When a multi-axis cabinet needs a compact, high-overload axis module that can ride through peak torque demands without oversizing the DC bus, the Lenze E94AMHE0174 provides a precise answer. This Servo Drives 9400 HighLine Multi Drive module is rated for 7.5 kW nominal motor power (ASM 4-pole, 400 V class) and delivers 20.6 A rated output current at 4 kHz switching frequency.
What electrical specifications define this module?
The module operates from a DC-bus supply voltage of DC 260 V -0 % … 775 V +0 %, making it suitable for cabinet architectures that share a common DC bus across axes. Its rated DC-bus current is 25.7 A nominal, while maximum output current reaches 30.9 A and maximum short-term output current reaches 49.5 A. An overload factor of 3 supports demanding acceleration cycles. Power loss is stated at 320 W.
- Rated motor power: 7.5 kW nominal (ASM 4-pole, 400 V class)
- Rated output current: 20.6 A nominal at 4 kHz switching frequency
- Max. output current: 30.9 A maximum
- Max. short-term output current: 49.5 A maximum short-term
- Rated DC-bus current: 25.7 A nominal
- Supply voltage: DC 260 V -0 % … 775 V +0 % (DC-bus operation)
- Overload factor: 3
- Power loss: 320 W
- Protection rating: IP20 (EN 60529); NEMA 250 type 1
- Dimensions (H×W×D): 350 mm (with 507 installation backplane) × 120 mm × 288 mm
- Weight: 8.1 kg

How does CANopen integration simplify cabinet wiring?
CANopen is available on board (HighLine), and a diagnostic interface is accessible via the E94AZCUS USB adapter. Two extension slots accept communication or extension modules (E94AYC...), alongside one memory slot and one safety slot. For network integration, confirm gateway and cabling requirements with AutoDCSTech before commissioning.

Which environmental conditions require derating?
The operating temperature range is -10 °C … +55 °C (EN 60721-3-3 class 3K3). Above +45 °C, derate rated output current by 2.5 %/°C. At site altitudes up to 4000 m AMSL, derate rated output current by 5 % per 1000 m above 1000 m. Storage temperature spans -25 °C … +60 °C (EN 60721-3-1 class 1K3), and transport temperature spans -25 °C … +70 °C (EN 60721-3-2 class 2K3). Vibration resistance follows class 2M2.
How should the module be installed and maintained?
Mount the axis module in a DC-bus cabinet using the 507 installation backplane. Verify that the DC-bus voltage remains within the specified range before energizing. During periodic inspection, check terminal torque and cabinet airflow; the IP20 rating requires a clean, controlled enclosure environment. Because the module is part of the active L-force product range, please verify current lifecycle status and availability with AutoDCSTech before ordering.
Contact AutoDCSTech with your exact requirements for precise matching.
Availability & Condition at AutoDCSTech
| Part Number | E94AMHE0174 |
|---|---|
| Availability | In Stock |
| Warranty | One Year |