I/O Modules PLC & I/O Modules

9905-204 DSM Synchronizer Module 125 V dc 115/230 V AC

On Request
Brand: Woodward
Product No. 9905-204

Woodward 9905-204 DSM synchronizer module operates on 125 V dc and supports 115/230 V AC systems with a small sync window and 1% voltage matching.

Contact Us
Fast Worldwide Shipping
100% Genuine Products
Warranty Included

Product Description

The Woodward 9905-204 is a DSM Synchronizer Module 115/230v-AC for industrial control and automation applications.

When paralleling a generator to a live bus, engineers face a narrow synchronization window: the voltage difference must be held to 1% while the phase angle and frequency converge. The Woodward 9905-204 DSM Synchronizer Module addresses this challenge with digital speed matching and a small sync window, operating from a 125 V dc power supply.

What defines the Woodward this module synchronizer module?

This module belongs to the Woodward 9900 series and is configured as a DSM Synchronizer Module for 115/230 V AC systems. Its digital speed matching function compares incoming generator frequency with bus frequency, while voltage matching is specified at 1%. The small sync window constrains the permissible phase difference for breaker closure. Power is drawn from a 125 V dc supply, and the module operates across an ambient temperature range of -35 to 65 degrees Celsius.

Figure 1: Front view of the Woodward 9905-204 DSM Synchronizer Module 115/230v-AC showing its physical design and enclosure.

Key specifications at a glance

  • Power supply voltage: 125 V dc
  • Product type: DSM Synchronizer Module 115/230 V AC
  • Series: Woodward 9900
  • Voltage matching: 1%
  • Sync window: small
  • Operating temperature: -35 to 65 degrees Celsius
  • Board size: 33.0 cm high x 17.8 cm
  • Size: 8.25 cm high x 4.27 cm

How does the 125 V dc input affect synchronization reliability?

A stable 125 V dc control supply is fundamental to consistent synchronizer operation. This module derives its internal logic from this rail, so voltage dips or ripple can disturb speed and voltage matching calculations. Therefore, verify that the station battery or dc source maintains 125 V dc within the tolerances defined by the plant design. Because the module operates down to -35 degrees Celsius, it suits installations in unheated enclosures or outdoor cabinets where temperature swings are expected.

Figure 2: Technical layout and connection details for the Woodward 9905-204 DSM Synchronizer Module 115/230v-AC.

Where is this synchronizer module applied?

Typical installations include generator control panels, cogeneration plants, and marine power management systems where 115/230 V AC buses require controlled paralleling. The small sync window reduces the risk of closing the breaker outside acceptable phase limits. In addition, the 1% voltage matching threshold helps limit reactive current surges at the moment of synchronization. For systems with multiple generators, the digital speed matching function supports repeatable breaker closure sequences.

Installation and integration considerations

Mount the module using the board dimensions of 33.0 cm high x 17.8 cm as a guide for panel layout. Ensure the 125 V dc supply is isolated and fused according to the panel design. Because synchronization involves both voltage and frequency references, route signal wiring away from high-current conductors to reduce noise coupling. Confirm terminal assignments and wiring details against the official Woodward documentation before energizing the module.

Frequently asked questions

What is the power supply requirement for the Woodward this module?

The Woodward this module requires a 125 V dc power supply voltage. This input powers the module's digital speed matching and voltage matching functions.

What is the operating temperature range of this module synchronizer?

The Woodward this module operates from -35 to 65 degrees Celsius, making it suitable for a range of industrial environments.

What does the 1% voltage matching specification mean?

The Woodward this module performs voltage matching at 1%, meaning the synchronizer compares generator and bus voltages within that threshold before permitting breaker closure.

What are the physical dimensions of this module module?

The board size is 33.0 cm high x 17.8 cm, and the module size is 8.25 cm high x 4.27 cm. Use these dimensions for panel space planning.

Contact AutoDCSTech with your exact requirements for precise matching.

· Last updated:

Availability & Condition at AutoDCSTech

Part Number9905-204

Written by , Sales Engineer.

Wayne is a sales engineer with 15 years of experience in the industrial automation industry.

Frequently Asked Questions

Technical Specifications

Product Type I/O Modules
SKU / Part Number 9905-204

Latest News

View All →