Schneider Electric's research arm published a 44-page cost model, not a product launch. The report finds total electricity-system costs 10% below today's benchmark at current world-average solar and battery costs, and up to 40% below at costs projected for the 2030s — but only when new electricity demand grows alongside distributed generation.
- The document: System Costs of Electricity: A New Baseline for the 21st Century Economy, Schneider Electric Research Institute (SERI), published 10 November 2026, 44 pages, DOI 10.58284/SE.SRI/YCOY9984.
- The range: 10% is today's world-average result; 40% is the upper bound under 2030s cost projections. The United States currently sits about 20% above the benchmark, not below it.
- The venue: COP31 runs in Antalya, Türkiye, from 9 to 20 November 2026. It is not in Azerbaijan. The research release is datelined Vienna, and neither the release nor the report describes an official COP31 side event.
- The scenarios: 40,500 runs are modelled system configurations, not industrial microgrid projects or customer sites. Factories are one of three load archetypes, and the report says industry benefits least.
- The technology: no storage converter, PCS or controller product is named. The "control algorithm" is the model's own dispatch logic, not a shipped Schneider product.
- The gaps: no project capex, payback, discount rate or retail-tariff schedule is published, so the study cannot underwrite a specific plant investment.
What did Schneider Electric publish for COP31?
The Schneider Electric Research Institute published System Costs of Electricity: A New Baseline for the 21st Century Economy on 10 November 2026. The 44-page modelling report compares the levelised cost of rooftop solar and batteries with the fixed and variable cost of the central grid, rather than announcing a product or a customer deployment.
The report is a cost-arithmetic exercise built on a conceptual system. It does not model power flows, protection coordination or a real network. That distinction matters for anyone quoting its percentages as an engineering result.
| Attribute | Detail |
|---|---|
| Full title | System Costs of Electricity: A New Baseline for the 21st Century Economy |
| Publisher | Schneider Electric Research Institute (SERI) |
| Author | Vincent Petit |
| Publication date | 10 November 2026 |
| Length | 44 pages, including Appendix A on methodology |
| DOI | 10.58284/SE.SRI/YCOY9984 |
| Model | Total System Costs (TSC), implemented as a system-cost simulator in R |
| Scenario count | 40,500 scenario runs |
| Benchmark | US$160 per MWh excluding tax: US$90 generation (45% fixed) plus US$70 grid (85% fixed) |
Was COP31 held in Azerbaijan — or was this a COP31 launch?
COP31 is being held in Antalya, Türkiye, from 9 to 20 November 2026, under President Murat Kurum, with Australia's Chris Bowen as President of Negotiations. Azerbaijan hosted COP29 in Baku in 2024. The Schneider release was issued on the second day of COP31, but it carries a Vienna dateline and is not described as an official COP31 event.
Two separate Schneider releases went out on 10 November 2026. One announces the research itself and is datelined Vienna, Austria. The other sets out the company's COP31 programme in Antalya and cites the research as supporting evidence. That second release lists Schneider's hosted events at the French Pavilion, including three sessions on 10 November, but it does not present the report as a COP31 side event or a Presidency deliverable.
So the accurate description is: a global research publication dated to the opening days of COP31, promoted alongside the company's COP31 programme. Calling it "Schneider's COP31 report" is defensible shorthand. Calling it a report "released in Baku at COP31" is not.

What do the 10% and 40% figures actually measure?
Both figures measure Total System Costs per megawatt-hour against a US$160/MWh benchmark. Ten percent is the lowest modelled result at today's world-average installed costs for rooftop solar and batteries. Forty percent is the upper bound at installed costs projected for the 2030s. Neither figure is a factory's electricity bill.
