The Woodward 8440-1945 is a As follows for industrial control and automation applications.
Woodward 8440-1945 is a sheet-metal-framed genset controller from the easYgen-3400 series, carrying an alternate designation of easYgen-3400-1-P1. Its primary setting range spans 50 - 650,000 Vac with an accuracy class of 0.5, so engineers can apply it across a wide band of generator voltages without changing platform.
What this unit Controller Delivers
The unit is built for remote operation: because the sheet-metal frame variant carries no LCD screen, all supervision and adjustment happen through connected systems. The P1 configuration also carries fewer connection interfaces on the frame, which suits installations where a defined I/O set is sufficient. Analog I/O and discrete expansion board connectivity are both present, letting a panel builder extend signal handling as the plant grows.
Eleven basic application modes cover the common switching topologies, including GCB/L-GGB, GCB/L-GGB/L-MCB, GCB/GGB/L-MCB, GCBopen, GCB/MCB, GCB, none, GCB/LS5, GCB/GGB, GCB/L-MCB and GCB/GGB/MCB. Each mode carries distinct functionality; the GCB/GGB/L-MCB mode, for instance, starts and stops the engine, protects the engine and generator, and operates with auto mains failure (AMF). Master/slave control supports both mains parallel and islanded operation.

Key Specifications at a Glance
- Accuracy Class: 0.5
- Primary Setting Range: 50 - 650,000 Vac
- Setting Range: 1 - 32,000 A
- Front Panel Dimensions: 282W X 216H X 96D mm
- Storage Temp.: -22 - 176 F
- Weight: Approx. 1,850 g (4 lbs)
For a protection engineer, the 0.5 accuracy class is the decisive number: measurement error stays tight enough that pickup thresholds can be set with confidence rather than padded margins. The current setting range of 1 - 32,000 A likewise covers small standby sets through large parallel installations.
Which Applications Suit This Controller?
Because the platform supports mains parallel and islanded operation, it fits plants that need both grid-tied and standalone running. Typical deployments include standby generator rooms with AMF logic, multi-generator plants using master/slave load sharing, and cabinet-mounted panels where the controller sits behind a door rather than on it. The sheet-metal housing and 282W X 216H X 96D mm front panel footprint make cabinet layout predictable during design.

Installation and Configuration Notes
Plan the panel cutout around the stated front panel dimensions, then confirm depth clearance for wiring behind the frame. Since this variant has no local display, commission it through the connected supervisory system and verify each application mode against the intended switching scheme before energizing. Keep storage conditions within -22 - 176 F prior to installation. Expansion boards should be mated before final wiring so analog and discrete channels are accounted for in the drawing set.
Reliability and Long-Term Ownership
With no screen on the front, the frame removes a common wear point from the panel face. Periodic inspection should focus on terminal torque, cabinet ventilation and the condition of expansion board connections. Stable storage temperature control before commissioning protects the electronics from condensation damage.
Contact AutoDCSTech with your exact requirements for precise matching.
Availability & Condition at AutoDCSTech
| Part Number | 8440-1945 |
|---|