The Lenze EVF9338-EV is a Frequency inverter for industrial control and automation applications.
Lenze EVF9338-EV is a three-phase frequency inverter from the 9300 vector series, rated 200 kW for a 4-pole asynchronous motor at 3 AC 400 V. Its 375 A nominal output current at 2 kHz chopper frequency supports continuous heavy-duty operation, while the 150% overload design delivers 560 A maximum for 60 s to ride through high-torque starts.
What drive specifications define this drive?
The inverter accepts a supply of 3/PE AC 340 to 456 V nominal at 45 to 65 Hz, covering the common 400 V industrial grid with margin for voltage sag. Control modes include U/f characteristic control (linear/square), vector control, and sensorless speed control, so the drive can be matched to either simple pump and fan loads or higher-performance machinery. Output frequency reaches 0 ... 600 Hz max at 16 kHz chopping frequency, 0 ... 300 Hz max at 8 kHz, and 0 ... 150 Hz max at 2 kHz and at 4 kHz for sizes 9321-9333, with the chopper frequency adjustable to 1, 2 or 4 kHz.
- Rated motor power: 200 kW (4-pole asynchronous motor, 3 AC 400 V)
- Output current: 375 A nominal at 2 kHz chopper frequency
- Max. output current: 560 A maximum for 60 s
- Overload: 150% rated torque for 60 s
- Supply voltage: 3/PE AC 340 to 456 V nominal, 45 to 65 Hz
- Power loss: 5 kW
- Protection rating: IP20
- Dimensions (H×W×D): 1145 × 500 × 436 mm
- Weight: 200 kg

How does the 150% overload design affect operating cost?
Because the drive holds 150% rated torque for 60 s, it can accelerate high-inertia loads without oversizing the inverter frame. Consequently, the 200 kW rating stays matched to the motor rather than inflated for starting duty, which keeps the 5 kW power loss tied to actual load instead of idle headroom. The 375 A nominal output current at 2 kHz chopper frequency also supports continuous full-load operation, so production throughput is not limited by drive thermal margin.
Which control modes suit vector and sensorless applications?
U/f characteristic control (linear/square) fits centrifugal pumps and fans where quadratic torque reduces energy use at part speed. Vector control and sensorless speed control, by contrast, hold torque accuracy without an encoder, which removes encoder cost and wiring from the installation. The internal fan moves air bottom to top through the 1145 × 500 × 436 mm housing, so cabinet ventilation should follow that vertical path to protect the 5 kW heat dissipation budget.

How is fieldbus integration handled on this model?
The AIF automation interface (X1) accepts a pluggable fieldbus module; none is integrated as standard. Supported modules include LECOM-A/B, PROFIBUS DP, CANopen, DeviceNet, INTERBUS and LON per official product information. A system bus CAN (X4) port is built in for drive-to-drive coordination. When wiring into such networks, an external gateway or connection module may be required, so confirm cable and gateway selection with AutoDCSTech before commissioning.
What environmental limits apply in service?
Operating temperature is 0 to +50 °C and storage temperature is -20 to +60 °C. Humidity class F applies, non-condensing, with no specific %RH published in official 9300 vector product information. The IP20 rating means the enclosure protects against finger contact, not dust or water, so the drive belongs in a filtered cabinet. Periodic inspection should focus on fan airflow and heatsink contamination, since restricted cooling raises junction temperature and shortens capacitor life.
Please verify current lifecycle status and availability with AutoDCSTech before ordering. Contact AutoDCSTech with your exact requirements for precise matching.
Availability & Condition at AutoDCSTech
| Part Number | EVF9338-EV |
|---|