I/O Modules PLC & I/O Modules

Honeywell TREXCFPNAWS3 AMS Trex Device Communicator with HART & Wireless

On Request
Brand: Honeywell
Product No. TREXCFPNAWS3
Model TREXCFPNAWS3
Origin US
Condition New
Warranty One Year

The Honeywell TREXCFPNAWS3 is an AMS Trex Device Communicator with HART and Foundation Fieldbus applications, wireless capability, and 3-year support.

Contact Us
Fast Worldwide Shipping
100% Genuine Products
Warranty Included

Product Description

Technical Specifications Breakdown

Key parameters for the TREXCFPNAWS3 are listed below for quick reference:

Feature Specification
Manufacturer Emerson
Product No. TREXCFPNAWS3
Product Type AMS Trex Device Communicator
Platform Base Trex Platform
Communication Module Device Communicator communication module
Applications HART + Foundation Fieldbus Applications
Power Module Type Rechargeable Li-Ion Power Module
Product Certifications No Approval
Radio Options Wireless
Support Standard Support (3 Year)
Microprocessor 800 MHz ARM Cortex A8/NXP
Memory Internal Flash 2GB NAND and 32 GB extended flash
Operating System Windows Embedded Compact 2013
Display 640 x 480 pixel
RAM 512 MB DDR3 SDRAM
Display Size 5.7 in color VGA resistive touchscreen
Battery Operating Time 8+ hours of typical use
Operating Temperature -4 to 122°F
Enclosure Rating IP54

Industry Applications

With HART and Foundation Fieldbus applications, you can configure and test valves inline, reducing downtime. The wireless capability lets you synchronize field data with AMS Device Manager automatically, improving data accuracy. The IP54 enclosure and shock-tested design (survives a 1-meter drop onto concrete) make it suitable for harsh field environments.

Figure 2: Technical layout and connection details for the Honeywell TREXCFPNAWS3 industrial automation component.

Installation & Setup Guidance

Before first use, fully charge the rechargeable Li-Ion power module. The device is intrinsically safe, so you can connect it to live loops without special permits. Use the touchscreen to navigate the Windows Embedded Compact 2013 interface. For wireless synchronization, ensure the device is within range of your AMS Device Manager network. Follow standard safety procedures when connecting to field wiring.

Maintenance & Reliability

Inspect the touchscreen and enclosure regularly for damage. Keep the device clean and dry. The battery provides 8+ hours of typical use; recharge after each shift. The device is designed to survive a 1-meter drop onto concrete, but avoid unnecessary impacts. Operating temperature range is -4 to 122°F, so avoid prolonged exposure outside this range.

Field-Ready Device Communicator for HART and Foundation Fieldbus

The Honeywell TREXCFPNAWS3 is an AMS Trex Device Communicator engineered for maintenance engineers who need reliable, on-the-spot diagnostics and configuration of smart field devices. This unit combines the base Trex platform with a Device Communicator communication module, HART + Foundation Fieldbus applications, a rechargeable Li-Ion power module, and wireless radio capability. It ships with Standard Support for three years, ensuring long-term assistance for your team.

Figure 1: Front view of the Honeywell TREXCFPNAWS3 industrial automation component showing its physical design and enclosure.

Compatibility & Integration

It supports HART and Foundation Fieldbus protocols, making it compatible with a wide range of smart transmitters, valves, and analyzers. The wireless option enables remote communication, reducing the need for physical connections.

Selection Guide & Purchasing Advice

When selecting a device communicator, consider the protocols you use (HART, Foundation Fieldbus) and the need for wireless. The TREXCFPNAWS3 covers both. It also includes 3 years of Standard Support, which is valuable for long-term reliability. AutoDCSTech offers this unit with fast shipping and expert support. Contact AutoDCSTech to verify current lifecycle status and availability before ordering.

Troubleshooting & Common Issues

If the device does not power on, check the battery charge. If the touchscreen is unresponsive, clean it with a soft cloth. For communication issues, verify the correct protocol is selected and that the device is properly connected. If wireless sync fails, check network settings and range. For persistent issues, consult the user manual or contact AutoDCSTech for technical assistance.

· Last updated:

Availability & Condition at AutoDCSTech

Part NumberTREXCFPNAWS3
AvailabilityIn Stock
ConditionNew
WarrantyOne Year
OriginUS

Frequently Asked Questions

Technical Specifications

Product Type I/O Modules
SKU / Part Number TREXCFPNAWS3
Model TREXCFPNAWS3
Country of Origin US
Condition New
Warranty One Year
Stock Status On Request
Instruction Manual 1785889369-Honeywell_TREXCFPNAWS3_Manual

Latest News