I/O Modules PLC & I/O Modules

Allen-Bradley 2711P-B12C10D6 PanelView Plus 1250 HMI Terminal

On Request
Brand: Allen-Bradley
Product No. 2711P-B12C10D6
Model 2711P-B12C10D6
Origin US
Condition New
Warranty One Year

The Allen-Bradley 2711P-B12C10D6 HMI terminal features a 12.1-inch TFT color LCD, touchscreen and keypad, dual power options, and robust communication interfaces for industrial automation.

Contact Us
Fast Worldwide Shipping
100% Genuine Products
Warranty Included

Product Description

Technical Specifications Breakdown

Key parameters for the 2711P-B12C10D6 are listed below for quick reference:

Feature Specification
Manufacturer Allen Bradley
Series PanelView Plus 1250
Part Number 2711P-B12C10D6
Product Type HMI terminal
Input Mechanism Touchscreen + keypad
Screen Technology 12.1" TFT color LCD
Pixel Matrix 800 × 600 pixels
Supply Voltage 24 V DC (11 W) or 85–264 V AC
Max. Power 70 W peak / 39 W nominal
Battery Life ≥4 years at 25 °C
Clock Accuracy ±2 min/month (battery-backed)
Operating Temperature 0 °C to 55 °C
Heat Dissipation 240 BTU/hr
Backlight CCFL, ≥50 000 hr life
Processor & RAM CE-class CPU, 128 MB RAM
Storage CompactFlash slot, up to 512 MB
Communication Ethernet 10/100, RS-232, ControlNet

Installation and Setup Guidance

When integrating the 2711P-B12C10D6 into your system, follow these practical steps:

  • Power Supply: Ensure the power source matches one of the accepted inputs (24 V DC or 85–264 V AC). Verify the voltage before connecting to avoid damage.
  • Mounting: Mount the unit in a location that allows adequate airflow for heat dissipation (240 BTU/hr). Avoid enclosing it in a sealed panel without proper ventilation.
  • Communication Setup: For Ethernet 10/100 connections, use a shielded cable to minimize electromagnetic interference. For ControlNet, follow the standard trunkline and tap guidelines.
  • Storage: Insert a CompactFlash card (up to 512 MB) for application storage and data logging. Ensure the card is formatted correctly before use.

Maintenance and Reliability Tips

To maximize the lifespan of the 2711P-B12C10D6, adopt a proactive maintenance routine:

  • Backlight: The CCFL backlight is rated for ≥50,000 hours. Monitor brightness and replace the backlight when it dims to avoid screen visibility issues.
  • Battery: The internal battery supports the clock for at least 4 years at 25 °C. Replace the battery before it expires to maintain accurate time-stamping.
  • Cleaning: Use a soft, dry cloth to clean the touchscreen. Avoid abrasive cleaners that can damage the surface.
  • Environmental Checks: Keep the operating temperature within 0 °C to 55 °C. Excessive heat can reduce component life.

Why the Allen-Bradley 2711P-B12C10D6 HMI Terminal Stands Out

For maintenance engineers, a dependable human-machine interface is critical. The Allen-Bradley 2711P-B12C10D6 from the PanelView Plus 1250 series delivers a robust combination of visual clarity, flexible input options, and industrial-grade connectivity.

Figure 1: Front view of the Allen-Bradley 2711P-B12C10D6 industrial automation component showing its physical design and enclosure.

Built for Real-World Industrial Environments

The 2711P-B12C10D6 is designed to handle demanding applications. Its 12.1-inch TFT color LCD with 800 × 600 pixel resolution provides clear, readable screens even in low-light conditions. The dual-input capability—accepting either 24 V DC or 85–264 V AC—offers flexibility in power infrastructure, simplifying installation in existing plants. With a wide operating temperature range of 0 °C to 55 °C, this terminal can be deployed in various manufacturing settings, from assembly lines to process control stations.

Figure 2: Technical layout and connection details for the Allen-Bradley 2711P-B12C10D6 industrial automation component.

Compatibility and Integration

The 2711P-B12C10D6 offers versatile communication options: Ethernet 10/100 for high-speed data exchange, RS-232 for legacy device connectivity, and ControlNet for real-time control networks. This makes it compatible with a wide range of PLCs and industrial systems, including Allen-Bradley controllers. The CE-class CPU and 128 MB RAM ensure smooth operation of complex HMI applications.

Selection and Purchasing Advice

When selecting the 2711P-B12C10D6 for your project, consider your specific application requirements. If you need a robust HMI with flexible power options and multiple communication protocols, this model is an choice. AutoDCSTech offers this unit and can provide guidance on availability and lifecycle status. Contact AutoDCSTech to verify current stock and ensure the product meets your operational needs.

· Last updated:

Availability & Condition at AutoDCSTech

Part Number2711P-B12C10D6
AvailabilityIn Stock
ConditionNew
WarrantyOne Year
OriginUS

Frequently Asked Questions

Technical Specifications

Product Type I/O Modules
SKU / Part Number 2711P-B12C10D6
Model 2711P-B12C10D6
Country of Origin US
Condition New
Warranty One Year
Stock Status On Request
Instruction Manual 1785850407-Allen-Bradley_2711P-B12C10D6_Manual

Latest News

View All →