Lenze E82CV222K4C is a frequency inverter from the 8200 vector series that uses cold-plate technology. Its heatsink is replaced by a bare metal cooling plate for connection to a separate customer-side cooler. The unit delivers 2.2 kW typical motor power and 5.6 A rated output current at 8 kHz switching frequency.
How does the cold-plate design affect maintenance?
From a maintenance engineer's perspective, the cold-plate design moves heat rejection to an external cooling circuit. The dissipated power loss is 100 W, and thermal resistance between cooler and cooling medium is Rth ≤ 0.3 K/W. The maximum permissible cooling-plate temperature is 75 °C. Therefore, routine checks should focus on the cooling medium flow and plate temperature rather than fan or heatsink fouling. The IP20 protection rating means the unit must be installed in a controlled cabinet environment.

Key electrical and control specifications
The supply voltage range is 3/PE AC 320 V -0% … 550 V +0% at 45 … 65 Hz. Output frequency spans -650 … +650 Hz. Control supports V/f characteristic (linear/quadratic) and sensorless vector control. An integrated brake transistor is included. Built-in I/O comprises 1 analog input, 1 analog output, 4 digital inputs, 1 digital output, and 1 relay output (changeover contact, 250 V AC / 3 A).
- Rated motor power: 2.2 kW typical (4-pole three-phase asynchronous motor)
- Rated output current: 5.6 A nominal at 8 kHz switching frequency
- Max. output current: 8.4 A for 60 s (periodic load cycle: 1 min overload at Imax / 2 min base load at 75% Ir)
- Supply voltage: 3/PE AC 320 V -0% … 550 V +0%; 45 … 65 Hz
- Operating temperature: -10 … +55 °C (derated by 2.5%/°C above +40 °C)
- Storage temperature: -25 … +60 °C
- Relative humidity: average 85 % RH, without condensation (climatic class 3K3 per EN 50178)
- Protection rating: IP20
What communication options are available?
No fieldbus protocols are built in. The X3 control terminal strip provides analog and digital I/O. For network integration, a FIF slot accepts plug-in function modules from the E82ZAF* family. Consequently, system designers must specify the appropriate module separately. Integration note: wiring into a fieldbus network may require an external gateway or connection module; confirm cable and gateway compatibility with AutoDCSTech.

Typical applications and service considerations
Cold-plate inverters suit installations where heat is removed by a shared liquid cooling circuit. Typical uses include machine tools, plastics machinery, and printing equipment. Because the cooling plate interfaces with a customer-side cooler, maintenance schedules should include checking the thermal contact and coolant condition. The wide supply voltage tolerance supports global plant voltages. For legacy support, Lenze confirms a migration path to the i950 series, which emulates 8200 vector behaviour via an i950 PROFIBUS module and L_ICIP library; no drop-in same-order-code replacement exists. Please verify current lifecycle status and availability with AutoDCSTech before ordering.
Availability & Condition at AutoDCSTech
| Part Number | E82CV222K4C |
|---|