I/O Modules I/O Modules

E82ZAFAC010 2 Analog Inputs 10-bit I/O Module

On Request
Brand: Lenze
Product No. E82ZAFAC010

Lenze E82ZAFAC010 adds 2 analog inputs, 2 analog outputs and 7 digital inputs to the 8200 vector drive through a pluggable spring-clamp terminal strip.

Contact Us
Fast Worldwide Shipping
100% Genuine Products
Warranty Included

Product Description

Lenze E82ZAFAC010 is an application I/O PT function module for the 8200 vector and 8200 motec drive families, seated in the FIF slot and powered from the host drive internal bus. It provides 2 analog inputs (0 … ±10 V, 0/4 … 20 mA, 10-bit), 2 analog outputs (0 … 10 V, max. 2 mA), 7 digital inputs at PLC level, 2 digital outputs, 1 frequency output (0.05 … 10 kHz, max. 8 mA HTL) and 1 relay output.

A machine builder integrating a 8200 vector drive into a line with analog setpoint trimming and a fast encoder-style feedback signal faces a familiar constraint: the drive needs more I/O than the base unit offers, yet the cabinet has no room for separate remote I/O hardware. This unit answers that constraint directly. Because the module plugs into the FIF slot and draws from the drive internal bus, no external supply rail is required and no additional enclosure volume is consumed.

What electrical parameters define this unit module?

The analog front end is the decisive element for control accuracy. Both analog inputs accept 0 … ±10 V or 0/4 … 20 mA at 10-bit resolution, so a single module covers voltage and current transmitters without external signal conditioning. The analog outputs deliver 0 … 10 V at a maximum of 2 mA, suitable for driving high-impedance monitoring inputs. Digital inputs operate at PLC level, and two of them can be configured as frequency inputs up to 102.4 kHz, which allows a speed feedback signal to reach the drive without a dedicated tachometer card.

Isolation is specified as 50 V AC to reference earth/PE. That figure defines the permissible potential difference between the module reference and protective earth, so panel builders should verify equipotential bonding across the analog loop before commissioning. The pluggable spring-clamp terminal strip accepts rigid or flexible conductors of 1.5 mm² (AWG 16) without ferrules, which speeds field wiring and allows the strip to be removed for pre-assembly.

  • Analog inputs: 2 channels, 0 … ±10 V, 0/4 … 20 mA, 10-bit
  • Analog outputs: 2 channels, 0 … 10 V, max. 2 mA
  • Digital inputs: 7 at PLC level, 2 optional frequency inputs up to 102.4 kHz
  • Digital outputs: 2, plus 1 relay output
  • Frequency output: 0.05 … 10 kHz, max. 8 mA HTL
  • Electrical connection: pluggable spring-clamp strip, 1.5 mm² (AWG 16) without ferrules
  • Insulation voltage to reference earth/PE: 50 V AC
  • Supply voltage: not applicable, powered by host drive internal bus
  • Operating temperature: -20 … +60 °C
  • Storage temperature: -25 … +60 °C
  • Relative humidity: average 85 % RH, without condensation (climatic class 3K3 per EN 50178)

Figure 1: Front view of the Lenze E82ZAFAC010 Analog inputs showing its physical design and enclosure.

How does the module integrate with the 8200 vector drive?

Installation is mechanical and electrical at once. The module seats in the FIF slot of the 8200 vector or 8200 motec, and the plug-in terminal strip X3 carries all field signals. Since the module is powered through the host drive internal bus, there is no separate supply terminal to wire. Fieldbus communication is not part of this module: the source data states protocols as none, with fieldbus handled by a separate bus function module. Engineers planning a networked axis should therefore budget for that companion module rather than expect network access from this unit itself.

For analog wiring, route signal cables away from motor leads and observe the 50 V AC insulation limit to reference earth. Because the terminal strip is pluggable, harnesses can be built and continuity-checked on the bench before the strip is seated.

Figure 2: Technical layout and connection details for the Lenze E82ZAFAC010 Analog inputs.

Where is this I/O module typically applied?

Typical use follows the channel mix. Analog inputs read pressure or flow transmitters on pump and fan drives; analog outputs feed trend recorders or upstream controllers; the frequency inputs capture speed feedback; and the relay output handles a status or enable interlock. In each case the module keeps signal conditioning inside the drive, which shortens the analog path and reduces terminal count in the cabinet.

What should maintenance and lifecycle planning cover?

Periodic inspection should confirm terminal strip seating, conductor retention and freedom from condensation, since the climatic rating assumes 85 % RH without condensation. The source data records this model on the official Lenze previous products page, superseded by newer drive generations. Please verify current lifecycle status and availability with AutoDCSTech before ordering.

Contact AutoDCSTech with your exact requirements for precise matching.

· Last updated:

Availability & Condition at AutoDCSTech

Part NumberE82ZAFAC010

Written by , Sales Engineer.

Wayne is a sales engineer with 15 years of experience in the industrial automation industry.

Frequently Asked Questions

Technical Specifications

Product Type I/O Modules
SKU / Part Number E82ZAFAC010