Technical Specifications Breakdown
Key parameters for the 2711P-K6M20A are listed below for quick reference:
| Feature | Specification |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 2711P-K6M20A |
| Series | PanelView Plus 600 |
| Module Type | Operator Interface Terminal |
| Input Type | Keypad |
| Power Supply | 120 Volts AC |
| Communication | RS-232, USB, 2 Ethernet ports |
| Display | 5.7-inch Monochrome |
| Product Lifecycle Status | Discontinued/Obsolete |
This operator interface terminal fits in applications where reliability and simplicity are key. Consider a packaging line that requires operators to monitor machine status and adjust parameters. The 2711P-K6M20A provides a clear grayscale display and tactile keypad, ensuring quick navigation even in low-light conditions. Another example is a material handling system that uses multiple conveyors. The two Ethernet ports allow for redundant network connections or daisy-chaining to other devices, reducing wiring complexity. For food and beverage processing, the NEMA Type 12, 13, 4x, IP54, and IP65 enclosure ratings protect against dust, water, and corrosion, making it suitable for washdown areas.
Installation and Setup Guidance
When installing the 2711P-K6M20A, follow standard panel-mount procedures. Ensure the cutout dimensions match the terminal's physical size of 6.58 x 10.47 x 3.86 inches. Use the provided gasket to maintain the enclosure rating. Connect the AC power supply to the terminal's input terminals, respecting the 85 to 264 Volts AC range at 47 to 63 Hertz. The maximum AC power consumption is 60 VA. For communications, use the RS-232 port for programming or connecting to legacy devices, the USB port for data transfer, and the two Ethernet ports for network integration. Optional DH+, DH-485, or Remote I/O modules can be installed to expand connectivity. Always verify that the terminal's firmware is compatible with your application before deployment.
Maintenance and Reliability Considerations
The 2711P-K6M20A is designed for long-term operation, but periodic inspection is recommended. Check the enclosure seals and gaskets for wear, especially in high-vibration or high-moisture areas. Clean the keypad and display with a soft, dry cloth to prevent buildup. The terminal's operating temperature range is 0 to 55 degrees Celsius, and its non-operating range is -25 to 70 degrees Celsius. Relative humidity should remain between 5 and 95% non-condensing. The terminal can withstand operating shock of 15 g at 11 milliseconds and non-operating shock of 30 g at 11 milliseconds. These specifications indicate robust construction, but avoid exposing the unit to conditions beyond these limits.
Why Upgrade Your Legacy HMI Without Rewriting Your Logic?
Industrial facilities often face a common dilemma: the control system is still sound, but the operator interface is aging. When a display fails or a keypad becomes unresponsive, production stops. The Allen-Bradley 2711P-K6M20A from Rockwell Automation offers a proven path to keep your line running. This PanelView Plus 600 terminal delivers reliable monitoring and control for a wide range of machines, and it is available through AutoDCSTech.

Built for Harsh Industrial Environments
The 2711P-K6M20A is a standard PanelView Plus 600 terminal designed for demanding factory floors. Its stainless steel domed membrane keypad includes 10 programmable function keys, numeric keys, and navigation keys. Operators can use the keypad with gloved or bare fingers, which is a practical advantage in cold or dirty environments. The grayscale passive matrix (FSTN) screen measures 5.5 inches with a display area of 4.37 x 3.30 inches. It provides 32-level grayscale at 320 x 240 resolution, and the backlight is non-replaceable. A battery-backed clock timestamps critical data with an accuracy of +/-2 minutes per month. The terminal houses 64-MB RAM and 64-MB non-volatile flash memory, with 20 MB reserved for application storage.

Compatibility and Integration Options
The 2711P-K6M20A offers flexible communication options to fit into existing architectures. The built-in RS-232 port supports serial communication with PLCs and other devices. The USB port allows for easy data logging and program transfer. Two Ethernet ports enable network connectivity, either for HMI-to-PLC communication or for remote monitoring. If your system uses DH+, DH-485, or Remote I/O, you can install optional communication modules to bridge those networks. This flexibility makes the terminal a viable replacement for older PanelView models without requiring a complete network overhaul.
Purchasing Advice and Availability
Because the 2711P-K6M20A is classified as Discontinued/Obsolete, sourcing a reliable unit can be challenging. AutoDCSTech specializes in providing industrial automation parts, including legacy Allen-Bradley components. When you order from AutoDCSTech, you receive a tested product with a clear description of its condition. Before ordering, verify the current lifecycle status and availability with AutoDCSTech to ensure the unit meets your requirements. This approach minimizes downtime and keeps your production lines running smoothly.
Availability & Condition at AutoDCSTech
| Part Number | 2711P-K6M20A |
|---|---|
| Availability | In Stock |
| Condition | New |
| Warranty | One Year |
| Origin | US |