I/O Modules PLC & I/O Modules

E82EV152-4C200 1.5 kW 400 V Vector Inverter

On Request
Brand: Lenze
Product No. E82EV152-4C200

Lenze E82EV152-4C200 8200 vector inverter: 1.5 kW rated power, 3.9 A output at 8 kHz, 320...550 V AC three-phase input, 0...650 Hz output frequency.

Contact Us
Fast Worldwide Shipping
100% Genuine Products
Warranty Included

Product Description

Cost-Driven Selection: Why the E82EV152-4C200 Still Earns Its Panel Space

Every legacy drive decision is a cost decision. The Lenze E82EV152-4C200, a built-in vector-controlled frequency inverter from the 8200 vector series, is rated for a 1.5 kW typical 4-pole asynchronous motor on a 400 V mains class. For plants running existing 8200 vector installations, the exact part number matters: the C2xx variant is supplied without an integrated EMC filter, which changes both cabinet wiring cost and filter procurement. This is engineering-grade precision applied to the total cost of ownership, not a generic drive listing.

Figure 1: Front view of the Lenze E82EV152-4C200 industrial automation component showing its physical design and enclosure.

Technical Specifications and Their Cost Implications

Parameter Verified Value Cost / Efficiency Implication
Supply voltage 3/PE 320...550 V AC (45...65 Hz); alternative DC 450...775 V DC supply Wide AC window tolerates grid sag without nuisance trips; DC feed option supports shared DC-bus architectures
Rated output current 3.9 A nominal at 8 kHz switching frequency Exact current headroom sizing avoids overspecifying the next frame size
Max. output current 5.9 A for 60 s (periodic load change cycle) Short-term reserve covers starting peaks without a larger drive purchase
Rated motor power 1.5 kW typical (4-pole asynchronous motor) Direct match to standard motor rating; no derating margin to pay for
Output frequency 0...650 Hz Headroom for high-speed spindles and future process changes
Switching frequency 2/4/8/16 kHz selectable (8 kHz factory setting) Lower switching frequency reduces inverter losses; higher settings trade loss for motor noise
Power consumption 100 W power loss at Ir / 8 kHz Quantifiable cabinet heat load for cooling and energy budgeting
Overload 1.8 x rated torque for 60 s Handles breakaway torque of conveyors and mixers without upsizing
Integrated brake transistor Yes (built-in chopper up to 11 kW) Eliminates external chopper cost and panel space on braking duty
Protection rating IP20 Cabinet-mount only; enclosure cost planned accordingly

Isolation, Input Voltage and Output Current in Practice

The input voltage window of 320...550 V AC is unusually wide for a 400 V class unit, and that width is a cost buffer: installations on weak grids or long motor cables see fewer undervoltage faults, and each avoided trip is avoided downtime. Output current is the sizing anchor. At 3.9 A nominal with an 8 kHz switching frequency, the E82EV152-4C200 pairs precisely with a 1.5 kW 4-pole motor; the 5.9 A 60-second capability and 1.8 x rated torque overload give a verified reserve for periodic load change cycles. On isolation, the unit is a built-in inverter designed for panel integration, and the C2xx variant carries no integrated EMC filter, so the installer must plan external filtering and verify the isolation and earthing arrangement of the machine. That is a deliberate cost trade: filter cost moves to the cabinet bill of materials, but the drive remains compatible with installations where a shared external filter already exists.

Figure 2: Technical layout and connection details for the Lenze E82EV152-4C200 industrial automation component.

Failure Mode Analysis: Where These Drives Actually Cost Money

Three failure paths dominate in service. First, thermal stress: operation above +40 °C requires derating of 2.5 %/°C up to +55 °C, and a drive run at full current in a hot cabinet will trip on overtemperature long before it fails outright. The 100 W power loss figure at rated current and 8 kHz is the number to use for enclosure cooling calculations. Second, DC-bus overvoltage during braking: the integrated brake transistor is present, but only saves cost if a braking resistor is actually wired to it. Third, contamination: IP20 protection admits conductive dust, and the 85 % RH average humidity limit without condensation (climatic class 3K3 per EN 50178) means condensation events, not humidity itself, are the enemy. Each of these is a maintenance cost that a scheduled inspection prevents.

Integration and Communication

Built-in ports are RS232/485 serial system bus, supporting the Lenze system bus. Fieldbus connectivity is achieved through plug-in communication modules, with PROFIBUS DP, CANopen, DeviceNet, INTERBUS and AS-Interface available; the unit provides 2 control interfaces via plug-in function/communication module slots. Integration Note: wiring into such networks may require an external gateway or connection module; confirm cables and gateways with the supplier before commissioning. Reusing existing plug-in modules from a failed unit is the lowest-cost migration path and should be verified part by part.

Replacement Path and Lifecycle Cost

Lenze lists the 8200 vector among its previous products, superseded by newer drive generations. There is no drop-in same-order-code replacement, but Lenze confirms a migration path to the i950, which emulates 8200 vector behaviour via the i950 PROFIBUS module and L_ICIP library. For a cost analysis, the decision is straightforward: keep spares of the exact E82EV152-4C200 to protect existing machines, or budget a full i950 migration including re-engineering and re-commissioning. Mixing the two strategies per machine is often the most economical route.

Support and Availability

AutoDCSTech supplies the E82EV152-4C200 with verified specifications and specialist engineering support for matching against your motor nameplate and panel conditions. Contact AutoDCSTech with your exact requirements for precise matching.

· Last updated:

Availability & Condition at AutoDCSTech

Part NumberE82EV152-4C200

Written by , Sales Engineer.

Wayne is a sales engineer with 15 years of experience in the industrial automation industry.

Frequently Asked Questions

Technical Specifications

Product Type I/O Modules
SKU / Part Number E82EV152-4C200

Latest News

View All →