The model adds three cost blocks: the levelised cost of rooftop PV, the levelised cost of storage for batteries, and the fixed plus variable cost of the central system. Savings come from two mechanisms. Substitution is the larger one: every megawatt-hour produced and consumed on site avoids the delivered grid price. Dilution is the smaller one: batteries flatten each asset's load curve, freeing grid headroom that new demand can later fill.
| Cost case | Result versus US$160/MWh benchmark | What drives the result |
|---|---|---|
| Current world-average installed costs | 10% below, about US$145/MWh | Today's rooftop PV and battery costs outside the United States |
| Projected 2030s installed costs | 40% below, about US$94/MWh | Lower installed costs combined with growing electrified demand |
| Current United States | About 20% above, roughly US$191/MWh | Residential solar installed at roughly three times the world average |
The dollar values above appear in Schneider's own web summary of the report; the PDF states the benchmark and the percentage changes, with the absolute values shown in exhibits. Across different load profiles and system mixes, the optimal result varies by 4% to 17%, which the authors present as evidence that the direction of the finding is robust.
Do the 40,500 scenarios apply to factories?
No, not in the way the phrase "40,500 industrial microgrid simulations" suggests. The runs are conceptual system configurations built from three load archetypes — residential, service and industrial — combined with different system mixes, DER arrangements and cost levels. A factory is one input to the aggregate, not the subject of 40,500 separate plant studies.
The report is explicit that industry gains least. Industrial load is comparatively flat across the day, with lower demand at night, which leaves less peak for a battery to shave. Industry also has less physical potential for on-site DER deployment than a large office or a residential rooftop. The result is a narrower band of benefit, not a headline 40%.
| Load archetype | Daily shape | What the report says |
|---|---|---|
| Residential | Morning and evening double peak | Benefits from the transition, but under current US costs bears a higher cost because of DER installation costs |
| Service and office | Inverted U with a daytime peak | Consistently the lowest-cost archetype, because daytime demand tracks solar output |
| Industrial | Flat demand, lower at night | Benefits least; lower DER potential and flat load limit substitution. The illustrative industry case runs from US$142/MWh with a 2-hour battery to US$178/MWh when other segments choose differently |
That US$142 to US$178 spread is the most useful industrial number in the document, and it is conditional. The industry asset only reaches the low end if service buildings select a 2-hour battery and residential buildings select a 4-hour battery. If the other segments deploy no batteries, the industrial cost rises to US$178/MWh. A plant's outcome depends on decisions made outside its fence line.
What does the model include, and what does it leave out?
The model includes rooftop PV at levelised cost, batteries at levelised cost of storage, and central-grid fixed and variable costs, with surplus solar curtailed rather than exported. It does not publish project capex, payback, internal rate of return, a discount rate or the retail-tariff schedule behind each archetype, so it cannot be used to size or finance a specific installation.
| Included in the published model | Not published, or explicitly outside the model |
|---|---|
| Levelised cost of rooftop PV and levelised cost of storage for batteries | Project capital cost, payback period or IRR for any site |
| Fixed and variable central-system costs, anchored to US$160/MWh | The discount rate used to levelise costs |
| Backfill of freed grid headroom by new demand such as EVs, heat pumps and data centres | The retail-tariff schedules that drive geographic differences |
| Curtailment of excess solar, with no reinjection to the grid | Export payments or feed-in-tariff revenue |
| Three cost levels, two system mixes and electrified versus non-electrified heating profiles | Resilience, outage cost or power-quality value |
The curtailment assumption deserves emphasis. A factory that oversizes its roof without matching storage does not get paid for the surplus in this model; the energy is simply lost. That pushes the economics toward right-sizing generation against self-consumption rather than maximising installed capacity.
Which circulating claims does the report not support?
