Lenze E94ASHE0024 is a 9400 HighLine SingleDrive axis module engineered for cabinet mounting, driving a 0.37 kW nominal 4-pole asynchronous motor in the 400 V class. Its rated output current of 1.9 A at 4 kHz switching frequency gives panel builders an exact, verified current envelope for single-axis motion tasks.
A frequent engineering challenge is sizing an axis module for a small asynchronous motor on a 400 V class supply while keeping the drive compact and network-ready. This module resolves that by pairing a 0.37 kW nominal rating with an onboard CANopen port, so the axis integrates without a separate communication card in the first extension slot.
What electrical specifications define the E94ASHE0024?
The supply section accepts 3/PE AC 180 V -0 % … 550 V +0 % at 45 Hz -0 % … 65 Hz +0 % nominal, with an alternative DC feed of DC 260 V -0 % … 775 V +0 %. Rated mains current is 1.5 A nominal with a mains choke and 2.1 A nominal without one, while the rated DC-bus current is 2.6 A nominal.
- Rated motor power: 0.37 kW nominal (ASM 4-pole, 400 V class)
- Rated output current: 1.9 A nominal at 4 kHz switching frequency
- Max. output current: 2.8 A maximum
- Max. short-term output current: 6 A maximum short-term
- Overload factor: 4
- Rated mains current: 1.5 A nominal with mains choke; 2.1 A nominal without mains choke
- Rated DC-bus current: 2.6 A nominal
- Power loss: 110 W
- Supply voltage: 3/PE AC 180 V -0 % … 550 V +0 %, 45 Hz -0 % … 65 Hz +0 % nominal
- Alternative DC supply: DC 260 V -0 % … 775 V +0 %
- Protection rating: IP20 (EN 60529); NEMA 250 type 1

How does integrated CANopen simplify axis integration?
CANopen is available on board in the HighLine variant, and a diagnostic interface is reachable via the E94AZCUS USB adapter. Two extension slots accept communication or extension modules from the E94AYC... family, alongside one memory slot and one safety slot. Because the fieldbus function is already present, the extension slots remain free for other functions.
Integration Note: wiring this module into a CANopen network may require suitable cabling and connection accessories; confirm the exact cable and gateway requirements with AutoDCSTech before commissioning.

Which thermal and mounting limits govern installation?
The module measures 350 mm (with 507 installation backplane) × 60 mm × 288 mm and weighs 4 kg, so cabinet depth and rail layout should be planned around those figures. Operating temperature spans -10 °C … +55 °C under EN 60721-3-3 class 3K3, with rated output current derated by 2.5 %/°C above +45 °C.
Site altitude is rated up to 4000 m AMSL, with rated output current derated by 5 % per 1000 m above 1000 m. Storage temperature covers -25 °C … +60 °C and transport temperature -25 °C … +70 °C. Vibration resistance follows class 2M2, and relative humidity is specified through climatic class 3K3 rather than a numerical %RH value.
Where is this axis module applied?
Typical duty suits single-axis positioning on small asynchronous motors in packaging, material handling and general machine building. In a hypothetical panel retrofit, an engineer replacing a fixed-speed feed on a 400 V class machine could size this module against the 1.9 A nominal output and use the 6 A maximum short-term capability for brief acceleration peaks. The 110 W power loss figure also informs enclosure thermal budgeting.
Contact AutoDCSTech with your exact requirements for precise matching of this drive axis module to your application.
Availability & Condition at AutoDCSTech
| Part Number | E94ASHE0024 |
|---|---|
| Availability | In Stock |
| Warranty | One Year |