Product Introduction
When specifying a compact variable speed drive for a 0.75 kW three-phase asynchronous motor, engineers need exact electrical data and verified protection behavior. The ATV310H075N4E from Schneider Electric, part of the Easy Altivar 310 series, delivers a 380...460 V three-phase supply, 2.3 A maximum continuous output current at 380 V, and a 2.5 kVA apparent power rating at 460 V. This drive is engineered for precise control in pump, fan, and general machinery applications where space and reliability are critical.
The ATV310H075N4E integrates a 4-digit keypad with navigation and RUN/STOP buttons, supports Modbus RTU over a 2-wire RS-485 RJ45 port, and provides sensorless vector control with an internal speed loop. With no integrated EMC filter, an external filter is required to meet IEC/EN 61800-3, giving you flexibility to match the drive to your specific installation environment.

Key Features & Technical Specifications
- Supply voltage: 380...460 V AC, 50/60 Hz, three-phase, with maximum input current of 3.5 A at 380 V and 3.1 A at 460 V.
- Maximum continuous output current (In): 2.3 A at 380 V, at nominal 4 kHz switching frequency.
- Maximum transient current (60 s): 3.5 A at 380 V, supporting 150% starting torque at 3 Hz.
- Integrated EMC filter: None; an external EMC filter is required to meet IEC/EN 61800-3.
- Built-in communication: 1 RJ45 connector (2-wire RS-485) supporting Modbus RTU; no communication-module slot.
- Digital inputs: 4 logic inputs (LI1-LI4), 24 V, source or sink configurable, IEC/EN 61131-2 PLC level.
- Analog input: 1 software-configurable voltage (0...5 V or 0...10 V) or current (0...20 mA), 10-bit resolution, ±1% accuracy at 25 °C.
- Relay output: 1 relay output (R1) with 1 NO and 1 NC contact, 3 A maximum at 250 VAC resistive.
- Protection rating: IP20 (IP4X / IP40 on top with vent cover), pollution degree 2 per IEC/EN 61800-5-1.
- Operating temperature: -10...+55 °C without derating (Type B/C heavy duty); up to +60 °C with derating.
The ATV310H075N4E's 2.3 A continuous output current at 380 V provides a verified margin for 0.75 kW motors, while the 3.5 A transient current for 60 s ensures reliable starts under load. The integrated braking chopper terminals (PA/+ and PB) deliver >70% braking torque without an external resistor, or 150% with one, enabling precise deceleration control in high-inertia applications.
Applications & Use Cases
The ATV310H075N4E is engineered for three-phase asynchronous motors in variable-torque and constant-torque applications. Its U2/f pump law makes it particularly suitable for centrifugal pumps and fans, where energy savings are a priority. In HVAC systems, the drive's sensorless vector control maintains precise speed regulation under varying loads. For material handling conveyors, the 150% starting torque at 3 Hz ensures reliable breakaway. The integrated Modbus RTU port allows seamless integration into existing control networks, while the IP20 rating suits installation in protected cabinets. With an operating temperature range of -10...+55 °C without derating, the drive performs reliably in demanding industrial environments.

Installation & Setup
Mount the ATV310H075N4E according to Type A, B, or C per user manual EAV94277 p.21. Type A requires ≥10 mm free space each side with vent cover (IP20, IP4X top). Type B allows side-by-side mounting with vent covers removed. Type C requires ≥10 mm free space each side without vent cover. Power terminal tightening torque is 0.8-1.0 N·m for frames 037-U22, and control terminals require 0.5-0.6 N·m. Maximum motor cable length is 25 m shielded or 50 m unshielded at 4 kHz switching frequency; up to 100 m shielded or 200 m unshielded with a motor choke. For compliance with IEC/EN 61800-3, install an external EMC filter. An external line choke (VW3A455p) is recommended to reduce harmonic distortion.
Maintenance & Reliability
The fan is the only wearing part and can be replaced without tools, minimizing downtime. Routine inspection should include fan operation, terminal tightness, and cleaning of heatsink fins. The drive's protection functions—motor thermal protection by I²t calculation (trip above 118%), drive overtemperature with automatic switching-frequency reduction, output phase loss, output short-circuit, IGBT short-circuit, and underload detection—ensure safe operation. Operating temperature up to +60 °C with derating and altitude up to 3000 m with 1% current derating per 100 m above 1000 m support deployment in diverse environments. The ATV310H075N4E is part of the Easy Altivar 310 product line, with official product pages active as of 2026-10.
Compatibility & Integration
The ATV310H075N4E integrates via its built-in Modbus RTU port (2-wire RS-485, RJ45). It has no communication-module slot, so fieldbus integration requires an external gateway. For network integration, confirm gateway compatibility with your PLC or SCADA system. The drive's analog and digital I/O—including 1 analog input, 1 analog output, 4 logic inputs, 1 logic output, and 1 relay output—support direct connection to sensors and controllers. When wiring into fieldbus networks, an external gateway or connection module may be required; consult AutoDCSTech for precise matching of cables and gateways.
Product Support & Availability
In stock and ready to ship from AutoDCSTech, the ATV310H075N4E is backed by engineering-grade precision in every part. Contact AutoDCSTech with your exact requirements for precise matching and specialist engineering support.
Availability & Condition at AutoDCSTech
| Part Number | ATV310H075N4E |
|---|