Product Overview
The Allen-Bradley 1734-IE2V is a POINT I/O Analog Input Module designed for cost-sensitive remote I/O applications where small to medium I/O counts are required. With 2 single-ended, non-isolated voltage inputs and Delta Sigma conversion, this module delivers reliable signal acquisition for process variables like flow, level, pressure, and temperature. Its low power dissipation of 0.75 Watts at 28.8 Volts DC reduces operational energy costs, making it a practical choice for distributed control architectures.

Technical Specifications Breakdown
Key parameters for the 1734-IE2V are listed below for quick reference:
| Feature | Specification |
|---|---|
| Module Type | Analog Input Module |
| Inputs | 2 single-ended, non-isolated, voltage |
| Input Signal Range | 0...10V user configurable (-0.0V under, +0.5V over) ±10V user configurable (-0.5V under, +0.5V over) |
| Conversion Type | Delta Sigma |
| Absolute Accuracy | 0.1% Full Scale @ 25 °C (77 °F) |
| Data Format | Signed Integer |
| Power Dissipation | 0.75 Watts at 28.8 Volts DC |
| Thermal Dissipation | 2.5 BTU/hour at 28.8 Volts DC |
| Enclosure Type Rating | Open |
| Key Switch Position | 3 |
Industry Applications
Its 0.1% full-scale accuracy at 25 °C ensures reliable data for billing or regulatory compliance, reducing the risk of costly errors. In packaging lines, the module captures pressure and temperature signals from sensors, enabling precise control that minimizes waste and downtime. The low power dissipation of 0.75 Watts translates to lower heat buildup in enclosures, extending the life of surrounding components and cutting cooling costs.

Installation & Setup Guidance
Mount the 1734-IE2V on a DIN rail within a POINT I/O system, ensuring the key switch is set to position 3 as specified. Connect voltage signals (0...10V or ±10V) to the two single-ended inputs, observing polarity. Use the user-configurable input range to match your sensor output; the module accepts -0.0V under and +0.5V over for 0...10V range, and -0.5V under and +0.5V over for ±10V range, providing headroom for signal fluctuations. Configure the Delta Sigma conversion rate via the network adapter to balance speed and noise rejection—slower rates improve accuracy for steady signals, while faster rates suit dynamic processes. Verify module status via front-panel LEDs: steady green indicates normal operation, flashing green means commissioning is needed, and red indicates faults.
Maintenance & Reliability
The open enclosure type requires installation in a clean, dry environment free from dust and debris. Inspect the module periodically for signs of contamination or loose connections. Because the module dissipates only 2.5 BTU/hour of heat, it contributes minimal thermal stress to the cabinet, but ensure adequate ventilation around the DIN rail to prevent localized hot spots. The Delta Sigma conversion method inherently rejects high-frequency noise, reducing the need for external filtering components and lowering total system cost.
Compatibility & Integration
The 1734-IE2V is compatible with any POINT I/O network adapter, allowing seamless integration into ControlLogix, CompactLogix, or other Rockwell Automation controllers. The module generates 6 bytes of data per channel (channel data and status), which can be read as signed integers (-32,768 to +32,767). Latching alarms with configurable levels (Low, Low Low, High, High High) can be set to trigger maintenance alerts, preventing costly process excursions. The compact form factor reduces panel space requirements, saving enclosure costs.
Selection Guide & Purchasing Advice
When selecting the 1734-IE2V, confirm that your application requires 2 voltage inputs with Delta Sigma conversion and open enclosure rating. For environments with moisture or heavy dust, consider a sealed enclosure or additional protection. AutoDCSTech stocks this module and can verify current lifecycle status and availability before ordering. Contact our team to discuss volume pricing or expedited shipping for critical projects.
Troubleshooting & Common Issues
If the module status LED shows steady red, an irrecoverable fault has occurred—replace the unit to avoid data loss. A flashing red LED indicates a recoverable fault; check wiring and configuration settings. Alternating red/green flashes mean the module is running a diagnostics test; wait for completion before interpreting other indicators. If no LEDs are lit, verify that 28.8 Volts DC is present at the module. Ensure input signals stay within the specified ranges to prevent damage to the analog front end.
Availability & Condition at AutoDCSTech
| Part Number | 1734-IE2V |
|---|---|
| Availability | In Stock |
| Condition | New |
| Warranty | One Year |
| Origin | US |