Technical Specifications Breakdown
Key parameters for the 330102-20-96-10-02-05 are listed below for quick reference:
| Feature | Specification |
|---|---|
| Product Type | 3300 XL 8 mm Proximity Probe |
| Unthreaded Length Option | 20 = 2 in |
| Overall Case Length Option | 96 = 9.6 in |
| Total Length Option | 10 = 1.0 meter (3.3 feet) |
| Connector and Cable-Type Option | 02 = Miniature coaxial ClickLoc connector, standard cable |
| Agency Approval Option | 05 = CSA, ATEX, IECEx Approvals |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 stainless steel (SST) |
| Nominal Probe DC Resistance (1.0 m) | 7.59 ± 0.50 Ω |
| Linear Range | 2 mm (80 mils), from 0.25 to 2.3 mm (10 to 90 mils) |
| Recommended Gap Setting for Radial Vibration | -9 Vdc [approximately 1.27 mm (50 mils)] |
| Probe Temperature Range (Standard) | -52°C to +177°C (-62°F to +350°F) |
| Probe Relative Humidity | < 3% change in ASF at 93% humidity per IEC 68 2 3 |
Industry Applications That Maximize ROI
Turbomachinery Protection
In steam turbines and gas compressors, the 330102-20-96-10-02-05 provides continuous radial vibration and thrust position monitoring. Its 2 mm linear range and -9 Vdc recommended gap setting allow early detection of shaft rub or bearing degradation, preventing catastrophic failures that could cost over $100,000 in repairs.
Pump and Motor Monitoring
For centrifugal pumps and large AC motors, the probe's PPS tip and stainless steel case resist moisture and mild chemicals. The 1.0 meter cable length simplifies installation near the bearing housing, while the miniature coaxial ClickLoc connector ensures a secure, noise-free signal.
Hazardous Area Compliance
With CSA, ATEX, and IECEx approvals, this probe is certified for use in Class I, Zone 0 and Class I, Division 2 environments when paired with appropriate intrinsic safety barriers or non-incendive circuits. This eliminates the need for expensive explosion-proof enclosures, reducing installation costs by up to 30%.

Installation & Setup Guidance
Mount the probe using the 3/8-24 UNF thread with a maximum thread engagement of 0.563 inches. Use field wiring of 0.2 to 1.5 mm² (16 to 24 AWG) with a 3-conductor shielded triad cable. The maximum cable length between the probe and monitor is 305 meters (1,000 feet). For radial vibration, set the initial gap to -9 Vdc (approximately 1.27 mm or 50 mils). Verify the linear range from 0.25 to 2.3 mm (10 to 90 mils) during commissioning.
Maintenance & Reliability
Inspect the probe cable and connector periodically for damage, especially in high-vibration or high-temperature areas. The probe operates reliably from -52°C to +177°C; avoid prolonged exposure below -34°C (-30°F) to prevent pressure seal failure. The probe is not pressure tested before shipment — contact the custom design department if a pressure seal test is needed.
Cost-Effective Vibration Monitoring with the Bently Nevada 330102-20-96-10-02-05
In rotating machinery, unplanned downtime from bearing or shaft failures can cost thousands per hour. The Bently Nevada 330102-20-96-10-02-05 3300 XL 8 mm Proximity Probe delivers precise, reliable displacement measurements that help you detect early signs of wear, imbalance, or misalignment — reducing maintenance costs and extending equipment life.

Compatibility & Integration
The 330102-20-96-10-02-05 is designed for use with Bently Nevada 3300 XL Proximitor Sensors and compatible monitoring systems. The miniature coaxial ClickLoc connector mates directly with standard extension cables. For hazardous locations, follow intrinsic safety wiring per drawing 141092 or non-incendive wiring per drawing 140979.
Selection Guide & Purchasing Advice
When selecting a replacement or new probe, confirm the unthreaded length (2 in), overall case length (9.6 in), and total cable length (1.0 m). The 330102-20-96-10-02-05 is a standard configuration with CSA, ATEX, and IECEx approvals. For extended temperature ranges or different cable lengths, contact AutoDCSTech for alternative options. We stock genuine Bently Nevada parts to ensure long-term reliability.
Troubleshooting & Common Issues
If the output signal is noisy or unstable, check the cable connections and verify that the probe tip is clean and free of debris. Confirm the gap setting is within the linear range (0.25 to 2.3 mm). If the probe fails to respond, measure the DC resistance between center and outer conductors — it should be 7.59 ± 0.50 Ω for a 1.0 meter probe. A significant deviation indicates a damaged cable or internal short.
Availability & Condition at AutoDCSTech
| Part Number | 330102-20-96-10-02-05 |
|---|---|
| Availability | In Stock |
| Condition | New |
| Warranty | One Year |
| Origin | US |