The Mitsubishi MR-J3-CV18K is a industrial automation component for industrial control and automation applications.
As servo-driven automation spread from simple positioning tasks to high-throughput production lines, engineers faced a new challenge: dissipating the energy that motors return to the drive during deceleration. The Mitsubishi MR-J3-CV18K power regeneration converter emerged from that evolution, turning braking energy back into usable DC power instead of heat. With a rated output power of 18 kW, it accepts 200-230 Vac input and provides 283-325 Vdc output at a rated current of 76 A.
What makes the MR-J3-CV18K suitable for regenerative applications?
This unit combines a wide input voltage window with a regulated DC output. Its 3-phase input design also supports 1-phase operation, giving integrators flexibility when retrofitting existing cabinets. Forced ventilation maintains thermal stability, and the IP20 rating permits installation in controlled industrial enclosures.
- Rated output power: 18 kW
- Rated input voltage: 200-230 Vac
- Input frequency: 50/60 Hz
- Rated output voltage: 283-325 Vdc
- Rated current: 76 A
- Input phases: 3-phase (also usable on 1-phase input)
- Cooling method: Forced Ventilation
- Protection rating: IP20
- Operating temperature range: 0 to +55°C
- Storage temperature range: -20 to +75°C
- Operating humidity range: 10 to 90% RH (Non-condensing)

How does the converter integrate into a servo system?
In a typical MELSERVO MR-J3 architecture, This unit sits between the AC supply and the DC bus, converting regenerated energy for reuse. Because the unit supplies a stable 283-325 Vdc link, it reduces reliance on braking resistors and improves overall energy efficiency. The 76 A rated current supports demanding duty cycles without derating under specified conditions.

Where should engineers focus during installation?
Mount the converter in an enclosure that respects the IP20 boundary and provides sufficient airflow for forced ventilation. Verify that the supply matches the 200-230 Vac range and that the 50/60 Hz frequency is stable. Keep ambient temperature within 0 to +55°C, and avoid condensing humidity above 90% RH. For 1-phase configurations, confirm wiring guidelines with Mitsubishi documentation before energizing.
What maintenance practices extend service life?
Periodic inspection of ventilation paths and fan operation is essential because forced cooling directly affects thermal performance. Check terminal torque and look for dust accumulation that could impede airflow. Store spare units within -20 to +75°C, and verify humidity remains non-condensing during storage. These steps help preserve the engineering-grade precision of the power stage over time.
Contact AutoDCSTech with your exact requirements for precise matching.
Availability & Condition at AutoDCSTech
| Part Number | MR-J3-CV18K |
|---|---|
| Availability | In Stock |
| Warranty | One Year |