Technical Specifications Breakdown
Key parameters for the 330103-00-03-90-12-05 are listed below for quick reference:
| Feature | Specification |
|---|---|
| Product Type | 3300 XL 8 mm Proximity Probe |
| Thread Size | M10 x 1 |
| Unthreaded Length | 00 mm |
| Overall Case Length | 30 mm |
| Total Length | 9.0 meters (29.5 feet) |
| Connector Type | Miniature coaxial ClickLoc, FluidLoc cable |
| Agency Approvals | CSA, ATEX, IECEx |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 stainless steel |
| Linear Range | 2 mm (80 mils), from 0.25 to 2.3 mm |
| Recommended Gap Setting | -9 Vdc [approx. 1.27 mm (50 mils)] |
| Probe DC Resistance (9.0 m) | 9.87 ± 0.50 Ω |
| Operating Temperature | -52°C to +177°C (-62°F to +350°F) |
| Extended Temperature Range | -52°C to +218°C (tip); -51°C to +260°C (cable) |
Industry Applications
In a steam turbine installation, the 330103-00-03-90-12-05 provides continuous gap voltage feedback, allowing operators to detect early signs of imbalance or misalignment. For centrifugal compressors, its 2 mm linear range and -9 Vdc recommended gap setting ensure stable measurements even under varying load conditions. The CSA, ATEX, and IECEx approvals make it suitable for hazardous areas, such as oil and gas facilities, where intrinsic safety is paramount.

Installation and Setup Guidance
Proper installation begins with verifying the thread engagement: the M10 x 1 thread allows a maximum engagement of 15 mm. Use 3-conductor shielded triad cable with tinned field wiring, sized 0.2 to 1.5 mm² (16 to 24 AWG). The maximum field wiring length between the probe and monitor is 305 meters (1,000 feet). For optimal frequency response, keep wiring as short as practical. Set the initial gap to approximately -9 Vdc (1.27 mm) for radial vibration monitoring. Ensure the probe tip is clean and free of debris before insertion.
Maintenance and Reliability
Inspect the probe and cable periodically for physical damage, especially near the connector and tip. The probe case is made of AISI 303 or 304 stainless steel, offering good corrosion resistance. Avoid exposing the probe to temperatures below -34°C (-30°F) to prevent premature pressure seal failure. The Viton O-ring maintains differential pressure sealing; however, probes are not pressure tested before shipment. If pressure seal integrity is critical, contact the custom design department for testing options.
Industry Evolution and Precision Measurement
For decades, industrial machinery protection has relied on accurate, non-contact vibration and position sensing. The Bently Nevada 3300 XL series represents a milestone in this evolution, offering robust performance in harsh environments. The 330103-00-03-90-12-05 is a 3300 XL 8 mm Proximity Probe designed for critical rotating machinery such as turbines, compressors, and pumps. Its proven eddy current technology delivers reliable shaft displacement data, enabling predictive maintenance and reducing unplanned downtime.

Compatibility and Integration
The 330103-00-03-90-12-05 is designed for use with Bently Nevada 3300 XL Proximitor Sensors and compatible monitoring systems. When installed with intrinsically safe zener barriers per drawing 141092 or galvanic isolators, it achieves Class I, Zone 0: AEx/Ex ia IIC T5...T1 Ga. For non-incendive circuits per drawing 140979, it meets Class I, Zone 2: AEx/Ex nA IIC T5…T1 Gc. Ensure the monitoring system supports the probe's DC resistance of 9.87 ± 0.50 Ω and linear range characteristics.
Selection Guide and Purchasing Advice
When selecting a replacement or new probe, confirm the required total length, thread size, and connector type. The 330103-00-03-90-12-05 features a 9.0 meter FluidLoc cable with a miniature coaxial ClickLoc connector. For applications requiring extended temperature range, verify that the probe tip and cable ratings meet your environment. AutoDCSTech stocks this model and can assist with lifecycle status verification. Contact our team to confirm availability and lead times before ordering.
Troubleshooting and Common Issues
If the probe output voltage drifts outside the expected -1 to -17 Vdc range, first check the gap setting and target surface condition. Verify that the field wiring resistance is within limits and that the cable is not damaged. For intermittent signals, inspect the ClickLoc connector for secure mating. If the probe has been exposed to temperatures below -34°C (-30°F), the pressure seal may be compromised, requiring replacement. Always consult the system manual for detailed troubleshooting procedures.
Availability & Condition at AutoDCSTech
| Part Number | 330103-00-03-90-12-05 |
|---|---|
| Availability | In Stock |
| Condition | New |
| Warranty | One Year |
| Origin | US |