The Allen-Bradley 25C-A011N104 is a AC adjustable-frequency drive — PowerFlex 527 for industrial control and automation applications.
When a machine builder needs a compact 2.2 kW drive that combines standard variable-speed control with integrated safety over one network, the Allen-Bradley 25C-A011N104 PowerFlex 527 AC drive is the exact answer. It delivers 11 A continuous output at 200…240V AC single-phase input, and its dual embedded EtherNet/IP ports carry both control and CIP Safety data.
What specifications define this drive drive?
This PowerFlex 527 member is rated 2.2 kW (3 HP) in both normal duty and heavy duty. Its output voltage spans 0 V to rated motor voltage on terminals T1, T2 and T3, while output frequency is programmable from 0…590 Hz. The table below lists the verified electrical and environmental parameters.
- Input voltage: 200…240V AC, 1-phase
- Input frequency: 47…63 Hz
- Continuous output current: 11 A maximum
- Output frequency: 0…590 Hz (programmable)
- Efficiency: 97.5 % (typical)
- Enclosure: IP20 NEMA/Open Type, Frame B
- Operating temperature: -20…+50 °C without derating
- Dimensions (H×W×D): 180.0 × 87.0 × 172.0 mm
- Weight: 1.6 kg

How does integrated safety and EtherNet/IP simplify machine integration?
The drive includes a hardwired Safe Torque Off input certified by TÜV Rheinland up to Performance Level e (PLe), Category 3 per EN ISO 13849 and SIL CL 3 per IEC 61508. Its response time is less than 12 ms. Because the dual embedded EtherNet/IP ports support linear, star and Device Level Ring topologies, safety and standard control data travel over the same cable. A Logix-based controller can command motion through CIP Motion instructions, and the drive is ODVA conformance tested to EtherNet/IP specifications.

Which applications suit this 2.2 kW drive?
Typical uses include conveyors, fans, pumps and simple positioning axes that require safe torque removal without separate safety relays. The 11 A output current supports motors up to 2.2 kW in heavy duty, while the 150 % overload for 60 s and 180 % for 3 s handle transient loads. For encoder-based velocity or position control, the optional 25-ENC-2 board provides a 5V/12V, 250 mA incremental encoder interface.
What should engineers verify before installation?
Confirm that the panel provides single-phase 200…240V AC supply and that the load does not exceed 11 A continuous. The drive produces leakage current above 3.5 mA AC, so the protective earthing conductor must meet local high-earthing-current regulations. Mount the Frame B unit vertically with the published clearance, and use the 25-JBAx option kit if an IP30/NEMA 1 enclosure is needed. For precise matching of options and accessories, contact AutoDCSTech with your exact requirements.
Availability & Condition at AutoDCSTech
| Part Number | 25C-A011N104 |
|---|---|
| Availability | In Stock |
| Warranty | One Year |