Product Introduction
When specifying a variable speed drive for machine automation, engineers require exact electrical characteristics and robust overload capacity. The Schneider Electric ATV320U75N4B from the Altivar Machine ATV320 series delivers 7.5 kW motor power at 380...500 V three-phase supply, with a nominal continuous output current of 17.0 A. Its book format and integrated category C2 EMC filter simplify panel integration while ensuring compliance with IEC/EN 61800-3. This drive is engineered for precise control of asynchronous and synchronous PM motors, making it a reliable choice for demanding industrial applications.

Key Features & Technical Specifications
- Motor power: 7.5 kW (10 HP) at 380...500 V three-phase supply.
- Nominal continuous output current In: 17.0 A maximum at 4 kHz switching frequency.
- Overload capacity: 150% of nominal current for 60 s maximum.
- Integrated EMC filter: category C2, reducing external filtering needs.
- Supply voltage: 380...500 V three-phase (-15%/+10%), 50/60 Hz.
- Maximum input current: 26.5 A at 380 V; 18.7 A at 500 V.
- Output frequency: 0.1 to 599 Hz for wide speed range.
- Protection rating: IP20 for cabinet installation.
- Dimensions (H×W×D): 232 x 150 x 232 mm; weight 7.500 kg.
- Operating temperature: -10 to +50 °C without derating.
The integrated category C2 EMC filter is a distinctive feature: it eliminates the need for external filter components in many installations, saving panel space and reducing wiring complexity while ensuring compliance with EN/IEC 61800-3 category C2. For precise motor control, the drive supports both asynchronous motors (U/F ratio, flux vector control without sensor) and synchronous PM motors (vector control without sensor).
Applications & Use Cases
The ATV320U75N4B is suited for a wide range of industrial machinery. In material handling, it provides precise speed and torque control for conveyors and hoists, leveraging its 150% overload capacity for reliable starts under load. For packaging machines, the drive's high output frequency up to 599 Hz enables high-speed operation, while the integrated EMC filter minimizes electromagnetic interference in sensitive environments. In pumping and fan applications, the energy-saving control modes (quadratic U/F ratio) optimize energy consumption. The drive's robust design and wide operating temperature range make it suitable for demanding environments, from cold storage to process areas.

Installation & Setup
Mount the drive vertically (±10°) with a minimum clearance of 100 mm around the unit to ensure adequate airflow. Terminal tightening torque for Frame 4 is 1.2 to 1.5 N·m, and recommended wire cross-section is 4 to 16 mm². The book format allows side-by-side mounting, reducing panel footprint. For braking applications, an external braking resistor is required; the minimum resistance is 27 Ω. Ensure that the supply voltage matches the drive rating (380...500 V three-phase) and that the motor cable length does not exceed 2 m for category C2 compliance (20 m for category C3 at 4 kHz).
Compatibility & Integration
The drive includes one RJ45 port for CANopen and Modbus Serial line, enabling direct integration into common industrial networks. For other protocols such as EtherNet/IP, PROFINET, or EtherCAT, an optional communication module can be installed in the dedicated slot. When integrating into fieldbus networks, wiring may require an external gateway or connection module; confirm cable and gateway compatibility with the supplier. The drive also features a comprehensive set of I/O: 3 analog inputs, 6 digital inputs, 1 analog output, 2 relay outputs, and a pulse output, providing flexibility for various control schemes. Safety functions include STO up to SIL3/PLe, with additional configurable safety inputs for SS1, SLS, SMS, and GDL.
Maintenance & Reliability
Regular maintenance is minimal due to the drive's solid-state design. Inspect cooling fans and heatsinks every 6 to 12 months, depending on environmental conditions. Ensure that the ambient temperature remains within -10 to +50 °C without derating; above 50 °C, derating is required. The IP20 protection rating requires installation in a cabinet or controlled environment. The drive's engineering-grade precision in manufacturing ensures long service life, and the integrated EMC filter reduces the risk of interference-related faults. For high-altitude installations (above 1000 m), derate the nominal current by 1% per additional 100 m.
Product Support & Availability
At AutoDCSTech, we provide engineering-grade precision in every part we supply. The ATV320U75N4B is in stock and ready to ship, backed by our specialist engineering support to assist with configuration and integration. Contact AutoDCSTech with your exact requirements for precise matching.
Availability & Condition at AutoDCSTech
| Part Number | ATV320U75N4B |
|---|