembly is passive, it introduces no active electronics into the link, preserving signal integrity at the specified 750 KBaud rate.

Failure Mode Analysis: Why Cable Integrity Matters

In a C300 Controller cabinet, a single I/O Link supports up to 40 I/O Units at 50 ms CEE, per EP03-300-511 Section 4.0. Each I/O Link delivers 2000 Link Units/sec for Series C I/O, where one LU equals one parameter read/write per second (R301.1 Table 9). Consequently, a degraded or intermittent cable connection can disrupt parameter throughput across the entire link.

Common failure modes for passive cable assemblies include mechanical stress at drop connectors, jacket abrasion during cabinet service, and incomplete mating at IOTA headers. This unit mitigates these risks through pre-terminated construction and a fixed 12-inch drop pitch that matches the vertical spacing of redundant IOTAs. During routine maintenance, inspect each drop connector for secure seating and verify that both Cable A and Cable B remain paired at every IOTA.

Figure 2: Technical layout and connection details for the Honeywell 51202329-402 Cable assembly.

Comparison with Alternative Cabling Approaches

When specifying I/O Link cabling, engineers may encounter field-assembled harnesses or third-party cable assemblies. The table below contrasts This unit with generic alternatives based on published Honeywell data.

  • Honeywell unit: Pre-terminated, 3 drops on 12-inch pitch, 750 KBaud rated, redundant pair with color-coded labels, passive design.
  • Field-assembled cable: Requires connector termination on site; no manufacturer-verified 750 KBaud performance; redundancy pairing must be manually documented.
  • Third-party assemblies: May list contradictory specifications; not covered by Honeywell Series C documentation; connector form factor and conductor gauge often unpublished.

For engineers prioritizing engineering-grade precision, This unit eliminates termination variability and provides a documented, repeatable connection for C300 IOTA cabling.

Installation and Compatibility Notes

The assembly plugs into IOL1A/B or IOL2A/B ports on the C300 Controller IOTA and into Series C IOTAs/IOMs within a CCA. It can also be extended to another cabinet side using Honeywell extension cables, subject to the published 30 ft (9 m) extension ceiling. Supported IOTA sizes include 6-inch (152 mm), 9-inch (229 mm), and 12-inch (305 mm), per R301.1 and EP03-490-520 Section 4.

Because the cable is passive, no configuration or parameter settings are required. However, always verify that the IOTA address jumpers are set between 1 and 40, as specified in R301.1. For system-level compliance, the Series C platform is certified to EN 61326-1:2013 (EMC) and IEC/EN 61010-1 (safety/LVD); this passive cable harness ships within the certified cabinet assembly and does not carry per-cable UL/CE/CSA marking.

Procurement and Support

AutoDCSTech supplies the Honeywell unit as a current Experion PKS Series C accessory. Contact AutoDCSTech with your exact requirements for precise matching and engineering-grade verification of cable pairs, drop counts, and cabinet topology.

· Last updated:

Availability & Condition at AutoDCSTech

Part Number51202329-402
AvailabilityIn Stock
WarrantyOne Year

Written by , Sales Engineer.

Wayne is a sales engineer with 15 years of experience in the industrial automation industry.

Technical Specifications

Product Type I/O Modules
SKU / Part Number 51202329-402
Stock Status On Request
Instruction Manual 1793702979-51202329-402-datasheet

Latest News

View All →