The Lenze EVF9325-EVV004 is a Frequency inverter for industrial control and automation applications.
Lenze EVF9325-EVV004 is a three-phase frequency inverter from the 9300 vector series, rated 5.5 kW for a 4-pole asynchronous motor at 3 AC 400 V. Its 13.0 A nominal output current at 8 kHz chopper frequency and 150% overload for 60 s support demanding load profiles without oversizing the drive.
Key Specifications and Cost Implications
Each parameter below directly influences energy use, panel space, or maintenance effort. The supply voltage range of 3/PE AC 320 to 528 V nominal, 45 to 65 Hz, accommodates common industrial grids. An alternative DC supply of 460 to 740 V DC is also supported. The 210 W power loss figure represents continuous heat that must be removed from the enclosure, so cooling capacity and energy costs should be sized accordingly.
- Output current: 13.0 A nominal at 8 kHz chopper frequency; 19.5 A maximum for 60 s.
- Overload capability: 150% rated torque for 60 s, reducing the need to specify a larger drive for peak loads.
- Output power: 9.0 kVA nominal.
- Chopper frequency: adjustable 2, 4, 8 or 16 kHz, allowing a trade-off between acoustic noise and switching losses.
- Control modes: V/f characteristic control or sensorless vector control, selectable for different load types.
- Safety variant: V004 includes an X11 KSR relay output for safe standstill.
- Protection rating: IP20 (NEMA 1) for installation inside a controlled cabinet.
- Dimensions and weight: 350 × 135 × 250 mm, 7.8 kg.

How Does this drive Support Safe Standstill?
The V004 variant provides an X11 KSR relay output for safe standstill. This relay can be wired into a machine safety circuit to remove drive torque when the safety function is triggered. As a result, the inverter can be integrated into safety concepts without a separate external contactor for the drive output. The relay is part of the drive's terminal set, so panel wiring and component count are reduced.
What Are the Communication Options for This Frequency Inverter?
this drive includes an AIF automation interface (X1) for a pluggable fieldbus module. No fieldbus module is integrated as standard, so the exact protocol is chosen at commissioning. Supported modules include LECOM-A/B RS232/485, PROFIBUS DP, CANopen, DeviceNet, INTERBUS, and LON. A system bus CAN (X4) and an incremental encoder input (X8) are built in. This modular approach lets you match the network to the machine without replacing the drive. Integration note: wiring into a fieldbus network may require an external gateway or connection module; confirm cables and gateways with the supplier.

Installation and Environmental Considerations
Mount the inverter vertically inside a cabinet that meets the IP20 (NEMA 1) rating. The rated operating temperature is 0 to +40 °C. Above +40 °C, output current must be derated by 2.5%/°C up to +55 °C. Storage temperature is -25 to +55 °C, with transport down to -25 to +70 °C. Relative humidity should average 85 % RH without condensation (climatic class 3K3 per EN 50178). Ensure the 210 W power loss is removed by the cabinet cooling system to avoid thermal derating and reduced service life.
Maintenance and Lifecycle
Inspect the drive periodically for dust accumulation and fan operation. Because the 9300 vector series is listed in Lenze previous-products documentation and superseded by newer drive generations, verify current lifecycle status and availability with AutoDCSTech before ordering. Lenze documents a migration path to the i950 via a PROFIBUS module and L_ICIP library, but no drop-in same-order-code replacement exists.
Availability & Condition at AutoDCSTech
| Part Number | EVF9325-EVV004 |
|---|---|
| Availability | In Stock |
| Warranty | One Year |