The Lenze EVF9331-EV is a Frequency inverter for industrial control and automation applications.
Lenze EVF9331-EV is a three-phase frequency inverter from the 9300 vector series, rated for 55.0 kW motor power and 110.0 A nominal output current at an 8 kHz chopper frequency. Its 150% overload design supports demanding duty cycles, making it a serviceable choice for maintenance teams managing legacy drive assets.
How does this drive handle overload and output current?
The inverter provides 110.0 A nominal output current at 8 kHz chopper frequency and 165.0 A maximum for 60 s. Overload capability reaches 150% rated torque for 60 s, which supports short-term peak loads without tripping. Output power is 76.2 kVA nominal. The chopper frequency is adjustable to 2, 4, 8 or 16 kHz, allowing maintenance engineers to balance acoustic noise against thermal loading.

Key specifications for maintenance planning
- Supply voltage: 3/PE AC 320 to 528 V nominal, 45 to 65 Hz; alternative DC supply 460 to 740 V DC.
- Control modes: V/f characteristic control; vector control (sensorless speed control) selectable.
- Output frequency range: 0 ... 600 Hz max at 16 kHz chopping frequency; 0 ... 300 Hz max at 8 kHz.
- Protection rating: IP20 (NEMA 1).
- Dimensions (H×W×D): 591 × 340 × 285 mm; weight 38.0 kg.
- Operating temperature: 0 to +40 °C rated; +40 to +50 °C with output current derating 2.5% per K.
What communication and feedback interfaces are available?
The unit includes an AIF automation interface (X1) for a pluggable fieldbus module, a system bus CAN (X4), and an incremental encoder input (X8). No fieldbus module is integrated as standard, so protocol selection is a configuration decision. Supported pluggable modules include LECOM-A/B RS232/485, PROFIBUS DP, CANopen, DeviceNet, INTERBUS and LON per official product information. For maintenance engineers, the encoder input enables closed-loop speed feedback when vector control is selected.

Reliability and service considerations
Power loss is 1470 W, which directly affects panel thermal design. The IP20 rating requires installation in an enclosure that limits dust and moisture ingress. Storage temperature ranges from -25 to +55 °C, with transport down to -25 to +70 °C. Relative humidity should average 85 % RH without condensation. Periodic inspection should focus on heatsink airflow, fan operation and terminal torque. Because the 9300 vector series is superseded by newer drive generations, maintenance teams should plan for migration rather than like-for-like replacement. Lenze lists a migration path to the i950 via a PROFIBUS module and the L_ICIP library, though no drop-in same-order-code replacement exists.
Integration and migration note
When connecting to a fieldbus network, an external gateway or connection module may be required depending on the chosen protocol. Confirm cable and gateway compatibility with AutoDCSTech before ordering. For legacy installations, document the existing AIF module configuration to simplify future migration.
Contact AutoDCSTech with your exact requirements for precise matching.
Availability & Condition at AutoDCSTech
| Part Number | EVF9331-EV |
|---|