Technical Specifications Breakdown
Key parameters for the 330101-29-52-10-02-00 are listed below for quick reference:
| Feature | Specification |
|---|---|
| Product Type | 3300 XL 8 mm Probe, 3/8-24 UNF thread, without armor |
| Unthreaded Length Option | 29 = 2.9 in |
| Overall Case Length Option | 52 = 5.2 in |
| Total Length Option | 10 = 1.0 meter (3.3 feet) |
| Connector and Cable-Type Option | Miniature coaxial ClickLoc connector, standard cable |
| Linear Range | 2 mm (80 mils) |
| Incremental Scale Factor (ISF) | 7.87 V/mm (200 mV/mil) ± 5% (standard 5 or 1 meter system) |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 stainless steel (SST) |
| Standard Probe Temperature Range | -52°C to +177°C (-62°F to +350°F) |
Industry Applications for the 3300 XL Probe
Typical uses include:
Turbomachinery Monitoring
In steam turbines, gas turbines, and compressors, the 330101-29-52-10-02-00 provides precise shaft vibration and position data. Its 2 mm linear range and 7.87 V/mm scale factor enable early detection of imbalance, misalignment, or bearing wear.
Pump and Motor Protection
For large pumps and electric motors, the probe’s robust stainless steel case and PPS tip withstand oil, moisture, and temperature extremes. The patented CableLoc design offers 330 N (75 lbf) pull strength, reducing cable breakage in high-vibration areas.
Gearbox Health Assessment
In gearboxes, the probe’s 8 mm diameter and thicker encapsulation provide superior resistance to physical abuse compared to smaller probes. This durability translates to lower replacement costs and higher uptime.

Installation & Setup Guidance
Proper installation is critical for accurate measurements. Follow these engineer-level recommendations:
- Thread Engagement: The probe case thread is 3/8-24. Maximum thread engagement length is 0.563 in. Do not exceed this to avoid damaging the probe or machine.
- Torque Limits: For standard forward mounted probes, maximum rated torque is 33.9 N•m (300 in•lbf); recommended torque is 11.2 N•m (100 in•lbf). For the first three threads, maximum rated torque is 22.6 N•m (200 in•lbf); recommended is 7.5 N•m (66 in•lbf).
- Gap Setting: For radial vibration, set the gap to -9 Vdc (approximately 1.27 mm or 50 mils) from the target.
- Field Wiring: Use 0.2 to 1.5 mm² (16 to 24 AWG) 3-conductor shielded triad cable. Maximum field wiring length between the Proximitor Sensor and monitor is 305 meters (1,000 feet).
Maintenance & Reliability
To ensure long-term reliability, inspect the probe and cable periodically for physical damage, especially in high-temperature or high-humidity environments. The probe is designed to seal differential pressure with a Viton® O-ring, but is not pressure tested before shipment. If your application requires a pressure seal test, contact the custom design department. Avoid exposing the probe to temperatures below -34°C (-30°F) to prevent premature pressure seal failure.

Selection Guide & Purchasing Advice
When selecting a replacement or new probe, verify that the thread type (3/8-24 UNF), unthreaded length (2.9 in), overall case length (5.2 in), and total cable length (1.0 meter) match your machine’s requirements. The 330101-29-52-10-02-00 is a standard probe without armor, suitable for most industrial environments. For applications involving oil leakage, consider the optional FluidLoc cable. Please verify current lifecycle status and availability with AutoDCSTech before ordering.
Troubleshooting & Common Issues
- Incorrect Gap Voltage: If the output voltage is not near -9 Vdc at the recommended gap, check the probe tip clearance and target material. Re-adjust the mounting position.
- Signal Noise or Drift: Verify that field wiring does not exceed 305 meters and that shielded cable is properly grounded. High-frequency signal rolloff can occur with longer wiring; refer to frequency response graphs.
- Cable Damage: Inspect the cable for cuts or kinks. The CableLoc design provides 330 N pull strength, but excessive bending near the connector can still cause failure.
- Temperature Effects: If the probe is exposed to temperatures above +177°C (+350°F), use the extended temperature range probe (rated up to +218°C for the tip). Standard probe operation above this range may degrade accuracy.
Availability & Condition at AutoDCSTech
| Part Number | 330101-29-52-10-02-00 |
|---|---|
| Availability | In Stock |
| Condition | New |
| Warranty | One Year |
| Origin | US |