Product Overview
The Allen-Bradley 1762-OW16 is a MicroLogix expansion module designed to add relay output capacity to MicroLogix 1100, 1200, and 1400 programmable logic controllers. This module provides sixteen relay contact outputs for energizing and de-energizing electrical loads, making it a versatile choice for discrete control applications. It operates on both AC and DC power, with an operating voltage range of 5-265V AC and 5-125V DC.

Technical Specifications Breakdown
Key parameters for the 1762-OW16 are listed below for quick reference:
| Feature | Specification |
|---|---|
| Module Type | Relay Output Module |
| Number of Outputs | 16 (AC/DC Relay) |
| Operating Voltage Range | 5-265V AC; 5-125V DC |
| Relay Contact Voltage Ratings | 24-125 VDC; 120-240VAC |
| Max. Current per Point | 2.5 A |
| Signal Delay | 10 ms |
| Heat Dissipation | 6.1 Watts |
| Shipping Weight | 0.63 pounds |
| Isolated Groups | 2 |
| Channels Per Group | 8 |
Industry Applications
The 1762-OW16 is well-suited for controlling discrete loads such as motors, solenoids, and lights in manufacturing and process industries. With its 16 relay outputs organized into two isolated groups, it can handle mixed AC/DC loads up to 2.5A per point. The module's 10 ms signal delay ensures reliable switching for most industrial sequences.

Installation & Setup Guidance
Mount the 1762-OW16 on a DIN rail or panel as per standard MicroLogix practice. Ensure the base controller (MicroLogix 1100, 1200, or 1400) is powered off before insertion. Connect wiring per the relay contact voltage ratings: 24-125 VDC or 120-240 VAC. Use surge suppressors across inductive loads to protect relay contacts from inrush currents. Verify that the total continuous current per module does not exceed 16A and per common does not exceed 8A.
Maintenance & Reliability
Periodically inspect relay contacts for wear, especially in high-cycle applications. Keep the module's IP20 enclosure free from dust and moisture. Ensure ambient temperature remains within the controller's specified range to prevent overheating. The module's heat dissipation of 6.1 Watts should be considered in cabinet thermal management.
Compatibility & Integration
This module is compatible with MicroLogix 1100 (up to 4 modules), MicroLogix 1200 (up to 6 modules), and MicroLogix 1400 (up to 7 modules). The two isolated output groups allow mixing of AC and DC loads on separate commons.
Selection Guide & Purchasing Advice
When selecting the 1762-OW16, verify your controller model and the required number of output points. For applications needing high-current or mixed-voltage control, this module offers flexibility with its 16 relay outputs. AutoDCSTech stocks this module and can advise on lifecycle status and availability. Contact us before ordering to confirm compatibility with your system.
Troubleshooting & Common Issues
If outputs fail to energize, check the relay contact voltage and ensure it matches the load. Verify that the module is properly seated on the DIN rail and that the bus connector is engaged. For intermittent operation, inspect for loose wiring or worn relay contacts. Always follow Allen-Bradley's wiring guidelines and use surge suppression for inductive loads to extend relay life.
Availability & Condition at AutoDCSTech
| Part Number | 1762-OW16 |
|---|---|
| Availability | In Stock |
| Condition | New |
| Warranty | One Year |
| Origin | US |