When Cabinet Space and Heat Define the Design
An OEM building a high-density drive cabinet faced a familiar constraint: standard heatsink inverters consumed depth and recirculated heat into the enclosure. The solution was a cold-plate variant of the Lenze 8200 vector series, model E82CV223K4B201. By replacing the heatsink with a bare metal cooling plate connected to a customer-side cooler, this 22.0 kW inverter moves thermal management outside the electrical cabinet. The result is a drive that integrates into space-constrained systems without compromising power density or control performance.

Precise Electrical Specifications
The E82CV223K4B201 is rated for 22.0 kW typical motor power with a 4-pole three-phase asynchronous motor. Its rated output current is 47 A nominal at an 8 kHz switching frequency, with a maximum output current of 70.5 A for 60 s. This periodic overload cycle—1 min at Imax followed by 2 min base load at 75% Ir—supports applications with short-duration peak torque demands. The supply voltage range is 3/PE AC 320 V -0% … 550 V +0% at 45 … 65 Hz, accommodating diverse industrial power networks. Control modes include V/f characteristic (linear or quadratic) and sensorless vector control, with an output frequency range of -650 … +650 Hz. An integrated brake transistor simplifies dynamic braking without external components.
Cold-Plate Thermal Engineering
The defining feature of the E82CV223K4B201 is its thermal path. Dissipated power loss is 610 W, and the thermal resistance between the cooling plate and the cooling medium is Rth ≤ 0.057 K/W. The maximum permissible cooling-plate temperature is 75 °C. These figures allow system designers to specify a cooler that maintains the plate within limits under worst-case ambient conditions. Operating temperature is -10 … +50 °C, derated by 2.5%/°C above +40 °C. Storage temperature is -25 … +60 °C, and relative humidity is average 85 % RH without condensation (climatic class 3K3 per EN 50178). Protection rating is IP20.

I/O and Communication
Built-in I/O includes one analog input, one analog output, four digital inputs, one digital output, and one relay output (changeover contact, 250 V AC / 3 A). The X3 control terminal strip provides access to analog and digital signals. No fieldbus protocols are built in; communication expansion requires a plug-in function module from the E82ZAF* family, installed in the FIF slot. This modular approach allows the drive to adapt to various network standards as system requirements evolve.
Integration and Mounting
Mounting the E82CV223K4B201 requires a customer-supplied cooler with sufficient thermal capacity to maintain the cooling plate at or below 75 °C. The cooling plate is a bare metal surface, so thermal interface material and flatness of the mating surface are critical to achieving the specified Rth. Electrical installation follows standard practices for 3/PE AC systems, with attention to the 320 … 550 V input range. The X3 terminal strip accepts control wiring for the analog and digital I/O. For fieldbus integration, the appropriate E82ZAF* module must be ordered separately and installed in the FIF slot.
Reliability and Maintenance
Because the inverter has no integral heatsink, dust and contaminants are less likely to accumulate on cooling surfaces. However, the external cooler must be inspected at regular intervals to ensure unobstructed airflow or coolant flow. The cooling plate itself should be checked for corrosion or scaling, particularly in liquid-cooled systems. Operating the drive within the specified temperature range and derating above +40 °C will maximize service life. The IP20 protection rating means the unit should be installed in a controlled environment, typically within an enclosure that meets the overall system's ingress protection requirements.
Lifecycle and Migration
The 8200 vector series is listed on Lenze's official "previous products" page, and the cold-plate special design is available on request. For new designs, Lenze confirms a migration path to the i950 series, which emulates 8200 vector behaviour via the i950 PROFIBUS module and L_ICIP library. There is no drop-in same-order-code replacement, so system integrators should plan for parameter transfer and wiring adaptation when upgrading.
Support and Availability
AutoDCSTech supplies the E82CV223K4B201 with engineering-grade precision, backed by specialist engineering support for configuration and integration questions. In stock and ready to ship, this inverter is available for immediate deployment. Contact AutoDCSTech with your exact requirements for precise matching.
Availability & Condition at AutoDCSTech
| Part Number | E82CV223K4B201 |
|---|