Product Introduction
The Lenze EVF9383-EVV060 is a three-phase frequency inverter from the 9300 vector series, built for high-power industrial drive duty. Its 400 kW rating — delivered through a master + slave parallel construction — places it in the upper tier of the series, where exact electrical specifications and verified thermal behaviour matter more than convenience features. The EVV060 variant adds an integrated brake transistor; the brake resistor itself is external. For engineers sizing a replacement or specifying a legacy 9300 vector drive, this record provides the precise parameters needed for a defensible selection decision.

Key Features & Technical Specifications
- Rated motor power 400 kW for a 4-pole asynchronous motor at 3 AC 400 V.
- Output current 750 A nominal at 2 kHz chopper frequency.
- Maximum output current 1125 A for 60 s, matching 150% rated torque for 60 s.
- Supply voltage 3/PE AC 340 to 456 V nominal, 45 to 65 Hz.
- Chopper frequency adjustable 1, 2 or 4 kHz.
- Control modes: U/f characteristic (linear/square), vector control, sensorless speed control.
- Integrated brake transistor in the EVV060 variant; brake resistor external.
- Power loss 10 kW; internal fan with bottom-to-top airflow.
- Protection rating IP20; operating temperature 0 to +50 °C.
- Dimensions 1145 × 1050 × 436 mm; weight 400 kg.
The most consequential specification here is the 1125 A short-time current. A 150% overload window of 60 s is what allows the drive to ride through the acceleration peaks of high-inertia loads — large fans, centrifuges, heavy conveyors — without tripping. That headroom is not a marketing figure; it is the verified basis for motor and cable sizing on this frame size.
Comparison with Alternative Drive Configurations
When evaluating the EVF9383-EVV060 against other high-power drive options, the relevant axes are overload capability, braking architecture, and communication flexibility. The table below compares this unit with typical alternatives in the same power class.
| Parameter | EVF9383-EVV060 (9300 vector) | Typical 400 kW drive, no brake transistor | Modular multi-axis system |
|---|---|---|---|
| Overload | 150% for 60 s (1125 A) | 150% for 60 s, model-dependent | Varies by axis module |
| Braking | Integrated brake transistor, external resistor | External braking unit required | Regenerative or external, module-dependent |
| Fieldbus | Pluggable via AIF (X1); CAN system bus (X4) | Often fixed or optional card | Backplane-based |
| Footprint | Single parallel master + slave enclosure | Single enclosure | Multiple cabinets |
The integrated brake transistor removes one external component from the panel, which simplifies wiring and reduces enclosure space. The trade-off is that the brake resistor must still be specified and mounted externally, with its thermal dissipation accounted for in the cabinet design.

Applications & Use Cases
The 400 kW rating and 150% overload window suit continuous-process loads with high starting torque. In fan and pump applications, the U/f square characteristic reduces energy consumption at part load while the sensorless speed control mode maintains stable operation without an encoder. For centrifuge and decanter duty, the vector control mode holds torque at low speed, and the integrated brake transistor enables controlled deceleration by dissipating regenerated energy in the external resistor. Heavy conveyor and mixer drives benefit from the 1125 A short-time current during start-up, where breakaway torque can exceed running torque substantially. In all these cases, the IP20 protection rating means the drive must be installed in a suitable enclosure — it is a cabinet-mount device, not a field-mounted one.
Installation & Setup
Mount the unit vertically to preserve the bottom-to-top airflow path; the internal fan is sized for this orientation and for the 10 kW power loss that must be removed from the enclosure. Verify that the supply is within the 3/PE AC 340 to 456 V, 45 to 65 Hz window before energisation. Because the construction is master + slave in parallel, observe the manufacturer's parallel-wiring requirements for the motor cable and ensure equal cable lengths between the two units and the motor terminals. The AIF interface (X1) accepts a pluggable fieldbus module; no fieldbus is integrated as standard, so the module must be selected and fitted before network commissioning. The CAN system bus on X4 is available for drive-to-drive coordination.
Maintenance & Reliability
Schedule inspection of the internal fan and heatsink at intervals consistent with the installation environment; the bottom-to-top airflow path draws dust through the enclosure, and a restricted airflow path will raise internal temperatures toward the +50 °C operating limit. Check the external brake resistor for thermal degradation, particularly in applications with frequent deceleration cycles. The 10 kW power loss figure is the basis for enclosure cooling calculations — verify that the cabinet ventilation or air-conditioning capacity retains margin as filters load up. Storage temperature range is -20 to +60 °C, which covers typical warehouse conditions but not outdoor or unheated sites in extreme climates.
Compatibility & Integration
The 9300 vector series is a legacy platform. Lenze lists the 9300 within the i950 migration set, with a documented migration path via the i950 PROFIBUS module and L_ICIP library. There is no drop-in same-order-code replacement, so a migration project must account for mechanical footprint, wiring, and parameter remapping. For existing installations, fieldbus connectivity is achieved by fitting a module to the AIF interface; supported modules per official Lenze product information include LECOM-A/B, PROFIBUS DP, CANopen, DeviceNet, INTERBUS and LON.
Integration Note: Wiring into fieldbus networks such as PROFIBUS DP or DeviceNet may require an external gateway or connection module depending on the network architecture. Confirm cable types and gateway compatibility with the supplier before commissioning.
Product Support & Availability
AutoDCSTech supplies the EVF9383-EVV060 with verified specifications traceable to official Lenze documentation. In stock and ready to ship. Contact AutoDCSTech with your exact requirements for precise matching.
Availability & Condition at AutoDCSTech
| Part Number | EVF9383-EVV060 |
|---|