Lenze E94P040T4NEM is an encoder-based PositionServo Model 940 servo controller in the 480 VAC class, rated for 4 A nominal continuous output current. The unit accepts a three-phase drive input of 320 … 528 VAC at 50/60 Hz nominal, making it suitable for direct operation on 480 VAC class supplies.
What are the input and output ratings of the E94P040T4NEM?
The drive input spans 320 … 528 VAC, three-phase, 50/60 Hz nominal. Continuous output current is 4 A rms nominal, while peak output current reaches 12 A rms maximum. Overload is adjustable up to 300 % of the continuous rating at 8 kHz for 2 s, or 250 % at 16 kHz for 2 s. Continuous power is published as 800 W at 240 VAC. Input power consumption is not listed as a separate rated value by the manufacturer.

How does isolation and I/O structure support system integration?
All digital channels are optically isolated. The controller provides 12 digital inputs rated 5 … 24 VDC and 4 digital outputs rated 5 … 24 VDC at 100 mA, configured as optically isolated open collector. Two analog inputs and one analog output are available for reference and feedback signals. An encoder input accepts frequencies up to 2 MHz, with one standard encoder channel and an optional resolver input at 12-bit resolution.
Technical specifications
- Drive input: 320 … 528 VAC, 3-phase, 50/60 Hz nominal (480 VAC class unit)
- Continuous output current: 4 A nominal (rms)
- Peak output current: 12 A maximum (rms)
- Continuous power: 800 W @ 240 VAC
- Digital inputs: 12 (5 … 24 VDC, optically isolated)
- Digital outputs: 4 (5 … 24 VDC @ 100 mA, optically isolated open collector)
- Analog inputs / outputs: 2 / 1
- Encoder input: Up to 2 MHz (1 standard; optional resolver input 12-bit)
- Dimensions (H×W×D): 190 × 95 × 190 mm
- Weight: 1.9 kg

Which communication interfaces are available?
An RS232 (PPP) port is built in on board. Optional interfaces include Ethernet TCP/IP, RS485 (PPP or Modbus RTU Slave), and CANopen at 250/500/1000 kBaud. Protocol support therefore covers RS232 PPP as standard, with optional Modbus RTU, CANopen, and Ethernet TCP/IP. Fieldbus interfaces are added through option modules for communication expansion. When wiring into such networks, an external gateway or connection module may be required; confirm cable and gateway requirements with AutoDCSTech.
How should the controller be installed for reliable thermal performance?
Operating temperature is 0 … +40 °C, and storage temperature is -10 … +70 °C. Relative humidity must remain 5 … 90 % non-condensing. The unit tolerates vibration of 2 g across 10 - 2000 Hz. Site altitude is up to 1500 m, with derating of 1 % per 300 m above 1500 m. Temperature drift is 0.1 % per °C rise. The protection rating is not published in the PositionServo 940 specifications, so the enclosure must be protected from dust and moisture by the panel design.
For precise matching of this controller to your motion application, contact AutoDCSTech with your exact requirements.
Availability & Condition at AutoDCSTech
| Part Number | E94P040T4NEM |
|---|---|
| Availability | In Stock |
| Warranty | One Year |