What is the 170CPS11100 power supply adaptor?
The Schneider Electric this controller is a processor adaptor power supply for the Modicon Momentum automation platform. It converts an adjustable 120 to 230 Volts AC input into a stable 24 Volts DC output at 0.7 Amperes. This module delivers engineering-grade precision for Momentum-based control systems.

Key specifications and performance
- Input voltage: 120 to 230 Volts AC, adjustable by jumper.
- Output voltage: 24 Volts DC.
- Output current: 0.7 Amperes nominal.
- Fuse rating: 0.63 Amperes at 120 Volts, 0.315 Amperes at 230 Volts.
- Operating temperature: 0 to 60°C in non-condensing environments.
- Humidity tolerance: 5% to 95% relative humidity without condensation.
- Operating altitude: Up to 6,561.68 feet (2,000 meters).
- Terminal connection: Terminal strip connector.
- Local signalling: 1 LED indicator (RUN).
- Weight: 0.626 lb (0.284 kg).
These verified specifications ensure the adaptor meets exact application requirements. The jumper-adjustable input simplifies inventory across voltage standards, while the 0.7 Amperes output supports continuous processor loads.
How does this controller integrate into Momentum systems?
this controller mounts directly within Modicon Momentum assemblies, using a terminal strip connector for secure wiring. Its single RUN LED provides immediate visual confirmation of module operation. The adaptor operates from 50 to 60 Hertz, matching common industrial supply frequencies. For integration into networked Momentum architectures, confirm gateway and cabling requirements with AutoDCSTech.

What are typical applications for this power supply adaptor?
This adaptor suits industrial control cabinets where a reliable 24 Volts DC rail is needed for Momentum processors. It performs in ambient temperatures from 0 to 60°C and tolerates humidity from 5% to 95% without condensation. The 0.7 Amperes output current is well-matched to processor adaptor loads. Additionally, the altitude rating of up to 6,561.68 feet (2,000 meters) supports installations at higher elevations. The adjustable input voltage allows the same part to serve 120 Volts AC and 230 Volts AC environments, reducing spares complexity.
How to maintain reliable operation
Periodically inspect terminal strip connections for tightness and verify the RUN LED indicates normal operation. Ensure the enclosure remains non-condensing and within the 0 to 60°C ambient range. Because the fuse ratings are 0.63 Amperes at 120 Volts and 0.315 Amperes at 230 Volts, always replace fuses with the exact specified values. Store the unit between -25 and 70°C in a dry environment. These practices support long-term, engineering-grade precision in your Momentum system.
Availability & Condition at AutoDCSTech
| Part Number | 170CPS11100 |
|---|