I/O Modules PLC & I/O Modules

E82CV222K4C Lenze 2.2 kW Cold-Plate Inverter

On Request
Brand: Lenze
Product No. E82CV222K4C

Lenze E82CV222K4C is a 2.2 kW 8200 vector inverter with cold-plate cooling, 5.6 A rated output, and 320–550 V supply for cabinet integration.

Contact Us
Fast Worldwide Shipping
100% Genuine Products
Warranty Included

Product Description

Lenze E82CV222K4C is a frequency inverter from the 8200 vector series that uses cold-plate technology. Its heatsink is replaced by a bare metal cooling plate for connection to a separate customer-side cooler. The unit delivers 2.2 kW typical motor power and 5.6 A rated output current at 8 kHz switching frequency.

How does the cold-plate design affect maintenance?

From a maintenance engineer's perspective, the cold-plate design moves heat rejection to an external cooling circuit. The dissipated power loss is 100 W, and thermal resistance between cooler and cooling medium is Rth ≤ 0.3 K/W. The maximum permissible cooling-plate temperature is 75 °C. Therefore, routine checks should focus on the cooling medium flow and plate temperature rather than fan or heatsink fouling. The IP20 protection rating means the unit must be installed in a controlled cabinet environment.

Figure 1: Front view of the Lenze E82CV222K4C Replaced by a bare metal cooling plate connected to a separate customer-side showing its physical design and enclosure.

Key electrical and control specifications

The supply voltage range is 3/PE AC 320 V -0% … 550 V +0% at 45 … 65 Hz. Output frequency spans -650 … +650 Hz. Control supports V/f characteristic (linear/quadratic) and sensorless vector control. An integrated brake transistor is included. Built-in I/O comprises 1 analog input, 1 analog output, 4 digital inputs, 1 digital output, and 1 relay output (changeover contact, 250 V AC / 3 A).

  • Rated motor power: 2.2 kW typical (4-pole three-phase asynchronous motor)
  • Rated output current: 5.6 A nominal at 8 kHz switching frequency
  • Max. output current: 8.4 A for 60 s (periodic load cycle: 1 min overload at Imax / 2 min base load at 75% Ir)
  • Supply voltage: 3/PE AC 320 V -0% … 550 V +0%; 45 … 65 Hz
  • Operating temperature: -10 … +55 °C (derated by 2.5%/°C above +40 °C)
  • Storage temperature: -25 … +60 °C
  • Relative humidity: average 85 % RH, without condensation (climatic class 3K3 per EN 50178)
  • Protection rating: IP20

What communication options are available?

No fieldbus protocols are built in. The X3 control terminal strip provides analog and digital I/O. For network integration, a FIF slot accepts plug-in function modules from the E82ZAF* family. Consequently, system designers must specify the appropriate module separately. Integration note: wiring into a fieldbus network may require an external gateway or connection module; confirm cable and gateway compatibility with AutoDCSTech.

Figure 2: Technical layout and connection details for the Lenze E82CV222K4C Replaced by a bare metal cooling plate connected to a separate customer-side.

Typical applications and service considerations

Cold-plate inverters suit installations where heat is removed by a shared liquid cooling circuit. Typical uses include machine tools, plastics machinery, and printing equipment. Because the cooling plate interfaces with a customer-side cooler, maintenance schedules should include checking the thermal contact and coolant condition. The wide supply voltage tolerance supports global plant voltages. For legacy support, Lenze confirms a migration path to the i950 series, which emulates 8200 vector behaviour via an i950 PROFIBUS module and L_ICIP library; no drop-in same-order-code replacement exists. Please verify current lifecycle status and availability with AutoDCSTech before ordering.

· Last updated:

Availability & Condition at AutoDCSTech

Part NumberE82CV222K4C

Written by , Sales Engineer.

Wayne is a sales engineer with 15 years of experience in the industrial automation industry.

Frequently Asked Questions

Technical Specifications

Product Type I/O Modules
SKU / Part Number E82CV222K4C

Latest News

View All →