The Allen-Bradley 22C-B033N103 is a AC adjustable-frequency drive for industrial control and automation applications.
When a pump station needs precise flow control without an external PID controller, the Allen-Bradley 22C-B033N103 PowerFlex 400 AC adjustable-frequency drive delivers a built-in PID loop and 33 A continuous output at 7.5 kW (10 HP). This fan-and-pump drive accepts 200…240V AC three-phase input and provides 0…230V three-phase output.
Key specifications of the 22C-B033N103 drive
Engineers specify this model for its exact electrical profile. The table below lists verified parameters from manufacturer publications.
- Input voltage: 200…240V AC, 3-phase, ±10% tolerance, 48…63 Hz
- Output current: 33 A continuous at 45 °C and 50 °C ambient
- Output power: 7.5 kW (10 HP)
- Output voltage: 0…230V three-phase
- Isolation: one isolated analog input (–10…+10V or 4…20 mA) plus one non-isolated analog input
- Enclosure: IP20 / NEMA/UL Type Open, Frame C
- Communication: built-in RS-485 DSI supporting Modbus RTU, Metasys N2 and P1-FLN
- Overload: 110% for up to 1 min
- Efficiency: 97.5% at rated amps, nominal line voltage

How does the built-in RS-485 port simplify fan and pump integration?
This unit includes a single RS-485 DSI port on an RJ45 connector, with only pins 4 and 5 wired. It natively supports Modbus RTU, Metasys N2 and P1-FLN protocols. For Modbus RTU, the drive uses function codes 03, 06 and 16; Logic Command is register 8192 and Reference is register 8193. Network parameters such as C103 [Comm Data Rate] default to 9600 bit/s, and C104 [Comm Node Addr] defaults to 100. This native support reduces the need for external gateways in many building automation systems.
What causes overvoltage trips in fan and pump applications?
Deceleration of high-inertia fans can cause the DC bus to exceed the 405 V DC overvoltage trip threshold. The drive offers programmable stop modes including Ramp, Coast, DC-Brake, Ramp-to-Hold and S-curve. For dynamic braking, an external brake chopper is required because no internal braking transistor is published. Additionally, the drive provides 100 ms power ride-through and 0.5 s minimum logic control ride-through to maintain operation during brief supply disturbances.

Installation and environmental considerations
Mount the drive in a ventilated enclosure with a minimum volume of 5098 in.3 when used as a Manual Self-protected (Type E) Combination Motor Controller. The recommended input fuse rating is 45 A (UL Class J, CC, T or Type BS88). Ambient temperature without derating is –10…+50 °C for IP20 open enclosures. Above 1000 m altitude, derate 3% per 305 m. The drive is fan cooled and requires an atmosphere free of volatile or corrosive gas, vapors or dust.
Why specify This unit for precise pump control?
This drive combines a built-in PID loop, purge input and auxiliary motor control for up to three auxiliary motors. This unit delivers engineering-grade precision for flow and pressure regulation. Its 0.98 displacement power factor across the speed range reduces reactive current. For EN 61800-3 compliance, add the external 22-RF034-CS line filter. Contact AutoDCSTech with your exact requirements for precise matching.
Availability & Condition at AutoDCSTech
| Part Number | 22C-B033N103 |
|---|---|
| Availability | In Stock |
| Warranty | One Year |