I/O Modules PLC & I/O Modules

E82CV551K4C | Lenze 0.55 kW Cold-Plate Inverter

On Request
Brand: Lenze
Product No. E82CV551K4C

Lenze E82CV551K4C: 8200 vector cold-plate frequency inverter, 0.55 kW, 1.8 A, 3/PE AC 320–550 V, IP20, no built-in fieldbus.

Contact Us
Fast Worldwide Shipping
100% Genuine Products
Warranty Included

Product Description

Lenze E82CV551K4C is a frequency inverter from the 8200 vector series in cold-plate technology. Instead of a standard heatsink, a bare metal cooling plate connects to a customer-side cooler. Its rated motor power is 0.55 kW typical for a 4-pole three-phase asynchronous motor.

How does the cold-plate design solve thermal pain points?

Conventional inverters dissipate heat into the cabinet air. This unit instead transfers 30 W of power loss through a cooling plate with thermal resistance Rth ≤ 1.0 K/W between cooler and cooling medium. The maximum permissible cooling-plate temperature is 75 °C. This arrangement suits installations where the cooling medium is managed separately from the electrical enclosure.

Figure 1: Front view of the Lenze E82CV551K4C Replaced by a bare metal cooling plate connected to a separate customer-side showing its physical design and enclosure.

Which electrical specifications matter for integration?

The supply voltage is 3/PE AC 320 V -0% … 550 V +0% at 45 … 65 Hz. Rated output current is 1.8 A nominal at 8 kHz switching frequency. For periodic overload, maximum output current is 2.7 A for 60 s, following a cycle of 1 min at Imax and 2 min base load at 75% Ir. An integrated brake transistor is included. The X3 control terminal strip provides analog and digital I/O. No fieldbus protocol is built in; the FIF slot accepts plug-in function modules from the E82ZAF* family.

What are the environmental and protection limits?

Operating temperature is -10 … +55 °C, derated by 2.5%/°C above +40 °C. Storage temperature is -25 … +60 °C. Relative humidity averages 85 % RH without condensation, climatic class 3K3 per EN 50178. Protection rating is IP20.

Figure 2: Technical layout and connection details for the Lenze E82CV551K4C Replaced by a bare metal cooling plate connected to a separate customer-side.

How does the inverter address control and load challenges?

V/f characteristic control (linear or quadratic) and sensorless vector control cover an output frequency range of -650 … +650 Hz. This flexibility supports both simple and dynamic loads. The cold-plate variant is a special design available on request. Lenze confirms a migration path to the i950, which emulates 8200 vector behaviour via an i950 PROFIBUS module and the L_ICIP library. No drop-in same-order-code replacement exists.

What should engineers verify before ordering?

Dimensions and weight are not published as numerical values for this cold-plate variant. Refer to the official mounting instructions for dimension drawings. Please verify current lifecycle status and availability with AutoDCSTech before ordering. Contact AutoDCSTech with your exact requirements for precise matching.

· Last updated: