I/O Modules PLC & I/O Modules

Allen-Bradley 1791-0A32 Block I/O AC Output Module Overview

On Request
Brand: Allen-Bradley
Product No. 1791-0A32
Model 1791-0A32
Origin US
Condition New
Warranty One Year

The Allen-Bradley 1791-0A32 is a discontinued Block I/O AC output module with 32 outputs, 20-132VAC range, and RIO protocol support. Ideal for high-density discrete output applications.

Contact Us
Fast Worldwide Shipping
100% Genuine Products
Warranty Included

Product Description

Product Overview

The Allen-Bradley 1791-0A32 is a high-density Block I/O AC output module designed for distributed control systems. This digital output module integrates thirty-two discrete output channels in four groups of eight, providing reliable switching of AC loads such as motor starters, solenoid actuators, indicators, and signaling devices. It supports the Remote I/O (RIO) protocol for direct communication with RIO scanners, functioning as a slave device that mimics a distributed I/O station. The 1791-0A32 is compatible with PLC-2, PLC-3, PLC-5/20, and PLC-5 controllers, making it a versatile choice for legacy automation upgrades.

Figure 1: Front view of the Allen-Bradley 1791-0A32 industrial automation component showing its physical design and enclosure.

Technical Specifications Breakdown

Key parameters for the 1791-0A32 are listed below for quick reference:

Feature Specification
Module Type Digital AC Output Module
Number of Outputs Thirty-Two (32) outputs
Channel Grouping Four (4) groups of Eight (8) channels
Operating Voltage Range 20-132 VAC
Nominal Output Voltage 120 VAC
Maximum On-state Current 50 mA per output
Surge Current 10 A for 50 ms each, repeatable every 2 sec
Output Delay Time, OFF to ON 1.0 ms at 60 Hz and 1.0 ms at 50 Hz
Output Delay Time, ON to OFF 8.3 ms at 60 Hz or 10.0 ms at 50 Hz
OFF State Leakage Current 3 mA
Mounting Orientation Vertical and Horizontal
Weight 1.00 lbs (0.45 kg)

Industry Applications

For example, in a bottling plant, the 1791-0A32 can control multiple solenoid valves for filling stations. Its four isolated groups allow independent power distribution, reducing wiring complexity. The 10 A surge current rating supports inrush loads like small motor starters without external suppression. When upgrading older PLC-2 or PLC-5 systems, this block I/O replaces bulky racks, saving cabinet space and simplifying maintenance.

Figure 2: Technical layout and connection details for the Allen-Bradley 1791-0A32 industrial automation component.

Installation & Setup Guidance

Mount the 1791-0A32 vertically or horizontally on a DIN rail or panel. Ensure ambient temperature stays between 0 and 60 °C. Connect AC power to terminals L1 (1), N (3), and GND (2). For RIO communication, wire the blue (BLU), clear (CLR), and shield (SHD) terminals on the left side. Set the I/O rack number via the switch assembly behind the front cover. Status LEDs on the front cover aid in initial verification. Always verify that the connected load does not exceed 50 mA per output continuously.

Maintenance & Reliability

Inspect the module periodically for dust accumulation and loose connections. The front cover provides access to status indicators for troubleshooting. Given its discontinued status, stock a spare unit to minimize downtime. Operate within the specified temperature range to ensure reliable switching.

Compatibility & Integration

The 1791-0A32 communicates via Remote I/O (RIO) protocol. It is compatible with scanners such as the 1771-SN (PLC-2 family), 1775-S5 (PLC-3 family), and PLC-5VME (6008-LTV). No external adapter is needed; the module includes built-in adapter functionality. It works with PLC-2, PLC-3, PLC-5/20, and PLC-5 controllers.

Selection Guide & Purchasing Advice

When selecting a replacement for a failed 1791-0A32, consider that this model is discontinued/obsolete. AutoDCSTech offers verified used and new surplus units. Verify current lifecycle status and availability before ordering. For new installations, evaluate modern equivalents from the Allen-Bradley 1734 or 5069 series for extended features and support.

Troubleshooting & Common Issues

If outputs fail to energize, check the RIO communication cable and verify the rack number setting. Use the status LEDs to identify group faults. If an output channel remains on when commanded off, measure leakage current; the module specifies 3 mA off-state leakage, which may keep sensitive loads active. Ensure the load requires at least 50 mA to switch reliably.

· Last updated:

Availability & Condition at AutoDCSTech

Part Number1791-0A32
AvailabilityIn Stock
ConditionNew
WarrantyOne Year
OriginUS

Technical Specifications

Product Type I/O Modules
SKU / Part Number 1791-0A32
Model 1791-0A32
Country of Origin US
Condition New
Warranty One Year
Stock Status On Request