330102-00-52-10-02-00: A 5.2 in Case for Deep-Holder Installations
The 5.2 in overall case length is what distinguishes this probe. On machines where the target surface sits deep inside the probe holder, a short-case probe either cannot reach or has to be gapped incorrectly to compensate — the 330102 with a 5.2 in case is the variant that reaches without modifying the holder.
Decoded against the published configuration data: 330102 = 3300 XL 8 mm proximity probe. 00 = unthreaded length 0 in. 52 = overall case length 5.2 in. 10 = total length 1.0 meter (3.3 feet). 02 = miniature coaxial ClickLoc connector. 00 = approval code 00.
Thread is 3/8-24 UNF, probe tip is polyphenylene sulfide (PPS) and the case is AISI 303 or 304 stainless steel. The PPS tip resists wear in high-speed applications where a softer tip would erode, and the stainless case tolerates the temperature profiles typical of turbine and compressor casings.
| Feature | Specification |
|---|---|
| Manufacturer | Bently Nevada |
| Brand | Bently Nevada |
| Part Number | 330102-00-52-10-02-00 |
| Manufacturer | Bently Nevada |
| Product No. | 330102-00-52-10-02-00 |
| Product Type | 3300 XL 8 mm Proximity Probe |
| Thread | 3/8-24 UNF |
| Unthreaded Length | 0 in |
| Overall Case Length | 5.2 in |
| Total Length | 1.0 meter (3.3 feet) |
| Connector | Miniature coaxial ClickLoc |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 stainless steel |
| Linear Range | 2 mm (80 mils) |
| Recommended Gap | -9 Vdc |
| Temperature Range | -52°C to +177°C. |
Case Length Against the Other 3300 XL 8 mm Probes
Case length is the mechanical dimension that decides whether a probe reaches its target surface. These are the comparable configurations in the same platform:
| 3301xx Part Number | Case / Length Configuration |
|---|---|
| 330101-00-08-05-02-00 | 3300 XL 8 mm platform — compare case length and thread against the probe being removed |
| 330101-00-08-05-02-05 | 3300 XL 8 mm platform — compare case length and thread against the probe being removed |
| 330101-00-08-05-12-CN | 3300 XL 8 mm platform — compare case length and thread against the probe being removed |
| 330101-00-08-10-01-CN | 3300 XL 8 mm platform — compare case length and thread against the probe being removed |
| 330101-00-08-10-02-00 | 3300 XL 8 mm platform — compare case length and thread against the probe being removed |
| 330101-00-08-10-02-05 | 3300 XL 8 mm platform — compare case length and thread against the probe being removed |
| 330101-00-08-10-02-CN | 3300 XL 8 mm platform — compare case length and thread against the probe being removed |
| 330101-00-08-10-11-00 | 3300 XL 8 mm platform — compare case length and thread against the probe being removed |
| 330101-00-08-10-11-CN | 3300 XL 8 mm platform — compare case length and thread against the probe being removed |
| 330101-00-08-20-02-05 | 3300 XL 8 mm platform — compare case length and thread against the probe being removed |
All Bently Nevada parts · Sensors & Instrumentation
When a Long Case Is the Wrong Choice
A longer case is only correct when the holder geometry calls for it. In a shallow holder an over-length probe bottoms out before reaching the specified gap, which produces erratic readings rather than a clean failure. Where the removed probe had a short case and the holder was not modified, the shorter-case variant is the right replacement — length is not an improvement, it is a fit.
Confirm three facts before ordering: thread standard (3/8-24 UNF), overall case length, and the gap the connected monitor expects. Recommended gap on this platform is -9 Vdc, approximately 1.27 mm (50 mils) for radial vibration monitoring.
Supply & terms: Stock status: In Stock · Condition: New · Warranty: One Year · Origin: US. Listed by AutoDCS Tech Parts Team · Last updated .
Availability & Condition at AutoDCSTech
| Part Number | 330102-00-52-10-02-00 |
|---|---|
| Availability | In Stock |
| Condition | New |
| Warranty | One Year |
| Origin | US |