The Woodward 5464-843 is a Block diagram for industrial control and automation applications.
Woodward 5464-843 is a NetCon 5000 CPU module engineered for MicroNet digital control systems. It coordinates smart I/O modules through an initialization and key-broadcast scheme, enabling each module to manage its own rate-group scheduling with minimal CPU intervention.
What distinguishes this unit in a MicroNet architecture?
The module acts as the central processor for MicroNet systems, communicating with smart I/O cards that carry their own microcontrollers. During initialization, the CPU tells each module which rate group each channel runs in and passes special configuration data, such as thermocouple type. At run time, the CPU periodically broadcasts a key to all I/O cards, indicating which rate groups update. This distributed approach reduces CPU overhead while maintaining deterministic control.
Smart I/O modules perform on-card online fault detection and automatic calibration. Each input channel has its own precision voltage reference, read once per minute by the module microcontroller for fault detection and temperature compensation. If a reading falls outside expected limits, the channel is flagged and the CPU executes the application engineer's programmed response.

Key technical parameters
- Manufacturer: Woodward
- Model: this unit
- Product type: NetCon 5000 CPU module
- Catalog: MicroNet Digital Control
- Origin: United States (US)
- HS code: 85389091
- Dimensions: 16 cm × 16 cm × 12 cm
- Weight: 0.8 kg
These verified specifications support engineering-grade integration planning. For parameters not listed here, refer to the official Woodward datasheet.

How does the CPU module handle smart I/O and fault response?
The CPU initializes each smart module, turning off the module LED after power-on self-tests pass and the CPU has initialized the module. The LED illuminates to indicate an I/O fault. Output modules monitor voltage or current per channel and alert the system on fault detection. Each I/O module includes a visible fuse accessible through a cutout in the plastic cover; if blown, replace it with a fuse of the same type and size.
For actuator driver modules in the same family, the CPU sends digital information and the module generates proportional driver signals with maximum ranges of 0 to 25 mAdc or 0 to 200 mAdc. A MicroNet low-density discrete (gray) cable must be used with such modules; analog (black) cables are not compatible.
Integration and maintenance considerations
Install this unit in a MicroNet rack according to Woodward documentation. Verify that all I/O modules are seated and that gray discrete cables are used where required. During commissioning, confirm that the CPU successfully initializes each smart module and that no fault LEDs remain illuminated.
Periodic inspection should include checking the visible fuses on I/O modules and confirming that fault LEDs are off during normal operation. Because smart modules perform automatic calibration using their precision voltage references, routine manual calibration is not required. However, any channel flagged with a fault should be investigated per the application program's fault-handling logic.
Contact AutoDCSTech with your exact requirements for precise matching.