Four claims fail against the source. COP31 is not in Azerbaijan. The 40,500 runs are not industrial microgrid simulations. No storage converter or controller product is named. And 40% is a 2030s upper bound, not a present-day factory result. The defensible reading is a 10% to 40% system-cost range that depends on cost trajectories and demand growth.
| Claim in circulation | What the source actually says | Verdict |
|---|---|---|
| "COP31 in Azerbaijan" | COP31 is in Antalya, Türkiye, 9–20 November 2026. Azerbaijan hosted COP29 in Baku in 2024. | False |
| "40,500 industrial microgrid simulations" | 40,500 conceptual system scenarios across load archetypes, system mixes and cost levels. | Misstated |
| "Cuts electricity costs by 40%" | Up to 40% by the 2030s at projected costs; 10% at today's world-average costs. | Needs the qualifier |
| "Factory per-kWh cost falls 10–40%" | The metric is system-level Total System Costs; industry benefits least, with an illustrative US$142–178/MWh range. | Not supported as stated |
| "Smart coordination algorithm and industrial-grade storage converter" | The model uses a DER dispatch algorithm. No converter, PCS or named product appears in the report. | Not in the report |
| "40,500 customer sites" | The figure counts scenario runs, not sampled customers or installed systems. | False |
| "0.8% of GDP" | Additional income of 0.15–0.8% of GDP, with 0.8% reached in the 2030s. | Supported with the date caveat |
Where does battery duration change the answer?
Battery duration is the single largest swing factor in the study. Under world-average costs, a mismatch in battery duration across asset types can push total system costs from 10% below the benchmark to 35% above it. Under 2030s costs the same modelling choice moves the result from 40% below to 3% above.
The mechanism is aggregation. Each archetype is optimised separately, but the system cost depends on what all of them do together. A 2-hour battery that suits a flat industrial load does not produce the same system profile as a 4-hour battery on a residential site. When those choices diverge, the aggregate load curve is worse than the sum of the individual savings, and the fixed-cost dilution effect weakens.
The report also models three transition paths. Growing demand before DERs pushes costs to about US$173/MWh by 2035. Deploying DERs before demand pushes costs to about US$168/MWh around 2030 before they fall. Moving both together peaks lower, at about US$163/MWh, and declines to about US$105/MWh by 2050. Europe is placed closer to the DER-first path; some US states resemble the demand-first path.
What should an industrial energy team take from this?
Treat the study as a system-level signal, not a business case. It supports the direction of travel for on-site solar plus storage, and it identifies battery sizing, load shape and deployment sequencing as the variables that decide outcomes. It does not supply the capex, tariff or payback data needed to approve a project at a specific plant.
Three practical checks follow from the report's own structure.
First, compare your load shape with your generation shape. An office with a midday peak matches solar output. A flat industrial process does not, which is why the report places industry at the weaker end. If your plant runs three shifts at constant load, self-consumption from a rooftop array will be lower than the nameplate ratio suggests.
Second, size storage against the tariff, not against the array. The report treats demand charges and time-of-use rates as policy levers that flatten the load curve, but it does not publish the tariff schedules behind its archetypes. The value of a battery at your site depends on your own demand-charge structure and peak windows, which the study cannot tell you.
Third, separate the layers of equipment. A grid-connected battery system, a plant-level controller and a 24 V DC backup module are different products with different failure modes and different procurement paths. A DC battery control module such as the ABL8BBU24200 battery control module supports control-power ride-through; it is not grid storage and should not be counted toward a DER business case.
Where the study stops, integration work begins. The plant control layer that coordinates loads and exchange with the grid is typically built on controllers such as Modicon M580 processor modules, with substation data exchanged through IEC 61850 communication modules. The distribution layer — the breakers and protection that carry the resulting load — is a separate specification; a PowerPact J 225 A moulded-case breaker is the kind of item that gets sized from the single-line diagram, not from a system-cost study.
None of those products is named in the SERI report, and none of them is validated by it. They are the implementation layer that the report deliberately leaves out. If you are assembling that layer, the Schneider Electric automation parts and module index is a reasonable starting point for part numbers; for a project-specific review, send us the tariff structure and load profile rather than the headline percentage.
Frequently asked questions
Where was COP31 held in 2026?
