Technical Specifications Breakdown
Key parameters for the 1746-IM4 are listed below for quick reference:
| Feature | Specification |
|---|---|
| Module Type | Digital AC Input Module |
| Voltage Range | 170-265 Volts AC |
| Inputs | 4 |
| Backplane Current (5 Volts DC) | 35 milliamps |
| Signal Delay | 35 or 45 milliseconds |
| Off State Current | 2 milliamps |
| Applications | General Purpose 125 Volts DC Inputs |
| I/O Connection | 1746-HT and 1746-HCA |
| Step Response | 100 milliseconds in, 2.5 milliseconds out |
Industry Applications and Cost Benefits
By directly accepting 170-265V AC inputs, it eliminates external step-down transformers, reducing installation costs. The 35 ms ON signal delay and 45 ms OFF delay allow precise timing for safety interlocks, minimizing false triggers and downtime costs. For general-purpose 125V DC input applications, the module offers flexibility without additional hardware investment.

Installation and Setup Guidance
Mount the module in any 1746 I/O chassis slot. Ensure AC power is disconnected before insertion. Use 1746-HT or 1746-HCA wiring connectors for secure terminations. Verify the voltage range (170-265V AC) matches your supply to avoid damage. The module draws 35 mA from the 5V DC backplane; confirm your chassis power supply can support the total load.
Maintenance and Reliability
Inspect the module periodically for signs of overheating or loose connections. The operating temperature range of 0 to 60 °C (32 to 140 °F) at 5-95% non-condensing humidity ensures reliable performance in typical industrial environments. Storage from -40 to 85 °C (-40 to 185 °F) allows safe inventory management. The module withstands 30G shock and 2.5G vibration at 57-500 Hz, reducing failure risk in high-vibration applications.
Cost-Efficient AC Input Sensing for SLC 500 Systems
The Allen-Bradley 1746-IM4 is a SLC 500 Digital AC Input Module designed to deliver reliable input sensing while minimizing operational costs. With a voltage range of 170-265 Volts AC and 4 inputs, this module reduces the need for additional signal conditioning, lowering total system expense. Its backplane current draw of 35 milliamps at 5 Volts DC ensures minimal power consumption, directly contributing to energy savings over the system's lifecycle.

Compatibility and Integration
It uses standard 1746-HT and 1746-HCA I/O connection cables, simplifying replacement and expansion. Circuit isolation tested at 1500V AC between backplane and I/O protects sensitive electronics, lowering repair costs.
Selection Guide and Purchasing Advice
When selecting the 1746-IM4, verify your system's voltage requirements match the 170-265V AC range. For cost-conscious projects, this module reduces component count and wiring complexity. AutoDCSTech offers this module with expert support to ensure correct integration. Please verify current lifecycle status and availability with AutoDCSTech before ordering.
Troubleshooting and Common Issues
If inputs fail to register, check the AC supply voltage is within 170-265V AC. Verify wiring using 1746-HT or 1746-HCA connectors. For intermittent faults, inspect for leakage current exceeding 2 mA off-state current. Signal delays of 35 ms (ON) and 45 ms (OFF) can help diagnose timing issues in the control logic.
Availability & Condition at AutoDCSTech
| Part Number | 1746-IM4 |
|---|---|
| Availability | In Stock |
| Condition | New |
| Warranty | One Year |
| Origin | US |