Lenze E94AMHE0044 is a drive axis module in the Servo Drives 9400 HighLine Multi Drive series, rated 1.5 kW nominal for ASM 4-pole, 400 V class motors. It delivers 5 A nominal output current at 4 kHz switching frequency, with a 7.5 A maximum and 16 A maximum short-term output current.
What maintenance engineers should know about the E94AMHE0044
From a service perspective, the module's DC-bus supply range of DC 260 V -0 % … 775 V +0 % defines the operating window. Rated DC-bus current is 6.7 A nominal, and power loss is 150 W. The overload factor of 4 supports short-term load peaks, which is useful when diagnosing intermittent overcurrent trips.
Built-in ports include CANopen on board (HighLine) and a diagnostic interface (USB via E94AZCUS adapter). Two extension slots accept communication or extension modules (E94AYC...), alongside one memory slot and one safety slot. This architecture allows field diagnostics without removing the module from the cabinet.

How does This unit handle temperature and altitude derating?
Operating temperature is -10 °C … +55 °C (EN 60721-3-3 class 3K3). Above +45 °C, derate rated output current by 2.5 %/°C. For site altitude, derate rated output current by 5 % per 1000 m above 1000 m, up to 4000 m AMSL. Storage temperature is -25 °C … +60 °C (EN 60721-3-1 class 1K3), and transport temperature is -25 °C … +70 °C (EN 60721-3-2 class 2K3).

Key specifications
- Rated motor power: 1.5 kW nominal (ASM 4-pole, 400 V class)
- Rated output current: 5 A nominal at 4 kHz switching frequency
- Max. output current: 7.5 A maximum
- Max. short-term output current: 16 A maximum short-term
- Overload factor: 4
- Rated DC-bus current: 6.7 A nominal
- Power loss: 150 W
- Supply voltage: DC 260 V -0 % … 775 V +0 % (DC-bus operation)
- Protection rating: IP20 (EN 60529); NEMA 250 type 1
- Dimensions (H×W×D): 350 mm (with 507 installation backplane) × 60 mm × 288 mm
- Weight: 4 kg
Reliability and service considerations
Vibration resistance is class 2M2, with operation per EN 60068-2-6: 10 Hz ≤ f ≤ 57 Hz: ±0.075 mm amplitude; 57 Hz < f ≤ 150 Hz: 1.0 g. Germanischer Lloyd adds 5 Hz ≤ f ≤ 13.2 Hz: ±1 mm amplitude; 13.2 Hz < f ≤ 100 Hz: 0.7 g. These figures guide mounting rigidity and periodic inspection of cabinet fixings.
Relative humidity is not published as a numerical value; the climatic class 3K3 per EN 60721-3-3 applies. During maintenance, verify that cabinet ventilation maintains the specified temperature range and that the 150 W power loss is dissipated. Check the diagnostic interface periodically for fault logs.
Contact AutoDCSTech with your exact requirements for precise matching.
Availability & Condition at AutoDCSTech
| Part Number | E94AMHE0044 |
|---|---|
| Availability | In Stock |
| Warranty | One Year |