Product Introduction
When specifying a frequency inverter for a 2.2 kW asynchronous motor, the critical parameters are input voltage tolerance, output current headroom, and isolation integrity. The Lenze E82EV222K4C200 from the 8200 vector series addresses these exact requirements with a 400 V class design, a rated output current of 5.6 A at 8 kHz switching frequency, and a supply voltage range of 3/PE 320...550 V AC. This built-in vector-controlled inverter is engineered for applications where precise speed and torque regulation are non-negotiable. The C2xx variant omits an integrated EMC filter, allowing system integrators to implement site-specific filtering. With its RS232/485 serial system bus and plug-in communication module slots, this drive integrates into existing control architectures without compromise.

Key Features & Technical Specifications
- Rated motor power: 2.2 kW typical for 4-pole asynchronous motors.
- Rated output current: 5.6 A nominal at 8 kHz switching frequency.
- Max. output current: 8.4 A for 60 s, supporting periodic load changes.
- Supply voltage: 3/PE 320...550 V AC (45...65 Hz); alternative DC 450...775 V DC supply.
- Output frequency: 0...650 Hz for high-speed applications.
- Switching frequency: 2/4/8/16 kHz selectable (8 kHz factory setting).
- Integrated brake transistor: built-in chopper up to 11 kW.
- Overload capability: 1.8 x rated torque for 60 s.
- Operating temperature: -10...+55 °C, derated by 2.5%/°C above +40 °C.
- Protection rating: IP20; relative humidity average 85 % RH, without condensation (climatic class 3K3 per EN 50178).
The absence of an integrated EMC filter (C2xx variant) is a deliberate design choice for panel builders who require external filter selection to meet specific installation EMC profiles. The built-in brake transistor simplifies dynamic braking without external chopper hardware.
Failure Mode Analysis: Input Voltage and Isolation
In industrial environments, voltage sags and isolation breakdowns are leading causes of drive failure. The E82EV222K4C200 mitigates these risks through a wide input voltage window of 320...550 V AC, accommodating both nominal 400 V systems and significant fluctuations. The alternative DC 450...775 V DC supply enables direct integration with DC bus systems, reducing conversion losses. Isolation between power and control circuits is fundamental to the design, preventing ground loops and protecting sensitive RS232/485 communication. For engineers specifying drives for harsh electrical environments, these parameters translate directly into reduced downtime and extended service life. The IP20 protection rating requires installation in a controlled enclosure, where environmental factors such as humidity (average 85 % RH, without condensation) and temperature (derated above +40 °C) must be managed to avoid condensation-induced failures.

Compatibility & Integration
The 8200 vector series provides two plug-in function/communication module slots (three for units above 15 kW), enabling fieldbus connectivity via PROFIBUS DP, CANopen, DeviceNet, INTERBUS, and AS-Interface modules. The built-in RS232/485 serial system bus supports Lenze system bus protocol for multi-drive coordination. When integrating into fieldbus networks, note that external gateways or connection modules may be required; confirm cable and gateway compatibility with the supplier. The drive's parameterization can be managed through Lenze engineering tools, ensuring exact replication of control sequences across multiple units.
Maintenance & Reliability
Preventive maintenance for the E82EV222K4C200 focuses on thermal management and electrical connections. Inspect cooling paths and fan operation at intervals aligned with the operating temperature profile; derating above +40 °C by 2.5%/°C must be respected to avoid over-temperature trips. Verify torque on power terminals annually and check for dust accumulation on heatsinks. The integrated brake transistor and chopper up to 11 kW require periodic verification of braking resistor integrity. With a power loss of 130 W at Ir / 8 kHz, enclosure ventilation must be sized accordingly. These measures, combined with the drive's overload capability of 1.8 x rated torque for 60 s, support reliable operation in cyclical load applications.
Product Support & Availability
AutoDCSTech supplies the E82EV222K4C200 with engineering-grade precision, ensuring each unit meets the verified specifications. In stock and ready to ship, this inverter is backed by specialist engineering support for configuration and integration queries. Contact AutoDCSTech with your exact requirements for precise matching.
Availability & Condition at AutoDCSTech
| Part Number | E82EV222K4C200 |
|---|