COP31 is being held in Antalya, Türkiye, from 9 to 20 November 2026, according to the UNFCCC. Türkiye's Murat Kurum is President of COP31 and Australia's Chris Bowen is President of Negotiations. Azerbaijan hosted COP29 in Baku in 2024, which is the likely source of the confusion in some secondary coverage.
Did Schneider Electric launch this report at COP31?
The research release is dated 10 November 2026, the second day of COP31, but it is datelined Vienna, Austria. A separate Schneider release the same day sets out the company's COP31 programme in Antalya and cites the report. Neither document describes the report as an official COP31 side event or a Presidency output.
Does the report prove a 40% cut in factory electricity bills?
No. The 40% figure is the upper bound of Total System Costs reduction under installed costs projected for the 2030s, at system level. It is not a factory bill reduction, and the report states that industry benefits least among its three load archetypes because industrial load is flat and on-site DER potential is lower.
What is the difference between the 10% and 40% figures?
They are the same model run at different cost assumptions. At today's world-average installed costs for rooftop solar and batteries, the lowest modelled system cost is 10% below the US$160/MWh benchmark. At 2030s projected costs, it is 40% below. The US is currently about 20% above the benchmark because residential solar costs roughly three times the world average to install.
What are the 40,500 scenarios?
They are conceptual system configurations, not customer sites or individual microgrids. The model combines residential, service and industrial load profiles with different system mixes, DER penetration levels and cost cases, and runs each configuration through a system-cost simulator. The report describes the underlying system as conceptual rather than a real physical network.
Does the report name a battery converter or microgrid controller?
No. The report refers to a control algorithm that minimises peak demand and flattens each asset's load profile, but that algorithm is part of the model, not a named product. No power conversion system, inverter or commercial controller appears in the document. Claims that the study validates a specific storage converter are not supported by the source.
How much can an industrial site save?
The report does not give a single industrial saving. Its illustrative industry case ranges from US$142/MWh with a 2-hour battery, when service and residential assets also choose specific battery durations, to US$178/MWh when the other segments deploy no batteries. A plant's result depends on its load shape, tariff and the choices made by other grid users.
Does the report give payback or capital cost?
No. The report publishes levelised costs, the US$160/MWh benchmark and percentage changes, but no project capex, payback period, internal rate of return or discount rate. It also does not publish the retail-tariff schedules behind its geographic differences. Those gaps mean the study cannot be used on its own to approve or finance a specific installation.
Why does battery duration matter so much?
Because system cost depends on the combined load curve, not on each site's savings in isolation. Under world-average costs, a mismatch in battery duration across asset types can move total system costs from 10% below the benchmark to 35% above it. Under 2030s costs, the same choice moves the result from 40% below to 3% above.
Sources
- Schneider Electric Research Institute: System Costs of Electricity — A New Baseline for the 21st Century Economy
- Full report PDF (44 pages, DOI 10.58284/SE.SRI/YCOY9984)
- Schneider Electric press release, 10 November 2026 (Vienna dateline)
- Schneider Electric at COP31: programme release, 10 November 2026
- UNFCCC: COP31 in Antalya, Türkiye, 9–20 November 2026
- UNFCCC: COP29 in Baku, Azerbaijan, 2024
Related components
- Schneider ABL8BBU24200 Battery Control Module for Reliable Power Management
- Schneider BMEP584040 Modicon M580 Processor Module – Standalone Controller
- Schneider BMXRMS004GPF Memory Card for Modicon M580 ePAC
- Schneider BMENOC0321 Modicon M580 Ethernet Communication Module
- Schneider BMEH584040 Redundant Processor Module for Modicon M580
- Schneider BMENOC0301 Modicon M580 Ethernet IP/Modbus TCP Communication Module
Browse by brand: Schneider Electric
More in News
Looking for COP31?
Browse genuine COP31 units, specifications, and pricing — or request a quote from our automation specialists.
View COP31 Products & Get a Quote →