Technical Specifications Breakdown
Key parameters for the 330101-00-12-15-02-05 are listed below for quick reference:
| Feature | Specification |
|---|---|
| Product Type | 3300 XL 8 mm Probe, 3/8-24 UNF thread, without armor |
| Unthreaded Length Option | 00 - 0.0 in |
| Overall Case Length Option | 1.2 - 1.2 in |
| Total Length Option | 15 - 1.5 meter (4.9 feet) |
| Connector and Cable-Type Option | 02 - Miniature coaxial ClickLoc connector, standard cable |
| Approvals | 05 - CSA, ATEX, IECEx |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 stainless steel (SST) |
| Linear Range | 2 mm (80 mils), from approximately 0.25 mm (10 mils) to 2.3 mm (90 mils) from target |
| Incremental Scale Factor (ISF) - Standard 5 or 1 meter System | 7.87 V/mm (200 mV/mil) ± 5% including interchangeability error |
| Probe Temperature Range (Standard) | -52°C to +177°C (-62°F to +350°F) |
Industry Applications
The 8 mm diameter provides a thicker PPS encapsulation, offering enhanced robustness against physical abuse in high-vibration environments. The patented TipLoc and CableLoc designs ensure a secure bond and high pull strength (330 N / 75 lbf), reducing the risk of sensor failure during operation.

Installation & Setup Guidance
Mount the probe using the 3/8-24 UNF thread into a compatible mounting block or bracket. Ensure the target surface is clean and within the linear range (0.25 to 2.3 mm from target). For radial vibration applications, set the recommended gap to -9 Vdc (approximately 1.27 mm / 50 mils). Use field wiring of 0.2 to 1.5 mm² (16 to 24 AWG) with a 3-conductor shielded triad cable. Maximum field wiring length is 305 meters (1,000 feet) to the Proximitor Sensor.
Maintenance & Reliability
Inspect the probe and cable periodically for signs of wear or damage. The probe is designed to seal differential pressure using a Viton O-ring; avoid exposing the probe to temperatures below -34°C (-30°F) to prevent premature pressure seal failure. The probe case is made of AISI 303 or 304 stainless steel for corrosion resistance. For high-humidity environments, the probe shows less than 3% change in Average Scale Factor after 56 days at 93% humidity per IEC 68-2-3.

Compatibility & Integration
The miniature coaxial ClickLoc connector ensures a secure, quick connection. The system supports standard 5 or 1 meter cable lengths with an ISF of 7.87 V/mm ± 5%. For longer 9 meter systems, the ISF is ± 6.5%.
Selection Guide & Purchasing Advice
When selecting a probe, consider the required cable length, connector type, and environmental approvals. The 330101-00-12-15-02-05 includes CSA, ATEX, and IECEx approvals, making it suitable for hazardous locations. AutoDCSTech stocks this model and can advise on lifecycle status. Please verify current lifecycle status and availability with AutoDCSTech before ordering.
Availability & Condition at AutoDCSTech
| Part Number | 330101-00-12-15-02-05 |
|---|---|
| Availability | In Stock |
| Condition | New |
| Warranty | One Year |
| Origin | US |