When a machine builder needed to remove heat from a sealed enclosure without adding fan noise or dust ingress, the Lenze E82CV371K2C provided the answer. This 8200 vector frequency inverter uses cold-plate technology: the standard heatsink is replaced by a bare metal plate that mounts to a customer-side cooler. Consequently, heat leaves the cabinet through the cooling medium rather than the air inside the enclosure.
Key Specifications and Cold-Plate Thermal Design
The E82CV371K2C is rated for 0.37 kW typical motor power with a 4-pole three-phase asynchronous motor. Its output stage delivers 2.4 A nominal at an 8 kHz switching frequency, and it can supply 3.6 A for 60 seconds during periodic overload cycles. The supply accepts 1/N/PE AC 180 V -0% to 264 V +0% at 45 to 65 Hz, covering a wide range of single-phase networks. For thermal management, the cold plate dissipates 20 W of power loss with a thermal resistance Rth ≤ 1.5 K/W between cooler and cooling medium. The maximum permissible cooling-plate temperature is 75 °C.
| Parameter | Value |
|---|---|
| Rated motor power | 0.37 kW typical |
| Rated output current | 2.4 A at 8 kHz |
| Max. output current | 3.6 A for 60 s |
| Supply voltage | 1/N/PE AC 180 V -0% … 264 V +0%; 45 … 65 Hz |
| Operating temperature | -10 … +55 °C (derated by 2.5%/°C above +40 °C) |
| Protection rating | IP20 |

How Does This unit Handle Control and Communication?
Control is via V/f characteristic (linear or quadratic) and sensorless vector control, with an output frequency range of -650 to +650 Hz. The X3 control terminal strip provides 1 analog input, 1 analog output, 4 digital inputs, 1 digital output, and 1 relay output with a changeover contact rated 250 V AC / 3 A. An integrated brake transistor simplifies braking resistor connection. No fieldbus protocol is built in; instead, the FIF slot accepts plug-in function modules from the E82ZAF* family for network expansion.
Integration and Environmental Considerations
Because the cold plate requires a customer-side cooler, verify that the cooling circuit can maintain the plate below 75 °C under the 20 W dissipation. The inverter operates from -10 to +55 °C with 2.5%/°C derating above +40 °C. Storage temperature ranges from -25 to +60 °C, and relative humidity averages 85 % RH without condensation (climatic class 3K3 per EN 50178). The IP20 rating suits installation inside a protective cabinet. For fieldbus integration, confirm gateway and cable requirements with AutoDCSTech.

What Applications Suit This Cold-Plate Inverter?
This model is well suited to sealed cabinets, clean-room equipment, and mobile systems where air cooling is impractical. Typical uses include small conveyors, pumps, and fans driven by 0.37 kW motors. The cold-plate design also helps where ambient dust or humidity would clog a conventional heatsink.
Reliability and Maintenance
Periodically inspect the cooling-plate interface for corrosion or coolant flow reduction. Verify that the cooling medium temperature stays within limits. Because there are no fans, maintenance focuses on the thermal path rather than air filters. Keep the IP20 enclosure clean and dry.
Availability & Condition at AutoDCSTech
| Part Number | E82CV371K2C |
|---|---|
| Availability | In Stock |
| Warranty | One Year |