The Lenze E82EV222-2C is a Frequency inverter for industrial control and automation applications.
Lenze E82EV222-2C is a 2.2 kW vector-controlled frequency inverter from the 8200 vector series, rated for 4-pole asynchronous motors in the 230 V mains class. It delivers a nominal output current of 9.5 A at the factory-set 8 kHz switching frequency.
Key Specifications and Performance Data
The inverter provides precise control over a 0...650 Hz output frequency range. Its overload capability reaches 1.8 x rated torque for 60 s, and a maximum output current of 14.2 A is available for 60 s during periodic load change cycles. The table below summarizes the core electrical parameters.
- Rated motor power: 2.2 kW typical (4-pole asynchronous motor)
- Rated output current: 9.5 A nominal at 8 kHz switching frequency
- Max. output current: 14.2 A for 60 s (periodic load change cycle)
- Output frequency: 0...650 Hz
- Switching frequency: 2/4/8/16 kHz selectable (8 kHz factory setting)
- Mains voltage class: 230 V
- Supply voltage: 1/N/PE 180...264 V AC (single-phase, 45...65 Hz); 3/PE 100...264 V AC for 3-phase versions; alternative DC 260...370 V DC supply (except E82EV251/371 units)
- Power consumption: 130 W power loss at Ir / 8 kHz
- Protection rating: IP20
An integrated EMC filter (C0xx base code) and a built-in brake transistor (chopper up to 11 kW) reduce external component count. The unit operates from -10...+55 °C with derating of 2.5%/°C above +40 °C, and stores from -25...+60 °C. Relative humidity tolerance is average 85 % RH without condensation (climatic class 3K3 per EN 50178). Dimensions are 240 × 60 × 140 mm and weight is 1.6 kg.

How Does this drive Handle Communication and Integration?
Built-in ports include an RS232/485 serial system bus for Lenze system bus communication. Fieldbus connectivity is achieved via plug-in communication modules (PROFIBUS DP, CANopen, DeviceNet, INTERBUS, AS-Interface). Two control interface slots are available on this model. When wiring into such networks, an external gateway or connection module may be required; confirm cable and gateway compatibility with AutoDCSTech.
What Are the Failure Modes to Monitor During Maintenance?
Regular inspection should focus on the integrated EMC filter and brake transistor, as these components are subject to thermal stress. The 130 W power loss at rated current and 8 kHz switching frequency indicates heat generation that must be managed within the IP20 enclosure. Operating above +40 °C accelerates aging; derating by 2.5%/°C above +40 °C is mandatory. Verify that humidity remains below the average 85 % RH limit without condensation to prevent insulation degradation. Periodic checks of output current against the 9.5 A nominal rating help detect motor or load issues early.

Applications and Use Cases
This inverter suits single-phase or 3-phase 230 V class installations driving 4-pole asynchronous motors up to 2.2 kW. Typical uses include pumps, fans, and conveyors where variable speed control reduces energy consumption. The 0...650 Hz output frequency range supports high-speed spindle applications, while the 1.8 x rated torque overload for 60 s handles temporary load peaks. Integrated brake transistor simplifies dynamic braking in hoisting or positioning tasks.
Product Support and Availability
AutoDCSTech supplies this drive with engineering-grade precision. Contact AutoDCSTech with your exact requirements for precise matching. Please verify current lifecycle status and availability with AutoDCSTech before ordering.
Availability & Condition at AutoDCSTech
| Part Number | E82EV222-2C |
|---|