The Woodward 5464-654 is a Discrete Output Module for industrial control and automation applications.
Woodward 5464-654 is a 32-channel discrete output module with a 5 ms update time, built for MicroNet control systems to deliver non-isolated relay driver signals from the CPU to the prime mover. The module carries a verified 32-channel count and a 5 ms update time, ensuring precise command execution in demanding industrial environments.
What distinguishes this module discrete output module?
In an era where control systems evolved from manual levers to digital precision, this module embodies that progression. It provides 32 discrete output channels, each independently controlled by CPU commands. The 5 ms update time supports responsive output changes, while the module's design eliminates potentiometers and calibration requirements. System faults are handled by turning outputs off if communications with the CPU are lost, a critical safety behavior for prime mover control.

Key technical parameters
- Number of channels: 32
- Update time: 5 ms
- System Faults: Outputs are turned off if communications with the CPU is lost.
- Manufacturer: Woodward
- Product type: Discrete Output Module
- Country of Manufacture: United States (USA)

How does this module integrate with MicroNet control systems?
The module inserts into card guides within the control's chassis and connects to the motherboard. Two screws, one at the top and one at the bottom of the front panel, secure the module. Handles at the top and bottom, when toggled outward, move the module just far enough for the boards to disengage the motherboard connectors. This module receives digital data from the CPU and generates relay driver signals that are not isolated. It interfaces with one or more Woodward Relay Modules, which provide the isolated contacts for field wiring. Each module links to a Relay module via one low density discrete cable, daisy chained to a second module via another low density cable. The relays require a separate 24 Vdc power source, which this module does not provide.
What are the application considerations for this module?
Engineers specify this module when precise discrete output control is needed for prime movers. Because the outputs are non-isolated, the relay modules provide the necessary isolation for field wiring. The 5 ms update time supports applications requiring timely output changes. The module's lack of potentiometers means no calibration is needed, reducing maintenance effort. For system faults, outputs are turned off if communications with the CPU is lost, a fail-safe behavior that protects the prime mover. The module can be replaced with another module of the same part number without modifications, simplifying spare parts management.
Contact AutoDCSTech with your exact requirements for precise matching.