I/O Modules PLC & I/O Modules

ATV610D45N4 45 kW 380-460 V Drive, 88 A Output

On Request
Product No. ATV610D45N4

Schneider Electric ATV610D45N4 variable speed drive: 45 kW normal duty, 380...460 V three-phase supply, 88 A continuous output, integrated C3 EMC filter and Modbus RTU.

Contact Us
Fast Worldwide Shipping
100% Genuine Products
Warranty Included

Product Description

What Causes Premature Drive Failures in Pump and Fan Applications?

The answer often lies in insufficient attention to input voltage tolerance, output current headroom, and isolation integrity. The Schneider Electric ATV610D45N4, part of the Easy Altivar 610 series, addresses these exact failure modes through verified electrical specifications and engineering-grade construction. This 45 kW (60 HP) normal duty drive delivers 88 A maximum continuous output current from a 380...460 V three-phase supply, with a 37 kW (50 HP) heavy duty rating at 74.5 A continuous. The integrated Category C3 EMC filter and conformal-coated electronic cards provide the isolation and environmental resilience required for demanding pump and fan installations.

Figure 1: Front view of the Schneider Electric ATV610D45N4 industrial automation component showing its physical design and enclosure.

Electrical Specifications and Isolation Parameters

The ATV610D45N4 operates from a 380...460 V AC, 50/60 Hz three-phase supply. Maximum input current is 92.9 A at 380 V and 82.7 A at 460 V under normal duty. Apparent power reaches 65.9 kVA at 460 V. The drive provides 88 A maximum continuous output current (normal duty) with 97 A transient current for 60 s. Heavy duty ratings are 37 kW, 74.5 A continuous, and 112 A transient for 60 s. Overload capability is 110% of rated current for 60 s (or 120% for 20 s) in normal duty, and 150% for 60 s in heavy duty.

Isolation is a critical parameter. The relay output supply must be Overvoltage Category II (OVC II) per IEC/EN 61800-5-1; otherwise an isolation transformer is required. Electronic cards carry protective conformal coating, supporting operation in chemically demanding environments classified 3C3 / 3S3 according to IEC/EN 60721. The integrated DC choke reduces harmonic distortion, with an optional passive filter (VW3A460xx) achieving THDi < 10%.

Parameter Specification
Supply voltage 380...460 V AC, 50/60 Hz, three-phase
Maximum continuous output current 88 A (normal duty)
Maximum transient current (60 s) 97 A (normal duty)
Heavy duty rating 37 kW, 74.5 A continuous, 112 A transient (60 s)
Integrated EMC filter Category C3
Isolation requirement Relay output supply OVC II per IEC/EN 61800-5-1

Key Features for Pump and Fan Control

  • U/f Vc Quadratic (UFQ) control mode optimizes variable-torque fan and pump loads for energy efficiency.
  • Integrated plain text display terminal VW3A1113 with 2-line white backlit LCD and RJ45 interface simplifies commissioning.
  • 6 digital inputs (24 V DC, 2 programmable as pulse inputs) and 3 analog inputs configurable for voltage, current, temperature probe, or water level sensor.
  • 2 RJ45 ports provide Modbus RTU field network and HMI multidrop connectivity.
  • Slot A accepts Extended I/O module VW3A3203, Extended relay module VW3A3204, or PROFIBUS DP V1 module VW3A3607.
  • Fan field-replaceable in under 5 minutes without special tools reduces maintenance downtime.

Figure 2: Technical layout and connection details for the Schneider Electric ATV610D45N4 industrial automation component.

Installation and Environmental Considerations

Mount the drive vertically ±10° for proper cooling. Maintain top/bottom/front clearance of ≥100/100/10 mm (frames 1–5). Power terminal tightening torque is 12 N·m for frame 4. Operating temperature range is -15...+45 °C without derating, extendable to +60 °C with power derating. Altitude up to 1000 m requires no derating; 1000...3000 m requires derating. Relative humidity 5...95% without condensing is acceptable. The IP20 protection rating (IP40 on top) suits enclosed cabinet installations. Maximum motor cable length is 100 m shielded or 200 m unshielded without dv/dt output filter; output filter recommended above 50 m.

Reliability and Maintenance

The ATV610D45N4 is engineered for extended service life in pump and fan applications. Conformal-coated cards resist chemical and mechanical class 3C3 / 3S3 environments. The field-replaceable fan simplifies preventive maintenance. Power dissipation of 1121 W at nominal current must be considered in cabinet thermal design. Regular inspection of cooling airflow and terminal torque is recommended. For applications requiring precise electrical specifications, the drive delivers verified performance across its operating envelope.

Integration with Control Systems

The built-in Modbus RTU port enables direct connection to PLCs and SCADA systems. For PROFIBUS DP networks, the VW3A3607 module provides Profidrive and CiA402 profiles. When integrating into fieldbus architectures, confirm gateway or connection module requirements with the supplier. The drive supports open-loop synchronous motor control (SYNU) for PMSM and reluctance motor control (SRVC), expanding compatibility beyond standard induction motors.

Contact AutoDCSTech with your exact requirements for precise matching.

· Last updated:

Availability & Condition at AutoDCSTech

Part NumberATV610D45N4

Written by , Sales Engineer.

Wayne is a sales engineer with 15 years of experience in the industrial automation industry.

Frequently Asked Questions

Technical Specifications

Product Type I/O Modules
SKU / Part Number ATV610D45N4

Latest News

View All →